A subscription to JoVE is required to view this content. Sign in or start your free trial.

In This Article

  • Summary
  • Abstract
  • Introduction
  • Protocol
  • Results
  • Discussion
  • Disclosures
  • Acknowledgements
  • Materials
  • References
  • Reprints and Permissions

Summary

This article focuses on robotic vagus-sparing total gastrectomy. The techniques and pitfalls of vagus preservation, sutured esophagojejunostomy, jejunal pouch formation, and Roux-en-Y reconstruction with a staple-stapled jejunojejunostomy are discussed.

Abstract

Hereditary diffuse gastric cancer (HDGC) caused by the CDH1 gene mutation is an inherited cancer syndrome that increases the risk of diffuse gastric cancer and is nearly impossible to detect by screening gastroscopy. The recommended preventative treatment is a total gastrectomy. Robotic surgery facilitates the use of minimally invasive surgical (MIS) techniques for anastomoses and posterior vagus preservation to potentially reduce adverse functional outcomes. An asymptomatic 24 year old male with the CDH1 gene mutation proven by genetic testing and a family history of a brother having a total gastrectomy for HDGC was treated with this technique. This video case report demonstrates the techniques and pitfalls of robotic surgery in terms of the patient positioning and port placement, posterior vagus-preserving dissection, sutured esophagojejunostomy, jejunal pouch formation, and Roux-en-Y reconstruction with a staple-stapled jejunojejunostomy. While these techniques are demonstrated in the case of prophylactic gastrectomy, many of them can be applied to other benign and bariatric foregut and general surgery types.Robotic surgery can facilitate the foregut MIS technique, as described in this case of a vagus-sparing total gastrectomy.

Introduction

Hereditary diffuse gastric cancer (HDGC) is characterized by a genetic mutation in the E-cadherin (CDH1) tumor suppressor gene, which has an autosomal dominant pattern of inheritance1. This inherited cancer syndrome increases the risk of diffuse gastric cancer and lobular breast cancer (LBC). Current guidelines recommend testing for CDH1 mutations in patients with familial clusters of HDGC and LBC, particularly in those with early onset (before 40 years of age)2. According to the largest reported series of CDH1 mutation carriers, the cumulative lifetime incidence of gastric cancer is 70% (95% CI, 59%-80%) for males and 56% (95% CI, 44%-69%) for females with this mutation3. However, recent studies have estimated gastric cancer penetrance with this mutation to be in the range of 37%-42% for males and 25%-33% for females1.

Endoscopic surveillance with biopsies is the recommended surveillance type for those choosing to delay prophylactic gastrectomy; however, it is nearly impossible to detect early gastric cancer in this cohort using screening gastroscopy2. Extensive white-light endoscopic examination is followed by a minimum of 30 non-targeted gastric biopsies from five separate areas of the stomach. However, this surveillance method has a high false-negative rate and only detects 20%-63% of occult signet ring cell foci4,5.

Prophylactic total gastrectomy (PTG) is the recommended preventative treatment for any pathogenic or likely pathogenic CDH1 variant carrier starting at the age of 20 years, but it is not recommended beyond 70 years of age1,2. Perigastric lymph node metastasis is an uncommon finding in asymptomatic patients, who typically have T1a or in situ signet ring cells. Perioperative morbidity is generally low, and patient satisfaction is high6. Though the overall quality of life following surgery is high, a truncal vagotomy is generally performed in a total gastrectomy7,8. The resection of the vagus nerve above the level of the celiac and hepatic branches leads to parasympathetic denervation of the hepatobiliary tree and the small and large intestine. Post-vagotomy diarrhea and dumping syndrome are well-recognized long-term complications following PTG8.

Robotic surgery provides the surgeon with a 3-dimensional, 10x magnified view of the surgical field and offers a high degree of freedom with articulating surgical instruments9. The aim of preforming this technique is to potentially reduce adverse functional outcomes through posterior vagus preservation, which is facilitated by minimally invasive surgical (MIS) techniques.

Protocol

The patient provided informed consent for the publication of de-identified information, images, and video documentation. Associate Professor Dr. Michael Talbot (co-author) is an upper gastrointestinal surgeon accredited to perform gastrectomy at his institution. Due to the negligible risk of this case report and protocol, it was exempt from an ethics review as per the local institutional review board guidelines. Ethics application for case reports are exempted as per the local institutional review board guidelines.

1. Patient positioning

  1. Place the patient in the reverse Trendelenburg position after general anesthesia has been given.
  2. Secure the patient in position with a foot plate, a body strap placed above the knees, and ankle straps. Abduct (<90°) the arms, and crepe bandage them to the arm boards. Place a Nathanson liver retractor bracket on the operating table, cranial to the left arm board.

2. Port placement (Figure 1)

  1. Make a 12 mm skin incision via the surgeon's preferred approach in the right midclavicular position at or below the level of the umbilicus. Perform an optical entry with an 8 mm, 0° laparoscope scope and with a 12 mm port through this incision. Note, the camera port should be 10-20 cm from the target anatomy.
  2. Exchange the port for a 12 mm robotic (stapling) port with a 12-8 mm reducer, and swap the laparoscope with an 8 mm, 30° laparoscope. Establish 15 mmHg CO2 pneumoperitoneum with 45 mmHg flow.
  3. Make three additional 8 mm skin incisions in the transumbilical plane, and place three 8 mm robotic ports. Place one of the robotic ports at the umbilicus and the other two robotic ports lateral to it on the left side. Ensure there is a >8 cm distance between the ports and a 10-20 cm distance between the ports and the target anatomy.
  4. Place another 12 mm assistant port (port A) in the upper-right quadrant. Insert a Nathanson retractor into the epigastrium through a 5 mm incision, and retract the left lobe of the liver.
  5. Place the robotic patient cart over the patient from the patient's right side, taking care to avoid collision with the liver retractor. Dock the camera arm first using the laser-guided port placement. Perform an incisura targeting the stomach with an 8 mm, 30° robotic scope using port 3.
  6. Dock and burp the remaining robotics ports to the instrument arms, and then insert a force bipolar 8 mm instrument (port 1), a vessel sealer extend (port 2), and a tip-up fenestrated grasper (pot 4). Set the monopolar and bipolar auto-cut and forced coagulation at effect 3, and check the system setup.

figure-protocol-2944
Figure 1: Robotic port placement. The Nathanson retractor handle is seen in the epigastrium. There is a 12 mm assistant port in the upper-right quadrant. The remaining ports from the left to the right of the image are the 12 mm robotic port with reducer, the 8 mm camera port, and two additional 8 mm robotic ports. Please click here to view a larger version of this figure.

3. Vagus-preserving dissection

  1. Mobilize the greater curve of the stomach through the gastrocolic ligament from the antrum to the cardia and divide into five to seven short gastric vessels lateral to the arcade vessel sealer extend to include the N1 nodes. Then, mobilize the left side of the esophageal hiatus.
  2. Enter the phrenoesophageal ligament and mobilize the left side of the distal esophagus. Perform distal dissection with the vessel sealer and continue down to the mobilization of the first part of the duodenum. Follow the supraduodenal window through the pars flaccida to complete the right-sided esophageal mobilization, with the plane of dissection abutting the esophagus.
  3. Transect the first part of the duodenum with the robotic stapler using a 60 mm x 4.3 mm green reload with a buttress reinforcement. Divide the left gastric vessels close to the wall of the stomach using the vessel sealer. This is to ensure that the posterior vagus is left undivided in the mesentery around the left gastric pedicle.
  4. Retract the esophagus and stomach in the superolateral direction and identify the posterior vagus nerve. Sweep the nerve posteriorly and preserve it.

4. Suture of the esophagojejunostomy with a jejunal pouch

  1. Phrenoesophageal ligament reconstruction
    1. Perform the phrenoesophageal ligament reconstruction in a continuous anticlockwise direction from the 5 o'clock to 9 o'clock position using a 2-0 nonabsorbable barbed suture on a 26 mm 1/2 circle taper point needle. Transect the intraabdominal esophagus with the robotic stapler using a 60 mm x 4.3 mm green reload. Move the detached stomach to the upper-right quadrant.
  2. Esophagojejunal anastomosis
    1. Raise the greater omentum cranially to identify the duodenojejunal flexure and bring a jejunal loop of 50 cm (creating a 40-60 cm biliopancreatic limb after the jejunal pouch formation) to the esophagus.
    2. Suture a 23 cm long 3-0 absorbable barbed suture on a 26 mm 1/2 circle taper point needle as a 3 o'clock lateral esophagojejunal pexy. Retract the uncut suture laterally. Create an esophagostomy anterior to the staple line using a monopolar diathermy hook with an 18Fr nasogastric tube guide. Create a jejunostomy of an equal or slightly smaller size as done for esophagostomy.
    3. Suture the posterior wall of the esophagojejunostomy with the barbed suture in a continuous, clockwise fashion from the 3 o'clock to 9 o'clock position, incorporating the staple line. Suture the anterior portion using another of the same suture to complete the full-thickness single-layered suture for the esophagojejunal anastomosis. Place a few medial sutures beyond the anastomosis as a medial pexy.
  3. Jejunal pouch
    1. Transect the proximal jejunal loop at 10 cm from the anastomosis with a robotic stapler using a 60 mm x 2.5 mm white reload. Create antimesenteric enterostomies 10 cm proximal and distal to the esophagojejunal anastomosis.
    2. Perform two firings of the robotic stapler using 60 mm x 2.5 mm white reloads to create the jejunal pouch. Ensure the second firing does not go all the way to meet the esophagojejunal anastomosis in order to preserve the blood supply to the anastomoses. Close the jejunal enterotomy in a continuous fashion with a 3-0 absorbable barbed suture.

5. Stapled jejunojejunostomy

  1. Measure a 70 cm alimentary limb and place a 2-0 silk interrupted suture at this point and the distal biliopancreatic limb for both marking and retraction.
  2. Form the jejunojejunostomy using a staple-only technique, as described in the triple-stapling technique for laparoscopic gastric bypass10,11. Use a 60 mm x 2.5 mm white reload to form the anastomosis and close the enterotomy.
  3. Close both the jejunal and retro-Roux mesenteric defects using 2-0 nonabsorbable barbed sutures to reduce the risk of complications due to internal herniation.

6. Specimen extraction and closure

  1. Remove the instruments, Nathanson retractor, and ports under robotic vision. Undock the robotic patient cart from the patient.
  2. Create a 5 cm mini-laparotomy through the extension of the umbilical port. Deliver the specimen through a small O-ring wound protector retractor. Close the laparotomy in the usual fashion using muscle sparing sutures with continuous fascial closure and with a 1:4 suture to wound length ratio.

Results

The total operative time was 2 h 50 min, and the patient had an unremarkable postoperative course. The patient was placed on a free fluids diet on day 1 post surgery and discharged from the hospital on day 4. At the 1 month and 3-month follow-up, the patient was well and reported no diarrhea or dumping symptoms.

The specimen was sent for pathological examination and demonstrated five areas of superficial invasion of the lamina propria by signet ring cell adenocarcinoma. These areas were micros...

Discussion

An asymptomatic 24 year old male with the CDH1 gene mutation proven by genetic testing and a family history of a brother having a total gastrectomy for HDGC was selected. The preoperative endoscopy was unremarkable. The case is used as a platform to discuss the techniques and the pitfalls of key aspects of it. This includes the patient positioning and port placement, posterior vagus-preserving dissection, sutured esophagojejunostomy, jejunal pouch formation, and Roux-en-Y reconstruction with a triple stapled jejunojejuno...

Disclosures

The authors have nothing to disclose.

Acknowledgements

The authors acknowledge the Upper Gastrointestinal and Metabolic Research Foundation for funding the journal publication fees. The authors also acknowledge the patient in this case for their consent to the publication of their de-identified information and images.

Materials

NameCompanyCatalog NumberComments
Laparoscopic instruments
5 mm optical entry portApplied MedicalCFF03Kii Fios First entry access system. 
Laparoscopic 5mm 0° cameraOlympusENDOEYE HD II5 mm, 0°
Laparoscopic needle holderKARL STORZLaparoscopic needle holder
Nasogastric tubeCardinal Health8888264960E16Fr
Nathanson liver retractorCOOK MedicalNLRS-1001/ NLRS-1002Large/ Extra-large
Robotic instruments
12 mm portIntuitive Surgical470375
8 mm portIntuitive Surgical470380
8 mm reducerIntuitive Surgical470381
Da Vinci Xi/X Endoscope with Camera, 8 mm, 0°Intuitive Surgical470026
Da Vinci Xi/X Endoscope with Camera, 8 mm, 30°Intuitive Surgical470027
da Vinci Xi Surgical System (DVSS)Intuitive Surgical1N/A
Force Bipolar 8 mmIntuitive Surgical470405
Mega SutureCut Needle DriverIntuitive Surgical470309
Monopolar hook diathermyIntuitive Surgical470183
SureForm 60mm staplerIntuitive Surgical480460
Tip-up fenetrated grasper 8 mmIntuitive Surgical470347
Vessel Sealer Extend 8 mmIntuitive Surgical480422
Stapler reloads
Seamguard buttress 60 mmGORE1BSGXI60GB/12BSGXI60GB
SureForm 60 mm green reloadIntuitive Surgical 48360G
SureForm 60 mm white reloadIntuitive Surgical48360W
Sutures
2-0 nonabsorbable barbed suture Medtronic VLOCN064423 cm V-Loc on a 26 mm ½ circle taper point needle
3-0 absorbable barbed suture Medtronic/ Ethicon (J&J)VLOCM064423 cm V-Loc on a 26 mm ½ circle taper point needle (preferred), STRATAFIX (alternate). Catalogue number 
2-0 monocryl sutureEthicon (J&J) JJW3463Cut to 15 cm, taper point needle
2-0 silk sutureEthicon (J&J) JJ423HCut to 15 cm, taper point needle
1 PDS sutureEthicon (J&J) JJ75414Fascial closure
3-0 monocryl sutureEthicon (J&J) JJY227HSkin closure
Topical Skin AdhesiveEthicon (J&J) JJ79025Skin closure/ wound dressing
Specimen extraction 
Alexis O-ring wound retractorApplied MedicalC8402Medium. For specimen extraction
Handheld diathermyCovidien/ Valleylab VLE2515For specimen extraction

References

  1. Gamble, L. A., Heller, T., Davis, J. L. Hereditary diffuse gastric cancer syndrome and the role of CDH1: A review. JAMA Surgery. 156 (4), 387-392 (2021).
  2. Shenoy, S. CDH1 (E-cadherin) mutation and gastric cancer: Genetics, molecular mechanisms and guidelines for management. Cancer Management and Research. 11, 10477-10486 (2019).
  3. Hansford, S., et al. Hereditary diffuse gastric cancer syndrome: CDH1 mutations and beyond. JAMA Oncology. 1 (1), 23-32 (2015).
  4. Friedman, M., et al. Surveillance endoscopy in the management of hereditary diffuse gastric cancer syndrome. Clincal Gastroenterology and Hepatology. 19 (1), 189-191 (2021).
  5. van der Post, R. S., et al. Hereditary diffuse gastric cancer: updated clinical guidelines with an emphasis on germline CDH1 mutation carriers. Journal of Medical Genetics. 52 (6), 361-374 (2015).
  6. Kaurah, P., et al. Hereditary diffuse gastric cancer: Cancer risk and the personal cost of preventive surgery. Familal Cancer. 18 (4), 429-438 (2019).
  7. Hejazi, R. A., Patil, H., McCallum, R. W. Dumping syndrome: Establishing criteria for diagnosis and identifying new etiolo gies. Digestive Diseases and Sciences. 55 (1), 117-123 (2010).
  8. Johnston, D. Operative mortality and postoperative morbidity of highly selective vagotomy. British Medical Journal. 4 (5996), 545-547 (1975).
  9. Nakauchi, M., et al. Robotic surgery for the upper gastrointestinal tract: Current status and future perspectives. Asian Journal of Endoscopic Surgery. 10 (4), 354-363 (2017).
  10. Frantzides, C. T., et al. Laparoscopic Roux-en-Y gastric bypass utilizing the triple stapling technique. Journal of the Society of Laparoendoscopic Surgeons. 10 (2), 176-179 (2006).
  11. Madan, A. K., Frantzides, C. T. Triple-stapling technique for jejunojejunostomy in laparoscopic gastric bypass. Archives of Surgery. 138 (9), 1029-1032 (2003).
  12. Forrester, J. D., et al. Surgery for hereditary diffuse gastric cancer: Long-term outcomes. Cancers. 14 (3), 728 (2022).

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Explore More Articles

Robotic SurgeryTotal GastrectomyCDH1 Gene MutationHereditary Diffuse Gastric CancerHDGCMinimally Invasive Surgical TechniquesVagus PreservationAnastomosesGenetic TestingEsophagojejunostomyJejunal Pouch FormationRoux en Y ReconstructionStaple stapled JejunojejunostomyForegut Surgery

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2025 MyJoVE Corporation. All rights reserved