JoVE Logo

Sign In

A subscription to JoVE is required to view this content. Sign in or start your free trial.

In This Article

  • Summary
  • Abstract
  • Introduction
  • Protocol
  • Results
  • Discussion
  • Disclosures
  • Acknowledgements
  • Materials
  • Reprints and Permissions

Summary

The utilization of 3D reconstruction and virtual simulations in preoperative planning for liver resections represents a significant advancement in surgical oncology. Our team's 3D-LAST (three-dimensional location approach with the silk thread) technique enables safe, efficient, precise tumor removal with practical intraoperative navigation, promising broad medical adoption.

Abstract

When performing hepatectomy to treat liver tumors, accurately determining the resection margin and ensuring the adequacy of residual liver parenchyma are of utmost importance. At present, intraoperative ultrasound and indocyanine green fluorescence navigation are frequently utilized methods. However, certain technical constraints prevent their extensive application. We have developed the 3D-LAST technique for precise liver tumor resection. This technique makes use of computer post-processing to extract features from computed tomography (CT) scans and generate volumetric images, creating three-dimensional (3D) visualizations. This provides a valuable resource for clinical decision-making, as it can vividly display complex internal anatomical structures in an intuitive and stereoscopic manner. In this study, preoperative 3D positioning was carried out on patients with a single liver tumor to identify anatomical landmarks and calculate the resection range. During the surgical procedure, margin lines of lengths calculated by preoperative 3D software were set up, and silk thread was used to mark the edges. This approach offers a time-saving and accurate way to determine the optimal cutting plane. The objective of this article is to demonstrate the viability of applying 3D-LAST in laparoscopic segmentectomy for liver tumors. The results of the research indicate that 3D-LAST is a safe, effective, and practical new method for intraoperative liver navigation, and it has great potential for widescale promotion.

Introduction

Hepatectomy remains a cornerstone treatment for liver tumors. Over recent decades, surgical approaches have evolved from irregular resections to precise anatomical resections, driven by advancements in assistive technologies such as intraoperative ultrasound (IOUS) and indocyanine green (ICG) fluorescence imaging1,2. Despite these innovations, achieving optimal resection margins while preserving sufficient functional liver volume remains a critical challenge. The overall goal of our proposed 3D-LAST (three-dimensional location approach with silk thread) technique is to provide a precise, cost-effective, and universally accessible intraoperative navigation method for liver tumor resection, minimizing reliance on specialized equipment while improving spatial accuracy.

The rationale for developing 3D-LAST stems from the limitations of current techniques. IOUS, while valuable for real-time tumor localization, requires skilled sonographers for image interpretation and struggles with two-dimensional (2D) spatial visualization, often prolonging operative time3,4. ICG fluorescence navigation, though effective for superficial tumors, is constrained by its limited tissue penetration depth (5-10 mm), rendering it unreliable for deeper lesions5,6. Both methods depend on costly, specialized hardware, limiting their adoption in resource-constrained settings.

The advantages of 3D-LAST over existing techniques are multifaceted. Three-dimensional visualization, derived from preoperative computed tomography (CT) reconstructions, overcomes the spatial ambiguity of 2D imaging by providing stereoscopic anatomical guidance. Unlike ICG, which lacks depth resolution, 3D-LAST enables precise volumetric resection planning, reducing the risk of positive margins or excessive parenchymal loss. Furthermore, the use of silk thread for intraoperative marking eliminates the need for real-time imaging devices, streamlining workflow and reducing costs.

3D-LAST is particularly suited for centers lacking advanced imaging infrastructure or expertise in complex intraoperative navigation. It is ideal for single-tumor resections where anatomical landmarks are identifiable on preoperative CT and where minimizing procedural complexity is prioritized. By addressing the limitations of current methods and leveraging validated 3D technologies, 3D-LAST represents a pragmatic advancement in achieving precision liver surgery with broad clinical adaptability.

Case Presentation:
A 59-year-old man with upper abdominal discomfort was diagnosed with a 2.7 cm x 1.6 cm liver tumor in the right liver. The patient was previously diagnosed with gastric adenocarcinoma and underwent radical gastrectomy for gastric cancer, followed by routine chemotherapy. No extrahepatic metastasis was found on the preoperative contrast-enhanced CT scan. CA19-9, CA15-3, CA72-4, AFP, and CEA were normal.

Protocol

The study was approved by the review committee of West China Hospital of Sichuan University. Informed consent was obtained from the patient before the surgery.

1. Preoperative preparation

  1. Obtain high-resolution CT scans of the patient liver in DICOM format (Figure 1A).
  2. Launch the Mimics software, create a new project, and import the DICOM files to ensure all image data is correctly loaded for 3D reconstruction and analysis.
  3. Reconstruct the three-dimensional structure of the liver, vessels, and tumor. Mark the liver in pink, the portal vein in blue, the artery in red, the hepatic vein and inferior vena cava in blue, and the tumor in yellow (Figure 1B).
  4. Place three small virtual sticks on the 3D liver model and obtain four key points (S1, S2, S3, S4) on the surface of liver (Figure 2A-B).
    1. These virtual sticks act as digital landmarks, guiding the surgeon in determining the precise location and orientation of the intended cut. Place the virtual stick marking of the resection point at 1 cm from the tumor margin and the midpoint of the edge of the liver at the bottom of the gallbladder.
      NOTE: By marking these key points, surgeons can ensure they remain focused on the target area during surgery, minimizing the risk of unnecessary tissue damage.
  5. Connect the four key points with lines on the liver surface and measure their lengths (S1-S2 = 9.8 cm, S1-S3 =7.2 cm, S2-S3 = 10.4 cm, S4-S2 = 8.2 cm, S4-S3 = 6.5 cm) as shown in Figure 2C-D. These lines represent the proposed resection path, guiding the surgeon in visualizing the shape and contour of the liver after the resection.
    1. Measure the length of each line meticulously to ensure accuracy and consistency. This measurement is crucial as it allows surgeons to prepare silk threads of the exact same length, which will be used intraoperatively to guide the liver cut.

2. Operative procedure

  1. Position the patient supine, with their legs spread and inclined to the right (Figure 3A). Administer standard general anesthesia, including tracheal intubation and controlled ventilation.
  2. Disinfect the skin with 0.5% iodine-based scrub 3x on the area of inter-nipple connection, symphysis pubis, right midaxillary, and left midclavicular lines.
  3. Arrange the surgical team with the surgeon on the right and the assistant on the left. Position the camera centrally among the trocar sites, with the camera holder standing in the middle as well.
  4. Make a 12 mm incision below the umbilicus as the laparoscopic hole (H1), one 12 mm and one 5 mm curved incision (H2 and H3) as the main operating holes, another one 12 mm and one 5 mm (H4 and H5) as the auxiliary operating holes (Figure 3B).
  5. Insert five trocars (12 mm, 12 mm, 12 mm, 5 mm, and 5 mm) into incisions as depicted in Figure 3B. Turn on the pneumoperitoneum system and inject 100% carbon dioxide gas through the trocar to maintain the pneumoperitoneum at a pressure of about 12 mmHg.
  6. Conduct an exploratory examination of the abdominal cavity, starting from the left epigastrium and moving rightwards down to the hypogastrium, to detect any presence of ascites, cirrhosis, and metastasis.
  7. Free abdominal adhesions, detach the round ligament of the liver, free the right hepatic ligament and adhesions, and fully expose the liver segment V using an ultrasonic knife.
  8. Use an ultrasonic knife to dissect the gallbladder triangle, revealing the gallbladder duct and artery. Subsequently, ligate these structures with small hemo-lock clips before excising the gallbladder.
  9. Prepare three silk threads with lengths of S1-S2 = 9.8 cm, S1-S3 = 7.2 cm, and S2-S3 = 10.4 cm respectively. Point S4 is located at the neck of the gallbladder, so prepare no silk threads for S4-S2 = 8.2 cm and S4-S3 = 6.5 cm.
  10. Place the three silk threads at the anatomical position on the liver surface, corresponding to the preoperatively planned resection path, as shown in Figure 4. By using silk threads as a physical guide, surgeons can visualize and follow the planned resection path with greater precision during surgery.
    NOTE: This step bridges the gap between the virtual planning and the actual surgical procedure.
  11. Use an electric knife to cauterize the liver by cutting markers along the silk thread on the surface of the liver (Figure 4D) and sew a rubber band on the liver for traction (Figure 5A).
  12. Use an ultrasonic knife to transect the liver parenchyma along the marker lines. Cut vessels that are encountered by home-o-lock clipping, use an aspirator to suction the blood, and use bipolar forceps to stop bleeding (Figure 5B).
  13. Place the specimen in a bag and make a 4cm incision by scalpel at the upper abdomen to remove the specimen. Confirm no active bleeding in the abdominal cavity, place hemostatic materials on the liver transection surface and one drainage tube exiting from the right lower abdomen.
  14. Remove the trocar and suture incisions by 3-0 absorbable sutures layer by layer. Examine the specimen to verify the integrity of the tumor capsule and measure the size of the tumor (Figure 5C-D).

3. Post-hepatectomy management

  1. Transfer the patient to the ward following successful recovery from anesthesia and observe the patient's vital signs using uninterrupted cardiac monitoring during the initial 24 h recovery period following surgery.
  2. Implement prophylactic antimicrobial therapy by intravenous infusion throughout the 1st postoperative day to reduce potential septic complications.
  3. Remove urinary catheterization at 24 h post-procedure. Conduct a plain computed tomography scan 72 h after surgery (Figure 6). Evacuate surgical drains 4 days after the operation without massive ascites and bile leakage.

Results

The total operation time was 150 min, with 50 mL of blood loss that did not require a blood transfusion. Intraoperative urine volume was 500 mL, and intraoperative infusion volume was 800 mL. On the 1st day after surgery, the blood test results showed a mild increase in transaminase levels. CT scan of the abdomen showed complete resection of the liver tumor and no significant ascites 3 days after surgery. The drain was removed on postoperative day 4. The patient had an uneventful postoperative course and was d...

Discussion

With the development of technology and the accumulation of experience, laparoscopic liver resection has become more and more common, and its indications are almost as extensive as those of open surgery. Compared with laparotomy, laparoscopic liver resection has many advantages, such as less pain, fewer perioperative complications, and faster recovery7,8,9. However, laparoscopic liver resection also faces some inherent difficulti...

Disclosures

The authors report no conflict of interest.

Acknowledgements

This work was supported by the Guizhou Provincial Health Commission Science and Technology Fund Project(gzwkj2025-300), the Project of Guizhou Provincial Department of Science and Technology (Qian Ke He Cheng Guo, LC[2024]109 ).

Materials

NameCompanyCatalog NumberComments
BiClamp LAPERBE CompanyNo.20195-132
Laparoscopic systemOlympusVISERA OTV-S400
Ultrasonic knifeJohnson and Johnson MedTechETHICON HARMONIC

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Explore More Articles

Three dimensionalsilk threadlaparoscopic hepatectomyliver tumor

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2025 MyJoVE Corporation. All rights reserved