Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.

To test the completeness of the deposition, the fresh electrode surface is exposed to the solution while continuing the electrolysis and checking for new deposits. The absence of new deposits signifies the completion of the reaction. Other tests include checking for color disappearance or conducting a qualitative test for the analyte in the solution.

Underpotential deposition, or monolayer formation on the electrode surface, occurs at a potential below the Nernst equilibrium potential. Conversely, overpotential (a potential above the Nernst potential) is required for bulk metal film deposition. Overpotential factors can cause unwanted reactions and affect the accuracy of the analysis.

Depolarizers can be added to prevent undesired side reactions by scavenging excess electrons into non-interfering reactions and controlling the working electrode's potential.

Из главы 10:

article

Now Playing

10.12 : Electrogravimetric Analysis: Overview

Electrochemical Analyses and Redox Titration

131 Просмотры

article

10.1 : Electrochemistry: Overview

Electrochemical Analyses and Redox Titration

424 Просмотры

article

10.2 : Electrodes: Overview

Electrochemical Analyses and Redox Titration

249 Просмотры

article

10.3 : Interfacial Electrochemical Methods: Overview

Electrochemical Analyses and Redox Titration

167 Просмотры

article

10.4 : Potentiometry: Overview

Electrochemical Analyses and Redox Titration

335 Просмотры

article

10.5 : Potentiometry: Types of Electrodes

Electrochemical Analyses and Redox Titration

324 Просмотры

article

10.6 : Potentiometry: Membrane Electrodes

Electrochemical Analyses and Redox Titration

259 Просмотры

article

10.7 : Redox Titration: Overview

Electrochemical Analyses and Redox Titration

205 Просмотры

article

10.8 : Redox Titration: Iodimetry and Iodometry

Electrochemical Analyses and Redox Titration

474 Просмотры

article

10.9 : Redox Titration: Other Oxidizing and Reducing Agents

Electrochemical Analyses and Redox Titration

123 Просмотры

article

10.10 : Potentiometric Titration: Overview

Electrochemical Analyses and Redox Titration

346 Просмотры

article

10.11 : End Point Prediction: Gran Plot

Electrochemical Analyses and Redox Titration

126 Просмотры

article

10.13 : Coulometry: Overview

Electrochemical Analyses and Redox Titration

121 Просмотры

article

10.14 : Controlled-Potential Coulometry: Electrolytic Methods

Electrochemical Analyses and Redox Titration

87 Просмотры

article

10.15 : Controlled-Current Coulometry: Overview

Electrochemical Analyses and Redox Titration

110 Просмотры

See More

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены