Sign In

A subscription to JoVE is required to view this content. Sign in or start your free trial.

In This Article

  • Summary
  • Abstract
  • Introduction
  • Protocol
  • Representative Results
  • Discussion
  • Acknowledgements
  • Materials
  • References
  • Reprints and Permissions

Summary

We describe an ex vivo isolated working rat heart protocol to test donor heart preservation strategies. This paper describes the protocol for use in static cold storage of rodent donor hearts; however, the protocol can also be used for donor hearts obtained after donation after circulatory death and brain death.

Abstract

Optimization of donor heart preservation solutions has played a key role in reducing ischemia-reperfusion injury in donor hearts during organ retrieval, transportation, and transplantation. Previous work from our laboratory showed that the addition of glyceryl trinitrate and erythropoietin to donor heart preservation solutions could significantly improve cardiac functional recovery after prolonged cold storage and in donation after circulatory death hearts. This supplementation protocol has been implemented in clinical use in transplant units around Australia, Belgium, and the United Kingdom. Here, we outline a protocol for testing supplementation strategies using an ex vivo isolated working rat heart (IWRH) perfusion circuit. Using this methodology, supplementation strategies can be tested in the context of prolonged cold static storage, donation after brain death, and donation after circulatory death donor heart preservation. Cardiac functional recovery, measured by aortic flow, coronary flow, cardiac output, pulse pressure, and heart rate, can be used to determine whether a particular preservation strategy can minimize ischemia-reperfusion injury of the donor heart.

Introduction

The success of a heart transplant can be greatly influenced by the preservation method used for the donor heart. Donor hearts are subjected to ischemic insults throughout the organ retrieval, transport, and transplantation process. The degree of ischemic damage to the donor organ can be mitigated by selecting an appropriate donor heart preservation strategy. Cold static storage (CSS) remains the most feasible and common method for donor heart preservation; however, CSS may not necessarily be the best option for all heart donation pathways. For example, hearts procured via the donation after circulatory death (DCD) pathway are maintained and assessed for viability usin....

Protocol

All animals received humane care in compliance with the National Health and Medical Research Council (Australia) guidelines. All animal procedures were approved by the Animal Ethics Committee of the Garvan Institute of Medical Research (Sydney, Australia).

1. Preparation of Krebs-Henseleit (KH) buffer

  1. Prepare 2 L of a 20x stock solution of KH buffer containing 2.36 M NaCl, 0.094 M KCl, 0.024 M MgSO4, 0.024 M KH2PO4. Aliquot into 50 .......

Representative Results

The results from the baseline perfusion will determine whether the initial experiment (pre-storage) was successful. The aortic flow displayed during Langendorff mode should be between 14 - 22 mL/min. Langendorff flow is displayed as a negative value on the flow meter due to the retrograde perfusion of the aorta. An example of an acceptable Langendorff trace is shown in Figure 4A.

Once switched to working mode, the aortic flow should be at least 30 mL/min once the .......

Discussion

Given the sensitive nature of heart baseline function, care must be taken to maintain the perfusion rig clean and with compatible components. For example, the correct PVC tubing must be used. Some tubing materials, such as silicone, can contribute to lower aortic flow and contractility, which may be due to loss of oxygen via the tubing. While there are isolated working rat heart perfusion circuits commercially available, most of these are primarily used for Langendorff perfusion only. Generally, functional measurements c.......

Acknowledgements

The studies described here have been funded by grants awarded to P.S Macdonald from the National Health and Medical Research Council Australia, the St Vincent's Clinic Foundation, and the NSW Health Cardiovascular Research Capacity Senior Investigator Grant.

....

Materials

NameCompanyCatalog NumberComments
1.5 mL colorless Eppendorff tube, 1000 per boxBio Strategy Pty Ltd0030.125.150
15 mL cent/tubes (S) Sleeve/25 PP ctn/500Sigma-aldrich Pty LtdCLS430791-500ea
BP Transducer/Cable kitADInstrumentsMLT1199Data Acquisition
Bridge AmpADInstrumentsFE221Data Acquisition
Carbogen 555G2BOCBOC002
Checktemp1 thermometerHanna InstrumentsHI98509Rig Construction
Clamp Pinch 1/4-7/16 PK 12Thomas Scientific2848Y40Rig Construction
Clamp W/Extension Stem Med.Thomas Scientific8847T08Rig Construction
Clamp W/Extension Stem Sm.Thomas Scientific8847T02Rig Construction
Clips, Vessel, 60 g PressureCoherent Scientific14121Surgical Equipment
Closed ConnectorThomas Scientific8847E25Rig Construction
Covidien Sofsilk 2-0 black precut 45 cm box of 24Specialist Medical SuppliesS195Surgical consumables
Custom Made 250 mL Jacketed DegasserCustom Blown Glassware Pty LtdN/ARig Construction
Custom Made 750 mL ReservoirCustom Blown Glassware Pty LtdN/ARig Construction
D-(+)-Glucose Anhydrous SigmaUltraSigma-aldrich Pty LtdG7528-1KgTo make Krebs Buffer
Dual Channel ConsoleADInstrumentsTS402Data Acquisition
Erlenmyer flasks 2 L 
Filter Microfibre type GF/C glass fibre 47 mm, 100Bio-strategy Pty Ltd1822047
Forceps, 15 cm, 0.3 mm, CRVDCoherent Scientific14114Surgical Equipment
Four Prong Clamps with 9 mm x 115 mm long arm for holding 2-70 mm diam objects. Vinyl coatedMet-App Australia Pty Ltd1352Rig Construction
Heater Circulator. Digital Solid State Control. (1020 Watts/240 Volts)Thermoline ScientificTU3Rig Construction
Heparin 5000 U/5 mL box 50 Pfizer 02112115Clffird Hallam Healthcare Pty Ltd1258693Drugs
Ilium Xylazil 20 Inj 50 mLCenvet Australia Pty LtdX5010Anaesthetic
Johns Hopkins Bulldog ClampCoherent Scientific CS-WPI-14117
Ketamine 100 mg/50 mLProvet (NSW) Pty LtdKETAI1Anaesthetic
Magnesium Sulphate heptahydrate AR 500 g ChemsupplyBio Strategy Pty LtdMA048-500gTo make Krebs Buffer
Male/Female Hinged AdapterThomas Scientific8847V08Rig Construction
Masterflex L/S Easy-Load Head for Precision Tubing, PPS, CRS RotorJohn Morris1015164Rig Construction
Metzenbaum scissors, 11.5 cm curvedCoherent ScientificWPI-501748Surgical Equipment
Metzenbaum scissors, 14.5 cm straightCoherent ScientificWPI-501252Surgical Equipment
Mounting Hardware F/2-HEADS SSJohn Morris1014414Mounting screws for pump heads
Open-sided connectorThomas Scientific8847E05Rig Construction
ParaformadehydeSigma-AldrichP6148-500GSample processing
Potassium Chloride (AnalaR NORMAPUR) 500 gVWR Chemicals 26764.26To make Krebs Buffer
Potassium phosphate monobasic Sigma-Aldrich Pty LtdP5379-500gTo make Krebs Buffer
Powerlab 2/26, 2 channel recorder + Labchart softwareADInstrumentsML826Computer Hardware and Software
Precision XN Inline Flowsensor, 3.2 mm (1/8")ID ME4PXN-KR37 XFADInstrumentsME4PXNRig Construction
Scalpel with handle disposable #11 pkt/10BSN Medical (Aust) Pty Ltd73252-36
Silicone Gasket for Swinnex 47 mm 5/PKMerck MilliporeSX0004701Rig Construction
Silicone O-Ring 5-329 10/PKMerck MilliporeXX1104707Rig Construction
Single Buret ClampThomas Scientific8847T32Rig Construction
Slip-on inlet Filter pore size 10 µm (bubbler)Sigma-aldrich59277Rig Construction
Sm. 360 Rotation ConnectorThomas Scientific8847E35Rig Construction
Sodium bicarbonateSigma-Aldrich Pty LtdS6297 - 250gTo make Krebs Buffer
Swinnex Filter Holder, 47 mmMerck MilliporeSX0004700Rig Construction
syringes 1 mL box/100Becton Dickinson Pty Ltd302100
Three Prong Clamps with 9 mm diameter x 125 mm long arm and twin screw for holding 5-80 mmMet-App Australia Pty Ltd1356Rig Construction
Tubing Flowmeter Module TS410ADInstrumentsTS410Data Acquisition
Tubing PVC 6.35 mm ID x 9.52 mm OD 50ft Roll 15.24m, clear , DEHP phthalate free, food grade meets REACThermo FisherNAL 8701-0600Rig Construction
Tubing PVC 7.94mm ID x 11.1mm OD 50ft Roll 15.24 m, clear , DEHP phthalate free, food grade meets REACThermo FisherNAL 8701-0900Rig Construction
Tubing PVC 9.52 mm ID x 12.7 mm OD 100ft RollThermo FisherNAL 8701-4120Rig Construction
Vannas scissors, 8.5 cm, Straight, 7 mm BladesCoherent ScientificWPI-500-086Surgical Equipment
Water Bath 30 Litre with Suspended TrayThermoline ScientificTLWB-30Rig Construction

References

  1. Kwan, J. C., Gao, L., Macdonald, P. S., Hicks, M. Cardio-protective signalling by glyceryl trinitrate and cariporide in a model of donor heart preservation. Heart Lung Circ. 24 (3), 306-318 (2015).
  2. Watson, A. J., et al.

Explore More Articles

Medicine

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2024 MyJoVE Corporation. All rights reserved