Western blotting is an analytical technique for protein identification. It has various applications in immunology and medicine, including detecting diseases like bovine spongiform encephalopathy, mad cow disease, and human and feline immunodeficiency virus from biological samples.

The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.

The proteins from the polyacrylamide gel are transferred to specialized membranes like nitrocellulose (NC) or polyvinylidene difluoride (PVDF). Compared to NC, PVDF has higher durability and protein binding capacity and can be re-probed.

The protein transfer is either by electric current application (electroblotting) or capillary action. In electroblotting, the hydrophobic interactions transfer the negatively charged proteins from the gel and trap them on the membrane. In the other method, a filter paper placed on the gel soaks the buffer by capillary action, simultaneously drawing the proteins from the gel and transferring them to the membrane. To ensure the quality of transferred bands, non-specific protein stains like Ponceau S allow for a reversible check.

The next step, immunoblotting, involves treating the membrane with a blocking buffer like 3-5% Bovine serum albumin or non-fat dried milk. These buffers reduce the chance of non-specific binding of the primary antibody to the membrane. The primary antibodies can either be polyclonal or monoclonal and bind to the protein bands on the membrane through their Fab region. Next, the added secondary antibodies bind and attach to the Fc region of the primary antibodies. The secondary antibodies are tagged with enzymes which, upon suitable substrate addition, produce detectable colorimetric or chemiluminescent signals. Further, densitometry techniques can quantify the optical density of these imaged bands, corresponding to the abundance of proteins in the sample.

The expected result for a western blot can be affected by various factors like erroneous sample loading, inaccurate transfer with trapped air bubbles, and the use of non-specific antibodies. Also, inappropriate primary and secondary antibody concentrations and contaminated buffers can affect the quality of bands and their visualization.

Tags
Western BlottingProtein IdentificationImmunologySDS PAGEProtein TransferImmunoblottingNitrocellulosePolyvinylidene DifluorideElectroblottingCapillary ActionBlocking BufferPrimary AntibodiesSecondary AntibodiesColorimetric SignalsChemiluminescent SignalsDensitometry Techniques

장에서 32:

article

Now Playing

32.13 : Western Blotting

Analyzing Cells and Proteins

14.0K Views

article

32.1 : 세포 분리 및 격리의 개요

Analyzing Cells and Proteins

5.3K Views

article

32.2 : 세포 배양

Analyzing Cells and Proteins

15.8K Views

article

32.3 : 세포주

Analyzing Cells and Proteins

6.8K Views

article

32.4 : 하이브리도마 기술

Analyzing Cells and Proteins

13.2K Views

article

32.5 : 조직 균질화(Tissue Homogenization) 및 세포 용해(Cell Lysis)

Analyzing Cells and Proteins

7.0K Views

article

32.6 : Subcellular 분획

Analyzing Cells and Proteins

6.4K Views

article

32.7 : 유세포 분석

Analyzing Cells and Proteins

11.4K Views

article

32.8 : 컬럼 크로마토그래피의 원리

Analyzing Cells and Proteins

6.4K Views

article

32.9 : 컬럼 크로마토그래피의 종류

Analyzing Cells and Proteins

10.6K Views

article

32.10 : 면역침전물

Analyzing Cells and Proteins

5.1K Views

article

32.11 : 태깅 및 융합 단백질

Analyzing Cells and Proteins

6.5K Views

article

32.12 : SDS 페이지

Analyzing Cells and Proteins

26.0K Views

article

32.14 : 2차원 젤 전기영동

Analyzing Cells and Proteins

5.5K Views

article

32.15 : 효소 결합 면역흡착 분석

Analyzing Cells and Proteins

11.8K Views

See More

JoVE Logo

개인 정보 보호

이용 약관

정책

연구

교육

JoVE 소개

Copyright © 2025 MyJoVE Corporation. 판권 소유