Sign In

University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg

4 ARTICLES PUBLISHED IN JoVE

image

Medicine

Blood Circuit Reconstruction in an Abdominal Mouse Heart Transplantation Model
Decheng Yin *1,2, Jian Fu *1,3, Ida Allabauer 1, Oliver Witzke 4, Song Rong 5, André Hoerning 1
1Department of Pediatric and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, 2Department of Pediatric Surgery, Chengdu Women's and Children's Central Hospital, 3The Key Laboratory of Hainan Trauma and Disaster Rescue, The first affiliated Hospital of Hainan Medical University, 4Department of Infectious Diseases, West German Centre of Infectious Diseases, Universitätsmedizin Essen, University Duisburg-Essen, 5Department of Nephrology, Hannover Medical School

A novel technique for blood circuit reconstruction in a heterotopic abdominal mouse heart transplantation model is demonstrated.

image

Immunology and Infection

A Modified Surgical Technique for Kidney Transplantation in Mice
Decheng Yin *1,2, Jian Fu *1,3, Rongjun Chen 4, Nelli Shushakova 5, Ida Allabauer 1, Xin-Yi Wei 1, Mario Schiffer 6, Diana Dudziak 7, Song Rong *5, André Hoerning *1
1Department of Pediatric and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, 2Department of Pediatric Surgery, Chengdu Women’s and Children's Central Hospital, 3The Key Laboratory of Hainan Trauma and Disaster Rescue, The first affiliated Hospital of Hainan Medical University, 4Department of Department of Pediatric Kidney, Liver, and Metabolic Diseases, Hannover Medical School, 5Department of Nephrology, Hannover Medical School, 6Department of Nephrology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, 7Department of Dermatology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg

This protocol presents a new surgical technique of mouse kidney transplantation focusing on a modified arterial anastomosis strategy. A vascular suture technique including a simple and safer ureter-bladder anastomosis method is also presented. These modifications shorten the operation time and improve the success rate of the mouse kidney transplantation procedure.

image

Engineering

Modeling and Experimental Analysis of the Single-Shaft Coaxial Motor-Pump Assembly in Electrohydrostatic Actuators
Jiangao Zhao 1,2, Deming Zhu 2,3, Yuxuan Ma 2,3, Yongling Fu 2,3, Jian Fu 2,3
1Research Institute for Frontier Science, Beihang University, 2School of Mechanical Engineering and Automation, Beihang University, 3Laboratory of Aerospace Servo Actuation and Transmission, Beihang University

We built a simulation model to evaluate pump flow characteristics and performance of the single-shaft coaxial motor-pump assembly in electrohydrostatic actuators and investigate the overall efficiency in a wide set of working conditions of the motor-pump assembly experimentally.

image

Education

A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Xu Han 1, Peng Zhang 2, Tatiana Minav 3, Yongling Fu 1, Jian Fu 1
1School of Mechanical Engineering and Automation, Beihang University, 2Beijing Institute of Precision Mechatronics and Controls, 3Innovative Hydraulics and Automation, Tampere University

A simulation model specifically supporting the preliminary design of an electro-variable displacement pump (EVDP) is developed and partially verified by experiments. The control performance, life, reliability, etc., can all be evaluated using the proposed model, which covers the main performance requirements under the EVDP preliminary design task.

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved