Inducing a Spinal Cord Contusion in a Mouse Model Using a Spinal Cord Injury Coaxial Platform

-- views • 1:11 min

Transcripción

Begin with an anesthetized mouse on the spinal cord injury coaxial platform, with the exposed 9th thoracic or T9 vertebrae level spinal cord. 

Using the platform’s stabilizer forceps, secure the vertebrae and prevent movement.

Place the tubular sleeve containing the impactor tip with a weight secured with a pull pin over the exposed spinal cord.

Adjust the tip position to accurately target the T9 spinal cord level.

Lower the sleeve until the impactor tip reaches the predetermined height above the spinal cord. 

Release the pull pin to drop the weight onto the impactor tip, striking the spinal cord with controlled impact. 

The impact delivers a blunt force that causes tissue compression, leading to structural damage in axons and blood vessels. 

This results in a contusion or injury from tissue compression. 

Remove the impactor. Tissue discoloration and swelling indicate a successful spinal cord contusion.

article

01:01

Inducing a Spinal Cord Contusion in a Mouse Model Using a Spinal Cord Injury Coaxial Platform

Videos relacionados

13 Views

article

10:00

Un modelo Contusión de la lesión de la médula espinal severa en ratas

Videos relacionados

30.3K Views

article

09:24

Una novela Vertebral Método de Estabilización para Producir contuso Lesiones de la Médula Espinal

Videos relacionados

17.5K Views

article

09:41

Calibrado Pinzas Modelo de Lesión Medular Compresión

Videos relacionados

18.4K Views

JoVE Logo

Privacidad

Condiciones de uso

Políticas

Investigación

Educación

ACERCA DE JoVE

Copyright © 2025 MyJoVE Corporation. Todos los derechos reservados