JoVE Logo

로그인

20.19 : Joule-Thomson Effect

The Joule-Thomson effect, also known as the Joule-Kelvin effect, describes the temperature change of a fluid when it is forced through a valve or porous plug while keeping it in a thermally insulated environment. This experiment is called a throttling process. This is an important effect widely used in refrigeration and the liquefaction of gases.

This experiment forces high-pressure gas through a throttle valve or a porous plug to a lower-pressure region. The gas expands as it passes through to the low-pressure region and occupies the volume, which is larger than the initial volume. Work is done on the gas when gas is forced through a throttle valve. However, when it expands, work is done by the gas on the surroundings. The temperature of the gas varies in this process; hence, it attains a new internal energy. The change in internal energy of the gas must be equal to the work done on the gas minus the work done by the gas. It is found that enthalpy is conserved (isenthalpic) in this flow process.

The change in temperature of the gas when pressure is reduced at constant enthalpy is given by the Joule-Thomson coefficient:

Thermometer schematic diagram showing constant-volume gas thermometer pressure-temperature relationship.

Since the temperature of the gas varies, the Joule-Thomson coefficient can take either sign, depending on whether the gas becomes heated or cooled. The inversion curve in the T-p plane explains the heating and cooling of gas during the throttling process.

Joule-Thomson effect diagram with isenthalps, inversion curve showing cooling and heating phases.

The inversion curve separates the region of heating from the region of cooling. The maxima of the different isenthalps lie on the inversion curve. Note that an isenthalp is the locus of the end points of different throttling processes, starting at the same initial state. Depending on where the initial and final points are chosen, both heating and cooling effects can be produced during the throttling process.

The Joule-Thomson coefficient is zero for an ideal gas, indicating there is no temperature change when an ideal gas undergoes a throttling process. The coefficient is negative for real gases at extremely high and extremely low temperatures.

Tags

Joule Thomson EffectJoule Kelvin EffectTemperature ChangeThrottling ProcessRefrigerationLiquefaction Of GasesHigh pressure GasThrottle ValveInternal EnergyWork DoneEnthalpy ConservationIsenthalpic ProcessJoule Thomson CoefficientInversion CurveHeating And Cooling EffectsIdeal Gas

장에서 20:

article

Now Playing

20.19 : Joule-Thomson Effect

The First Law of Thermodynamics

2.9K Views

article

20.1 : 열역학 시스템

The First Law of Thermodynamics

4.9K Views

article

20.2 : 볼륨 변경 중 수행된 작업

The First Law of Thermodynamics

3.9K Views

article

20.3 : Path Between Thermodynamics States

The First Law of Thermodynamics

3.0K Views

article

20.4 : 열 및 자유 팽창

The First Law of Thermodynamics

1.7K Views

article

20.5 : 내부 에너지

The First Law of Thermodynamics

4.5K Views

article

20.6 : 열역학 제1법칙

The First Law of Thermodynamics

4.1K Views

article

20.7 : 열역학 제1법칙: 문제 해결

The First Law of Thermodynamics

2.5K Views

article

20.8 : 순환 프로세스와 고립된 시스템

The First Law of Thermodynamics

2.7K Views

article

20.9 : 등온 공정

The First Law of Thermodynamics

3.5K Views

article

20.10 : 등코릭 및 등압 과정

The First Law of Thermodynamics

3.3K Views

article

20.11 : 이상 기체의 열용량 I

The First Law of Thermodynamics

2.6K Views

article

20.12 : 이상 기체 II의 열용량

The First Law of Thermodynamics

2.4K Views

article

20.13 : 이상 기체 III의 열용량

The First Law of Thermodynamics

2.1K Views

article

20.14 : 이상 기체를 위한 단열 공정

The First Law of Thermodynamics

3.0K Views

See More

JoVE Logo

개인 정보 보호

이용 약관

정책

연구

교육

JoVE 소개

Copyright © 2025 MyJoVE Corporation. 판권 소유