The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.

Nebulization is the process of introducing samples in the form of aerosols. A nebulizer generates a fine spray of droplets from the liquid sample, allowing efficient atomization. Once atomized, the sample in a flame or plasma forms a steady-state population of atoms, molecules, and ions. The emission from the plasma is then separated into constituent wavelengths using a wavelength isolation device, such as a monochromator, polychromator, or spectrograph. The isolated radiation is converted into electrical signals by transducers or array detectors, which are then processed and analyzed by computer systems.

Inductively coupled plasma (ICP) emission systems utilize a high-temperature plasma called an argon plasma torch instead of a flame. This enables a broader application and rapid multi-element analysis. In the direct-current plasma source (DCP), heating of inert gas is achieved through a DC-arc, establishing the plasma in a high-velocity gas stream. The DCP design commonly uses an inverted V-shaped electrode assembly with the excitation region at the intersection of argon streams, and a nebulizer is employed to inject the sample at this point.

Different instruments are available for multi-element determinations, including sequential spectrometers that scan different emission lines in sequence and simultaneous spectrometers that use polychromators or spectrographs to measure multiple wavelengths simultaneously. The instrumentation of atomic emission spectrometry offers different optical path options, including sequential optical paths with monochromators for sequential wavelength measurement and simultaneous direct reading polychromators with multiple exit slits and phototubes for simultaneous measurement of multiple emission lines.

章から 14:

article

Now Playing

14.10 : Atomic Emission Spectroscopy: Instrumentation

Atomic Spectroscopy

132 閲覧数

article

14.1 : 原子分光法:吸収、発光、蛍光

Atomic Spectroscopy

338 閲覧数

article

14.2 : 原子分光法:温度の影響

Atomic Spectroscopy

132 閲覧数

article

14.3 : 原子吸光分光法:概要

Atomic Spectroscopy

257 閲覧数

article

14.4 : 原子吸光分光法:機器

Atomic Spectroscopy

197 閲覧数

article

14.5 : 原子吸光分光法:放射線と光源

Atomic Spectroscopy

165 閲覧数

article

14.6 : 原子吸光分光法:噴霧法

Atomic Spectroscopy

157 閲覧数

article

14.7 : 原子吸光分光法:干渉

Atomic Spectroscopy

234 閲覧数

article

14.8 : 原子吸光分光法:ラボ

Atomic Spectroscopy

127 閲覧数

article

14.9 : 原子発光分光法:概要

Atomic Spectroscopy

283 閲覧数

article

14.11 : 原子発光分光法:干渉

Atomic Spectroscopy

64 閲覧数

article

14.12 : 誘導結合プラズマ原子発光分光法:原理

Atomic Spectroscopy

275 閲覧数

article

14.13 : 誘導結合プラズマ原子発光分光法:計測機器

Atomic Spectroscopy

90 閲覧数

article

14.14 : 原子発光分光法:ラボ

Atomic Spectroscopy

72 閲覧数

article

14.15 : 原子蛍光分光法

Atomic Spectroscopy

96 閲覧数

See More

JoVE Logo

個人情報保護方針

利用規約

一般データ保護規則

研究

教育

JoVEについて

Copyright © 2023 MyJoVE Corporation. All rights reserved