Войдите в систему

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the wye-connected load are directly equal to the line currents from the delta source, due to the load's wye configuration simplifying the flow from the delta source. The relationship between the line and phase currents in a wye configuration shows that the phase current in the wye-connected load equals the line current of the delta-connected source.

Another way to obtain the line currents is to replace the delta-connected source with its equivalent wye-connected source. The line-to-line voltages of a wye-connected source lead their corresponding phase voltages by 30 degrees. This means that each phase voltage of the equivalent wye-connected source is obtained by dividing the corresponding line voltage of the delta-connected source by the square root of three and shifting its phase by -30 degrees. As a result, the equivalent wye-connected source has phase voltages shifted by 120 degrees accordingly.

By converting a delta configuration to a star configuration, the system can achieve better voltage regulation and allow for the use of a neutral wire. This neutral wire enables the system's grounding, enhancing safety and stability.

The balanced delta-to-delta configuration is used to transmit electricity over long distances, where high voltage levels need to be stepped down to usable levels for industrial, commercial, and residential use.

Теги

Delta wye CircuitDelta connected SourceWye ConfigurationPhase VoltageLine VoltageLine CurrentsPhase CurrentsPositive SequenceVoltage RegulationNeutral WireElectrical GroundingBalanced SystemPhase Difference

Из главы 8:

article

Now Playing

8.7 : The Delta-to-Y Circuit

Three-Phase Circuits

269 Просмотры

article

8.1 : Three-Phase Circuits

Three-Phase Circuits

342 Просмотры

article

8.2 : Generation of Three-Phase Voltage

Three-Phase Circuits

297 Просмотры

article

8.3 : Three-Phase Voltages

Three-Phase Circuits

195 Просмотры

article

8.4 : The Y-to-Y Circuit

Three-Phase Circuits

348 Просмотры

article

8.5 : The Y-to-Delta Circuit

Three-Phase Circuits

358 Просмотры

article

8.6 : The Delta-to-Delta Circuit

Three-Phase Circuits

446 Просмотры

article

8.8 : Power in a Three-Phase Circuit

Three-Phase Circuits

247 Просмотры

article

8.9 : Power Distribution in Three-phase and Single Phase Circuits

Three-Phase Circuits

245 Просмотры

article

8.10 : Line Loss

Three-Phase Circuits

214 Просмотры

article

8.11 : Reducing Line Loss

Three-Phase Circuits

127 Просмотры

JoVE Logo

Исследования

Образование

О JoVE

Авторские права © 2025 MyJoVE Corporation. Все права защищены