Anmelden

University Hospitals KU Leuven

4 ARTICLES PUBLISHED IN JoVE

image

Medicine

A Novel Surgical Approach for Intratracheal Administration of Bioactive Agents in a Fetal Mouse Model
Marianne S. Carlon *1, Jaan Toelen *2, Marina Mori da Cunha 2, Dragana Vidović 1, Anke Van der Perren 3, Steffi Mayer 2, Lourenço Sbragia 2, Johan Nuyts 4, Uwe Himmelreich 5, Zeger Debyser 1, Jan Deprest 2
1Molecular Virology and Gene Therapy, KU Leuven, 2Department of Woman and Child, KU Leuven, 3Neurobiology and Gene Therapy, KU Leuven, 4Division of Nuclear Medicine, KU Leuven, 5Biomedical NMR Unit/ MoSAIC, KU Leuven

We developed a novel surgical approach for intratracheal administration of bioactive agents into the mouse fetus. The delivery route is more efficient in targeting the fetal mouse lungs than the commonly used intra-amniotic injection. This procedure has to date not been described in a mouse model.

image

Medicine

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Ryan Hodges 1,2, Masayuki Endo 1, Andre La Gerche 3, Elisenda Eixarch 4,5, Philip DeKoninck 1, Vessilina Ferferieva 3, Jan D'hooge 3, Euan M. Wallace 2, Jan Deprest 1
1Division Woman and Child, Department Women, University Hospitals Leuven, 2The Ritchie Centre, Monash Institute of Medical Research, Department of Obstetrics and Gynaecology, Monash University, Victoria, Australia, 3Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, 4Fetal and Perinatal Medicine Research Group, Institut d'Investigacions Biomediques August Pi i Sunyer (IDIBAPS), 5Maternal-Fetal Medicine Department, ICGON, Hospital Clínic, Universitat de Barcelona, Centro de Investigación Biomédica en Red de Enfermedades Raras (CIBERER)

We describe examination of fetal cardiac function with contemporary functional fetal echocardiography and fetoplacental Doppler ultrasound using the VisualSonics VEVO 2100 microultrasound in a surgically induced model of intrauterine fetal growth restriction in a rabbit.

image

Bioengineering

Medical-grade Sterilizable Target for Fluid-immersed Fetoscope Optical Distortion Calibration
Daniil I. Nikitichev *1, Dzhoshkun I. Shakir *1, François Chadebecq 1, Marcel Tella 1, Jan Deprest 1,2, Danail Stoyanov 3, Sébastien Ourselin 1, Tom Vercauteren 1
1Translational Imaging Group, CMIC, University College London, 2Department of Obstetrics and Gynecology, University Hospitals Leuven, 3Surgical Robot Vision Group, CMIC, University College London

This article describes the design and development of a sterilizable custom camera optical distortion calibration target for the peri-operative, fluid-immersed calibration of endoscopes during endoscopic interventions.

image

Medicine

Transvaginal Mesh Insertion in the Ovine Model
Iva Urbankova 1,2, Geertje Callewaert 1,3, Nikhil Sindhwani 1, Alice Turri 1, Lucie Hympanova 1,2, Andrew Feola 1, Jan Deprest 1,3
1Centrum for Surgical Technologies, Department of Development and Regeneration, Clinical Specialties Research Groups, Faculty of Medicine, KU Leuven, 2Institute for the Care of Mother and Child and Third Faculty of Medicine, Charles University, Prague, 3Pelvic Floor Unit, University Hospitals KU Leuven

This protocol describes mesh implantation in the ovine rectovaginal septum using a single vaginal incision technique, with and without the trocar-guided insertion of anchoring arms.

JoVE Logo

Datenschutz

Nutzungsbedingungen

Richtlinien

Forschung

Lehre

ÜBER JoVE

Copyright © 2024 MyJoVE Corporation. Alle Rechte vorbehalten