A subscription to JoVE is required to view this content. Sign in or start your free trial.
Method Article
An optical system was developed to visualize hepatic microcirculation with FITC-labeled erythrocytes and to measure the partial pressure of oxygen in the microvessels with laser-assisted phosphorimetry. This method can be used to investigate physiological and pathological mechanisms by analyzing microvascular structure, diameter, blood flow velocity, and oxygen tension.
There is a considerable discrepancy between oxygen supply and demand in the liver because hepatic oxygen consumption is relatively high but about 70% of the hepatic blood supply is poorly oxygenated portal vein blood derived from the gastrointestinal tract and spleen. Oxygen is delivered to hepatocytes by blood flowing from a terminal branch of the portal vein to a central venule via sinusoids, and this makes an oxygen gradient in hepatic lobules. The oxygen gradient is an important physical parameter that involves the expression of enzymes upstream and downstream in hepatic microcirculation, but the lack of techniques for measuring oxygen consumption in the hepatic microcirculation has delayed the elucidation of mechanisms relating to oxygen metabolism in liver. We therefore used FITC-labeled erythrocytes to visualize the hepatic microcirculation and used laser-assisted phosphorimetry to measure the partial pressure of oxygen in the microvessels there. Noncontact and continuous optical measurement can quantify blood flow velocities, vessel diameters, and oxygen gradients related to oxygen consumption in the liver. In an acute hepatitis model we made by administering acetaminophen to mice we observed increased oxygen pressure in both portal and central venules but a decreased oxygen gradient in the sinusoids, indicating that hepatocyte necrosis in the pericentral zone could shift the oxygen pressure up and affect enzyme expression in the periportal zone. In conclusion, our optical methods for measuring hepatic hemodynamics and oxygen consumption can reveal mechanisms related to hepatic disease.
1. Labeling Erythrocytes with Fluorescein Isothiocyanate Isomer I (FITC)
All the experimental protocols we used were approved by the Animal Care Committee of Keio University School of Medicine.
2. Preparation of Oxygen-sensitive Dye
3. Animal Preparation
4. Blood Flow Visualization
5. pO2 Measurement
Pd-TCPP phosphorescence is relatively weak and should be detected with a high–sensitivity detector. All experiments need to be performed in a dark room.
6. Hepatitis Model
7. Representative Results
Example images of hepatic microcirculation are shown in Figure 1, where (a) is a transmitted–light image and (b) is a fluorescence image. Individual FITC-labeled erythrocytes are observed in the video movie, and portal venules, sinusoids, and central venules are recognized by blood flow directions.
As shown in Figure 2, the laser spot irradiating a central venule through a x100 objective lens was approximately 10 μm in diameter. Intravascular pO2 in the hepatic microcirculation was measured in male C57BL/6 mice, and Figure 3(a) shows the relations between pO2 and vessel diameter in portal and central venules. The pO2 gradient from portal to central venules indicates that RBCs release oxygen efficiently while passing through sinusoids. As shown in Figure 3(b), the average pO2 was 59.8 mmHg in portal vessels, 48.2 mmHg in sinusoids, and 38.9 mmHg in central venules.
When we produced acute hepatitis by injecting APAP intraperitonealy, intravascular pO2 was significantly elevated in each part of the hepatic microcirculation: p<0.05 in portal veins and p<0.01 in sinusoids and central veins (Figure 3(c)).
Figure 1. Low-magnification images showing hepatic microcirculation with (a) transmitted light and (b) fluorescence.
Figure 2. Image of laser spot irradiating a targeted central venule for pO2 measurement.
Figure 3. pO2 gradient in hepatic microcirculation of healthy control mice and of mice with acetaminophen-induced hepatic injury. (a) shows pO2 versus vessel diameter for portal venules (PV) and central venules (CV), and (b) shows the oxygen gradient from PV to CV via sinusoids (S). The pO2 difference between PV and CV reflects the oxygen consumption of hepatocytes or other parenchymal cells. (c) shows that in hepatitis conditions induced by APAP administration, pO2 was significantly elevated in PV, S, and CV and the pO2 gradient decreased, indicating that hepatic oxygen consumption was compromised.
Access restricted. Please log in or start a trial to view this content.
Delivering oxygen to tissues is an essential role of the microcirculation, and a lot of papers describe diseases related to microvessel anatomy and rheology6. Liver blood flow is a combination of arterial and venous blood. About 30% of the blood flow to the liver is well-oxygenated blood provided by the hepatic artery and the other 70%, provided by the portal vein, is the poorly oxygenated blood venous outflow from the spleen and gastrointestinal tract7. Liver diseases such as fatty liver, shock, or...
Access restricted. Please log in or start a trial to view this content.
We have nothing to disclose.
Authors thank Ms. Risa Otsuka for technical assistance and helping experiments. This research was partially supported by the Ministry of Education, Science, Sports and Culture, Grant-in-Aid for Young Scientists (B), 2010, 22700476, and Suzuken Memorial Foundation 2010 for K.T. And this study was supported by Research and Development of the Next-Generation Integrated Simulation of Living Matter, a part of the Development and Use of the Next-Generation Supercomputer Project of MEXT, and in part by JST ERATO Suematsu Gas Biology Project.
Access restricted. Please log in or start a trial to view this content.
Name | Company | Catalog Number | Comments |
Pd(II) meso-Tetra(4-carboxyphenyl)porphine | Frontier Scientific, Inc. | PdT790 | |
Fluorescein isothiocyanate isomer I | Sigma-Aldrich Co. | F7250 | |
Acetaminophen | Sigma-Aldrich Co. | A7085 | |
Equipment | |||
photomultiplier tube | hamamatsu photonics k.k | H10722-20 |
Access restricted. Please log in or start a trial to view this content.
Request permission to reuse the text or figures of this JoVE article