The principle of conservation of mass is fundamental in fluid dynamics and is crucial for analyzing flow within fixed control volumes, such as pipes or ducts. This principle states that the total mass within a control volume remains constant unless altered by the inflow or outflow of mass through the control surfaces. This results in a vital relationship for steady, incompressible flow where the mass entering a system equals the mass leaving it.

In the case of a sewer pipe, which can be modeled as a fixed, nondeforming control volume, mass conservation dictates that the inlet's mass flow rate must equal the outlet's mass flow rate. The control surfaces in this scenario are at the inlet and outlet of the pipe, enclosing the flow region. Given that the flow is incompressible, the density of the fluid remains constant. This means that the relationship between velocity and cross-sectional area becomes critical.

Mass Flow Rate and Cross-Sectional Area

The mass flow rate () is expressed in terms of fluid density (Ρ) and flow rate (Q). Here, the flow rate is determined by multiplying the velocity (V) by the cross-sectional area (A).

Equation 1

For steady flow, where the density remains constant, this equation simplifies to indicate that any change in velocity must correspond to a change in the pipe's cross-sectional area. When the pipe's cross-sectional area decreases, as might happen at the outlet of a sewer pipe, the velocity of the fluid must increase to conserve mass flow rate. The continuity equation describes this phenomenon:

Equation 2

Where V1 and A1 denotes the velocity and cross-sectional area at the inlet and V2 and A2 at the outlet. This relationship predicts flow behavior and design systems that maintain appropriate flow rates while adhering to the principle of mass conservation.

Aus Kapitel 18:

article

Now Playing

18.2 : Conservation of Mass in Fixed, Nondeforming Control Volume

Finite Control Volume Analysis

14 Ansichten

article

18.1 : Erhaltung der Masse im endlichen Kotrolvolumen

Finite Control Volume Analysis

24 Ansichten

article

18.3 : Erhaltung der Masse in bewegtem, nicht verformendem Kontrollvolumen

Finite Control Volume Analysis

14 Ansichten

article

18.4 : Linearer Impuls in der Lautstärke

Finite Control Volume Analysis

11 Ansichten

article

18.5 : Anwendung der linearen Impulsgleichung

Finite Control Volume Analysis

11 Ansichten

article

18.6 : Moment-of-Momentum-Gleichung

Finite Control Volume Analysis

13 Ansichten

article

18.7 : Energieeinsparung im Regelvolumen

Finite Control Volume Analysis

12 Ansichten

article

18.8 : Anwendung der Energiegleichung

Finite Control Volume Analysis

26 Ansichten

article

18.9 : Bemessungsbeispiel: Kräfte im Schleusentor

Finite Control Volume Analysis

45 Ansichten

JoVE Logo

Datenschutz

Nutzungsbedingungen

Richtlinien

Forschung

Lehre

ÜBER JoVE

Copyright © 2025 MyJoVE Corporation. Alle Rechte vorbehalten