Many fundamental cell functions such as muscle contraction and nerve transmission rely on the electrical signals produced by the movement of positively and negatively charged ions across the cell membrane. One competent method to record current flowing across the whole cell or single ion channel is the patch-clamp technique.

In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell membrane is electrically isolated, ensuring that the ions moving across the channels flow only into the micropipette. Further, this tight sealing of the cell membrane prevents ions from escaping into the bath solution in which the cell is suspended.

Different Patch-clamp Methods:

Depending upon the research interest, several variations of the patch-clamp method can be used for measuring the cell's biophysical properties. For example, researchers can clamp or control the membrane voltage and measure the current passing through it. Alternatively, they can clamp the current and measure any variation in the membrane voltage.

In cell-attached mode, the membrane patch containing a single or a few ion channels remains intact. As a result, the current flowing through the membrane patch alone can be measured. In contrast, the whole-cell method involves disruption of the membrane patch by briefly applying strong suction. Consequently, the interior of the pipette becomes continuous with the cytoplasm. This mode enables the measurement of electrical current and voltage from the entire cell.

Another patch-clamp method requires gentle retraction of the attached pipette. As a result, the membrane patch is excised without affecting the tight seal. In this inside-out configuration, the intracellular portion of the membrane is exposed to the bath solution, allowing the study of intracellular factors affecting the channel functions.

Tags
Patch ClampCell MembraneIon ChannelsCurrent MeasurementVoltage MeasurementCell attached ModeWhole cell ModeInside out ConfigurationBiophysical PropertiesElectrophysiology

Dal capitolo 14:

article

Now Playing

14.11 : Patch Clamp

Channels and the Electrical Properties of Membranes

5.2K Visualizzazioni

article

14.1 : Acquaporine

Channels and the Electrical Properties of Membranes

4.6K Visualizzazioni

article

14.2 : Canali ionici non gate

Channels and the Electrical Properties of Membranes

6.5K Visualizzazioni

article

14.3 : Canali ionici ligando-dipendenti

Channels and the Electrical Properties of Membranes

12.0K Visualizzazioni

article

14.4 : Canali ionici voltaggio-dipendenti

Channels and the Electrical Properties of Membranes

7.7K Visualizzazioni

article

14.5 : Canali ionici con gate meccanico

Channels and the Electrical Properties of Membranes

6.0K Visualizzazioni

article

14.6 : Struttura dei neuroni

Channels and the Electrical Properties of Membranes

12.1K Visualizzazioni

article

14.7 : Potenziale di membrana a riposo

Channels and the Electrical Properties of Membranes

16.6K Visualizzazioni

article

14.8 : Decadimento del potenziale di riposo

Channels and the Electrical Properties of Membranes

4.5K Visualizzazioni

article

14.9 : Potenziale d'azione

Channels and the Electrical Properties of Membranes

7.2K Visualizzazioni

article

14.10 : Canale Rodopsine

Channels and the Electrical Properties of Membranes

2.5K Visualizzazioni

article

14.12 : Sinapsi elettriche

Channels and the Electrical Properties of Membranes

7.8K Visualizzazioni

article

14.13 : Sinapsi chimiche

Channels and the Electrical Properties of Membranes

8.3K Visualizzazioni

article

14.14 : Effetti eccitatori e inibitori dei neurotrasmettitori

Channels and the Electrical Properties of Membranes

9.2K Visualizzazioni

article

14.15 : Contrazione muscolare

Channels and the Electrical Properties of Membranes

5.9K Visualizzazioni

See More

JoVE Logo

Riservatezza

Condizioni di utilizzo

Politiche

Ricerca

Didattica

CHI SIAMO

Copyright © 2025 MyJoVE Corporation. Tutti i diritti riservati