1. Preparation of 7-47% sucrose gradients
- Prepare sucrose gradients one day before use to allow gradients to become continuous. Make sterile 7% and 47% sucrose solutions containing 50mM NH4Cl, 50mM Tris-Acetate pH 7.0 and 12mM MgCl2 and store at 4°C 1.
- For 6 gradients mix the 7% and 47% sucrose stock solutions to make 48 mL of each of the following sucrose concentrations. Add DTT (1M stock) to each sucrose solution to a final concentration of 1mM.
Final Concentration | 7% sucrose | 47% sucrose |
7% | 48 mL | 0 |
17% | 36 mL | 12 mL |
27% | 24 mL | 24 mL |
37% | 12 mL | 36 mL |
47% | 0 | 48 mL |
- In order to pour the gradients, attach a Pasteur pipette to a 20 mL syringe by securing and sealing with Parafilm or use a long needle. Add 7 mL of 7% sucrose to the bottom of a 1 x 3.5" polyallomer ultracentrifuge tube. Next add 7 mL of 17% sucrose solution under the 7% solution by placing the Pasteur pipette tip near bottom of tube and pipetting no faster than 0.3 mL/sec. Repeat with 7 mL each of 27%, 37% and 47% sucrose solutions. You should observe clear lines between the layers, indicating that minimal mixing has occurred. Store gradients at 4°C overnight along with the rotors, bottles and tubes that will be used to harvest samples.
2. Preparation of the yeast extract
- Grow 125 mL of yeast culture to an OD600 of 0.8-1.0. Add cycloheximide to the culture to a final concentration of 100 μg/mL and continue shaking at 30°C for 15 min.
- Meanwhile, prepare lysis buffer containing 80 μg/mL cycloheximide, 200 μg/mL heparin, 0.2% DEPC, and 10 mM Tris-HCl pH 7.5, 0.1M NaCl, 30mM MgCl2. Keep everything on ice from this point on.
- Pour the culture into a 250 mL centrifuge bottle and fill with ice. Centrifuge at 8,000 x g (7,250 rpm in a SLA-1500 rotor) for 5 min at 4°C. Wash the pellet once with 10 mL of ice cold lysis buffer and transfer to 15 mL polypropylene tubes. Centrifuge at 5,900 x g (~6,000rpm in a SLA-600TC rotor) for 3 min at 4°C. Resuspend the pellet in 0.5 mL of lysis buffer, transfer to 1.5mL tube and add 0.5 mL of chilled, baked acid-washed glass beads. Vortex the cells for four 30 sec intervals, cooling the tube on ice for 30 sec between each interval. Add another 0.5 mL of lysis buffer into the 1.5 mL tube. Centrifuge at maximum speed in a microcentrifuge (14,000 rpm in an Eppendorf 5417R microcentrifuge) for 10 min at 4°C. Transfer supernatant to a new 1.5 mL microcentrifuge tube. Remove 10 μl to a separate tube to determine the OD260 / OD280 ratio (see step 3.1 below). Store extracts at -80°C.
3. Preparation of extracts from mammalian cells
- For adherent cells, grow in 100 mm dish to ~70% confluence. You will need one 100 mm dish per 11 ml gradient (typical yield is ~20 OD260 units). Scale the amount linearly for larger or smaller gradient sizes. For non-adherent cells, approximately 1 x 107 cells are needed per 11 ml gradient.
- Prior to lysis, add cycloheximide to 100 μg/mL. Incubate at 37°C for 15 min. Transfer plates to ice and rinse cells twice in ice cold PBS. All future steps MUST be carried out at 0-4°C.
- Remove all traces of PBS by aspiration (let plates drain on an angled bed of ice) and add 1 mL lysis buffer, scrape and transfer to pre-chilled 1.5 mL tube. Lysis buffer components will need to be optimized to the cell type and growth conditions. A good starting buffer would be 20 mM HEPES-KOH, pH 7.4, 15 mM MgCl2, 200 mM KCl, 1% Triton X-100 (v/v), 100 μg/mL cycloheximide, 2 mM DTT, and 1 mg/mL heparin. The key variables are the concentrations of magnesium and potassium chloride as well as the inclusion or exclusion of non-ionic detergents to improve extraction of cytoskeletal or membrane bound polysomes. Lyse cells by passing through 27 gauge syringe needle twice or by 5-10 strokes of dounce homogenization using Type B pestle. The syringe or homogenizer should be pre-chilled prior to use.
- Spin at 14,000 x g for 5 min in refrigerated microcentrifuge. Transfer fresh lysate to the sucrose gradient (for mammalian cells this is made up in lysis buffer lacking Triton X-100 and heparin but otherwise as described in 1.2 and 1.3) or flash freeze in liquid nitrogen for later use.
4. Centrifugation of gradients
- Thaw polyribosome lysates on ice. Determine the concentration of nucleic acid in the lysate by adding the reserved 10 μL sample to 1 mL of water and reading the OD260/OD280 ratio with a spectrophotometer. Typical yield from a yeast culture grown as described is 50 OD units.
- Using a pipette with the tip placed against the wall of the tube near the surface of the gradient, gently layer 25 OD260 units of the lysate on top of the gradient. For a 35 mL gradient 500 μl of lysate is typically loaded. Lysis buffer can be used to assure all gradients are loaded with an equal volume. Lower amounts of material yield better resolution. Using forceps, carefully lower the gradients into buckets of a swinging bucket rotor.
- Centrifuge the gradients at 100,000 x g (23,000 rpm in a Surespin 630 rotor) for 4 hr at 4°C. This protocol can be adapted for smaller volume gradients.
5. Collection of data and fractions
- Approximately 30 min prior to the completion of the 4 hr spin attach the needle to the Model 184 tube piercer. Attach the pen to the online Isco Model UA-5 Absorbance/Fluorescence Monitor. Power on the absorbance monitor to allow a stable baseline to be reached prior to analyzing samples. Electronic acquisition of the polysome profile can easily be obtained by attaching a DI-148U data acquisition unit (DATAQ Instruments) to the chart recorder. Profiles can then be collected in real time and saved for later annotation using the accompanying WinDaq software.
- Fill the syringe pump with 50mL of Fluorinert using the reverse flow, rapid setting. Make sure that there are no air bubbles present. Connect the hose from the syringe to the tube piercer and briefly turn on the flow of Fluorinert at 3 mL/min in the forward direction to clear the hose of any air bubbles.
- Place a waste beaker or series of tubes if collecting fractions under the hose at the end of the flow cell to collect sample run off.
- Carefully remove the polyallomer centrifuge tubes containing the sucrose gradient from centrifuge rotor and place them on ice (pre-form the wells in the ice with an empty tube to avoid disturbing gradients).
- To analyze cell extracts, place the gradient tube on the tube piercer. Connect the top of the tube to the outlet and secure. Raise the bottom stage to the centrifuge tube so that the needle pierces the bottom of the tube. Once the needle has protruded through the bottom of the centrifuge tube, begin the flow of Fluorinert in the forward direction at 6mL/min.
- Once the Fluorinert has begun flowing into the tube, monitor the movement of the needle on the online absorbance monitor. Once the needle begins to move, turn on the chart movement to a speed setting of 60. The monitor will record the OD254 starting with the free material followed by 40S ribosomal subunit detection and continuing through to polyribosome complexes. If you are collecting fractions for RNA or protein analysis, typically 0.2 min fractions are taken (1 mL). For RNA analysis, fractions should be collected directly into tubes containing Trizol (Invitrogen), Phenol or SDS/proteinase K, depending on the preferred method of extraction.
- When the end of the polyribosome profile has been reached, turn off the flow of Fluorinert to the centrifuge tube and stop the chart movement of the absorbance/fluorescence monitor.
- Retract the Fluorinert from the centrifuge tube into the syringe by beginning the flow in the reverse direction at a rapid rate making sure not to draw sucrose from the tube into the syringe. Unscrew the centrifuge tube from the tube piercer, lower the needle, and remove the tube.
- Repeat steps 5.5 through 5.8 for each sucrose gradient.
- When all sucrose gradients have been analyzed, retract the Fluorinert from the hose back into the syringe. Remove each part of fractionator (tube piercer and flow cell) including the waste hose located at the top and rinse well with water.
6. Representative Results

Figure 1. Representative trace of ribosome extract prepared from yeast strain BY4741 (mata his3Δ1 leu2Δ0 met15Δ0 ura3Δ0) in the presence of cycloheximide. The ribosomal extract was fractionated utilizing a 7 47% sucrose gradient and analyzed using a pump syringe apparatus attached to a UV detector. Peaks containing polyribosomes and 80S, 60S and 40S ribosomes are indicated.