Standard solutions refer to solutions with a precisely known concentration or composition. A primary standard is a highly pure, high molar mass, stable substance that is entirely soluble in water, the most commonly used solvent in analytical chemistry. The primary standard solution can be used to standardize secondary standards, which are substances with known concentrations but are less pure and stable. Standard solutions are essential for achieving accurate and reliable results in analytical procedures, so understanding them is crucial for anyone working in a laboratory setting.

The preparation of a standard solution using a primary standard involves several steps:

  1. Weigh the Primary Standard: Use a funnel to carefully transfer the weighed primary standard into a clean and dry volumetric flask. It is crucial to use a weighing balance capable of providing precise measurements.
  2. Transfer Standard to Volumetric Flask: Use a funnel to carefully transfer the weighted primary standard into a clean and dry volumetric flask. Ensure all the solid is transferred from the weighing boat to the flask. After the transfer, reweigh the empty weighing boat to confirm no residue remains.
  3. Wash the Funnel: Use small quantities of distilled water to wash down any solid material from the funnel into the volumetric flask. This ensures that all of the primary standard is dissolved in the solution.
  4. Dissolve the Solid: Swirl the volumetric flask until the solid is completely dissolved. It may be necessary to add water gradually until the solid is completely dissolved.
  5. Approach the Calibration Line: Add more distilled water to bring the solution level close to the calibration mark on the neck of the volumetric flask. Ensure the solid is completely dissolved before adding more solvent to avoid exceeding the calibration line.
  6. Adjust the Meniscus: Use a pipette to add water drop by drop until the bottom of the meniscus (the curve at the surface of the liquid) aligns precisely with the calibration mark. This step ensures that the solution has the correct volume and concentration.
  7. Mix the Solution: Securely close the volumetric flask and invert it several times to ensure complete solution mixing.
  8. Label: Label the volumetric flask with the chemical composition, solution concentration, and preparation date. This information helps identify and use the solution correctly.

Из главы 9:

article

Now Playing

9.9 : Standard Solutions

Method Development and Sampling Techniques

111 Просмотры

article

9.1 : Разработка аналитических методов

Method Development and Sampling Techniques

217 Просмотры

article

9.2 : Контроль качества

Method Development and Sampling Techniques

89 Просмотры

article

9.3 : Гарантия качества

Method Development and Sampling Techniques

67 Просмотры

article

9.4 : Проверка данных

Method Development and Sampling Techniques

86 Просмотры

article

9.5 : Качественный анализ

Method Development and Sampling Techniques

108 Просмотры

article

9.6 : Количественный анализ

Method Development and Sampling Techniques

152 Просмотры

article

9.7 : Калибровка прибора

Method Development and Sampling Techniques

102 Просмотры

article

9.8 : Калибровка стеклянной посуды

Method Development and Sampling Techniques

97 Просмотры

article

9.10 : Пустые решения

Method Development and Sampling Techniques

108 Просмотры

article

9.11 : Методы отбора проб: обзор

Method Development and Sampling Techniques

140 Просмотры

article

9.12 : Методы отбора проб: типы проб

Method Development and Sampling Techniques

127 Просмотры

article

9.13 : Планы отбора проб

Method Development and Sampling Techniques

121 Просмотры

article

9.14 : Подготовка образцов к анализу: обзор

Method Development and Sampling Techniques

98 Просмотры

article

9.15 : Подготовка образцов к анализу: передовые методики

Method Development and Sampling Techniques

120 Просмотры

See More

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены