Laboratory of Clinical Investigation
David A. Reiter has not added Biography.
If you are David A. Reiter and would like to personalize this page please email our Author Liaison for assistance.
In vitro measurements of porcine anterior column units under free swelling.
Journal of biomechanical engineering Dec, 2003 | Pubmed ID: 14986413
Multicomponent T2 relaxation analysis in cartilage.
Magnetic resonance in medicine Apr, 2009 | Pubmed ID: 19189393
Sensitivity and specificity of univariate MRI analysis of experimentally degraded cartilage.
Magnetic resonance in medicine Nov, 2009 | Pubmed ID: 19705467
Classification of degraded cartilage through multiparametric MRI analysis.
Journal of magnetic resonance (San Diego, Calif. : 1997) Nov, 2009 | Pubmed ID: 19762258
Characterization of ex vivo-generated bovine and human cartilage by immunohistochemical, biochemical, and magnetic resonance imaging analyses.
Tissue engineering. Part A Jul, 2010 | Pubmed ID: 20136403
Mapping proteoglycan-bound water in cartilage: Improved specificity of matrix assessment using multiexponential transverse relaxation analysis.
Magnetic resonance in medicine Feb, 2011 | Pubmed ID: 21264931
Effects of frozen storage and sample temperature on water compartmentation and multiexponential transverse relaxation in cartilage.
Magnetic resonance imaging May, 2011 | Pubmed ID: 21277724
Improved specificity of cartilage matrix evaluation using multiexponential transverse relaxation analysis applied to pathomimetically degraded cartilage.
NMR in biomedicine Dec, 2011 | Pubmed ID: 21465593
Anomalous NMR relaxation in cartilage matrix components and native cartilage: fractional-order models.
Journal of magnetic resonance (San Diego, Calif. : 1997) Jun, 2011 | Pubmed ID: 21498095
Characterization of engineered cartilage constructs using multiexponential T₂ relaxation analysis and support vector regression.
Tissue engineering. Part C, Methods Jun, 2012 | Pubmed ID: 22166112
Improved MR-based characterization of engineered cartilage using multiexponential T2 relaxation and multivariate analysis.
NMR in biomedicine Mar, 2012 | Pubmed ID: 22287335
Noninvasive high resolution mechanical strain maps of the spine intervertebral disc using nonrigid registration of magnetic resonance images.
Journal of biomechanics May, 2012 | Pubmed ID: 22503578
Posteromedial cortex glutamate and GABA predict intrinsic functional connectivity of the default mode network.
NeuroImage Jan, 2013 | Pubmed ID: 23000786
Single cell spectroscopy: noninvasive measures of small-scale structure and function.
Methods (San Diego, Calif.) Dec, 2013 | Pubmed ID: 23886910
Stabilization of the inverse Laplace transform of multiexponential decay through introduction of a second dimension.
Journal of magnetic resonance (San Diego, Calif. : 1997) Nov, 2013 | Pubmed ID: 24035004
Prediction of cartilage compressive modulus using multiexponential analysis of T(2) relaxation data and support vector regression.
NMR in biomedicine Apr, 2014 | Pubmed ID: 24519878
Incorporation of Rician noise in the analysis of biexponential transverse relaxation in cartilage using a multiple gradient echo sequence at 3 and 7 Tesla.
Magnetic resonance in medicine Jan, 2015 | Pubmed ID: 24677270
Bayesian analysis of transverse signal decay with application to human brain.
Magnetic resonance in medicine Sep, 2015 | Pubmed ID: 25242062
Sensitivity and specificity of univariate MRI analysis of experimentally degraded cartilage under clinical imaging conditions.
Journal of magnetic resonance imaging : JMRI Jul, 2015 | Pubmed ID: 25327944
Classification of histologically scored human knee osteochondral plugs by quantitative analysis of magnetic resonance images at 3T.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society May, 2015 | Pubmed ID: 25641500
Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.
Magnetic resonance in medicine Jun, 2016 | Pubmed ID: 26140371
Region of interest correction factors improve reliability of diffusion imaging measures within and across scanners and field strengths.
NeuroImage Oct, 2015 | Pubmed ID: 26146196
Anomalous T2 relaxation in normal and degraded cartilage.
Magnetic resonance in medicine Sep, 2016 | Pubmed ID: 26336966
31P Magnetic Resonance Spectroscopy Assessment of Muscle Bioenergetics as a Predictor of Gait Speed in the Baltimore Longitudinal Study of Aging.
The journals of gerontology. Series A, Biological sciences and medical sciences Dec, 2016 | Pubmed ID: 27075894
Insulin Resistance Is Associated With Reduced Mitochondrial Oxidative Capacity Measured by 31P-Magnetic Resonance Spectroscopy in Participants Without Diabetes From the Baltimore Longitudinal Study of Aging.
Diabetes Jan, 2017 | Pubmed ID: 27737951
Vidhya Kumar1,
Henry Chang1,
David A. Reiter2,
David P. Bradley3,
Martha Belury4,
Shana E. McCormack5,
Subha V. Raman1
1Davis Heart and Lung Research Institute, The Ohio State University,
2Laboratory of Clinical Investigation, National Institute on Aging,
3Division of Endocrinology, Diabetes and Metabolism, The Ohio State University,
4Department of Human Sciences, Human Nutrition, The Ohio State University,
5Division of Endocrinology and Diabetes, Department of Pediatrics, University of Pennsylvania
JoVEについて
Copyright © 2023 MyJoVE Corporation. All rights reserved