JoVE Logo

로그인

JoVE 비디오를 활용하시려면 도서관을 통한 기관 구독이 필요합니다. 전체 비디오를 보시려면 로그인하거나 무료 트라이얼을 시작하세요.

기사 소개

  • Overview
  • 프로토콜
  • 결과
  • 공개
  • 자료
  • 참고문헌

Overview

This video describes an intraductal injection technique where we deliver injection mix into the ducts of mouse mammary glands.

프로토콜

1. Intraductal injection

  1. Use aseptic techniques throughout the surgical procedure.
  2. Make an incision site on the skin at a length of ~1 cm between the two fourth inguinal MGs (Figure 1). Carefully separate the skin flap (with the MG) from the parietal peritoneum so as to visualize the mammary ductal tree.
  3. Carefully hold the nipple with Watchmaker’s forceps and remove the exterior nipple without cutting any nearby skin, using a micro-dissection scissor.
  4. Load ~3–5 µL of Ad-Cre injection mixture into a 25 µL Hamilton syringe with a 33 G metal hub needle affixed. Estimate the volume of the injection mixture in the syringe based on the blue dye included in the mixture.
    NOTE: Use a smaller volume (e.g., 3 µL) when injecting into MGs of 3–4 weeks old females and a larger volume (e.g., 10 µL) when injecting into MGs of lactating females.
  5. Gently hold the edge of the skin flap with a fine curved tweezer and inject the Ad-Cre injection mixture slowly into the nipple, meanwhile monitoring the spreading of blue dye into the mammary ductal tree. Maintain the injection rate as low as possible to avoid damage to the ductal lumen.
    NOTE: Injected fluid (as illustrated by the included bromophenol blue dye) spreading throughout the entire ductal tree without leaking into the stromal compartment indicates a successful intraductal injection.
  6. Gently withdraw the needle from the nipple to avoid any leakage of the injected fluid.
  7. Examine the distal side (i.e., away from the nipple) of the MG or the surrounding area of the injected nipple. Note that swelling blue dye (i.e., dye diffusing into the nearby stroma) indicates a mammary fat pad injection rather than a successful intraductal injection.
  8. Close the surgical wounds (from 1.2) in the skin with wound clips.

2. Postoperative care

  1. Remove the mouse from the anesthesia and place it on a heating pad inside a clean cage for recovery.
  2. Administer meloxicam subcutaneously at 5 mg/kg again, 24 h after the surgery.
  3. Monitor the general conditions of the animal and look for signs of infection at the incision site for 5 days.
  4. Wound clips are removed ~7-10 days after surgery.

결과

figure-results-25
Figure 1: Schematic diagram of the intraductal injection of Ad-Cre virus into an MG. (A) Incision site in the midline between the two fourth MGs. (B) Intraductal injection of Ad-Cre with a blue dye (for better visualization) into one of the fourth MGs. (C) Closing of the incision in the skin by wound clips

공개

No conflicts of interest declared.

자료

NameCompanyCatalog NumberComments
33-gauge needleHamilton7803-05point style 3 blunt
7mm Reflex ClipBraintree ScientificRF7 CS
Adenovirus, Ad-K5-CreUniversity of Iowa Viral Vector CoreAd5-bk5-Cre (VVC-Berns-1547)
Adenovirus, Ad-K8-CreUniversity of Iowa Viral Vector CoreAd5mK8-nlsCre
Bromophenol BlueSigma-AldrichB0126-25G
Hamilton syringeHamilton7636-010.025 mL
Micro-dissecting scissorsPentair9MWatchmaker's Forceps
Micro-dissecting tweezersDumontM5

참고문헌

This article has been published

Video Coming Soon

JoVE Logo

개인 정보 보호

이용 약관

정책

연구

교육

JoVE 소개

Copyright © 2025 MyJoVE Corporation. 판권 소유