JoVE Logo

Accedi

University of Montana

7 ARTICLES PUBLISHED IN JoVE

image

Environment

Quantifying Corticolous Arthropods Using Sticky Traps
Michael W. Eichholz *1, Elise C. Zarri *2, Kevin P. Sierzega *1
1Cooperative Wildlife Research Laboratory, Center for Ecology, Department of Zoology, Southern Illinois University, 2Montana Cooperative Research Unit, University of Montana

We describe a semi-quantitative approach of measuring characteristics of corticolous (bark-dwelling) arthropod communities. We placed commercially manufactured sticky traps on tree boles to estimate abundance, total length (a surrogate to biomass), richness, and Shannon diversity for comparison among tree species.

image

Developmental Biology

In Situ Detection of Ribonucleoprotein Complex Assembly in the C. elegans Germline using Proximity Ligation Assay
Nicholas J. Day 1, Xiaobo Wang 1, Ekaterina Voronina 1
1Division of Biological Sciences, University of Montana

This protocol demonstrates use of the proximity ligation assay to probe for protein-protein interactions in situ in the C. elegans germline.

image

Biochemistry

Resin-Assisted Capture Coupled with Isobaric Tandem Mass Tag Labeling for Multiplexed Quantification of Protein Thiol Oxidation
Matthew J. Gaffrey 1, Nicholas J. Day 1, Xiaolu Li 2, Wei-Jun Qian 1
1Integrative Omics, Biological Sciences Division, Pacific Northwest National Laboratory, 2Bioproducts Sciences and Engineering Laboratory, Department of Biological Systems Engineering, Washington State University

Protein thiol oxidation has significant implications under normal physiological and pathophysiological conditions. We describe the details of a quantitative redox proteomics method, which utilizes resin-assisted capture, isobaric labeling, and mass spectrometry, enabling site-specific identification and quantification of reversibly oxidized cysteine residues of proteins.

image

Medicine

Standardized Rat Coronary Ring Preparation and Real-Time Recording of Dynamic Tension Changes Along Vessel Diameter
Pengmei Guo *1, Wenqiao An *2, Ying Guo 1, Zhihao Sun 2, Xiaobo Wang 1,3, Sanyin Zhang 1,3
1Innovative Institute of Chinese Medicine and Pharmacy, Chengdu University of Traditional Chinese Medicine, 2School of Basic Medicine, Chengdu University of Traditional Chinese Medicine, 3Research Institute of Integrated TCM & Western Medicine, Chengdu University of Traditional Chinese Medicine

The present protocol describes the wire myograph technique for measuring vascular reactivity of the rat coronary artery.

image

Neuroscience

Real-Time Dynamic Collection of Hippocampal Extracellular Fluid from Conscious Rats Using a Microdialysis System
Xiaobo Wang 1,2, Na Xie 3, Yi Zhang 4, Xianli Meng 1,2,3, Ya Hou 3, Sanyin Zhang 1,2
1Innovative Institute of Chinese Medicine and Pharmacy, Chengdu University of Traditional Chinese Medicine, 2Research Institute of Integrated TCM & Western Medicine, Chengdu University of Traditional Chinese Medicine, 3School of Pharmacy, Chengdu University of Traditional Chinese Medicine, 4School of Ethnic Medicine, Chengdu University of Traditional Chinese Medicine

The protocol here provides a detailed real-time dynamic sampling of extracellular fluid from the hippocampus of awake rats using a microdialysis system.

image

Medicine

Dynamic Continuous Blood Extraction from Rat Heart via Noninvasive Microdialysis Technique
Ya Hou 1, Jinrong Bai 1,2, Yi Zhang 3, Xianli Meng 1,2,4, Sanyin Zhang 4, Xiaobo Wang 2
1School of Pharmacy, Chengdu University of Traditional Chinese Medicine, 2Research Institute of Integrated TCM & Western Medicine, Chengdu University of Traditional Chinese Medicine, 3School of Ethnic Medicine, Chengdu University of Traditional Chinese Medicine, 4Innovative Institute of Chinese Medicine and Pharmacy, Chengdu University of Traditional Chinese Medicine

The present protocol describes a simple and efficient method for the real-time and dynamic collection of rat heart blood using the microdialysis technique.

image

Medicine

Voltage-Dependent Potassium Current Recording on H9c2 Cardiomyocytes via the Whole-Cell Patch-Clamp Technique
Hong Jiang *1, Yating Zhang *1, Ya Hou 1, Lijun Li 2, Sanyin Zhang 3,4, Yi Zhang 5, Xianli Meng 1,3,4, Xiaobo Wang 4
1State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, 2Chengdu Techman Instrument Co., Ltd., 3Innovative Institute of Chinese Medicine and Pharmacy, Chengdu University of Traditional Chinese Medicine, 4Research Institute of Integrated TCM & Western Medicine, Chengdu University of Traditional Chinese Medicine, 5School of Ethnic Medicine, Chengdu University of Traditional Chinese Medicine

The present protocol describes an efficient method for the real-time and dynamic acquisition of voltage-gated potassium (Kv) channel currents in H9c2 cardiomyocytes using the whole-cell patch-clamp technique.

JoVE Logo

Riservatezza

Condizioni di utilizzo

Politiche

Ricerca

Didattica

CHI SIAMO

Copyright © 2024 MyJoVE Corporation. Tutti i diritti riservati