Non-restraining EEG radiotelemetry is a valuable methodological approach to record in vivo long-term electroencephalograms from freely moving rodents. This detailed protocol describes stereotaxic epidural and deep intracerebral electrode placement in different brain regions in order to obtain reliable recordings of CNS rhythmicity and CNS related behavioral stages.

Implantable EEG radiotelemetry is of central relevance in the neurological characterization of transgenic mouse models of neuropsychiatric and neurodegenerative diseases as well as epilepsies. This powerful technique does not only provide valuable insights into the underlying pathophysiological mechanisms, i.e., the etiopathogenesis of CNS related diseases, it also facilitates the development of new translational, i.e., therapeutic approaches. Whereas competing techniques that make use of recorder systems used in jackets or tethered systems suffer from their unphysiological restraining to semi-restraining character, radiotelemetric EEG recordings overcome these disadvantages. Technically, implantable EEG radiotelemetry allows for precise and highly sensitive measurement of epidural and deep, intracerebral EEGs under various physiological and pathophysiological conditions. First, we present a detailed protocol of a straight forward, successful, quick and efficient technique for epidural (surface) EEG recordings resulting in high-quality electrocorticograms. Second, we demonstrate how to implant deep, intracerebral EEG electrodes, e.g., in the hippocampus (electrohippocampogram). For both approaches, a computerized 3D stereotaxic electrode implantation system is used. The radiofrequency transmitter itself is implanted into a subcutaneous pouch in both mice and rats. Special attention also has to be paid to pre-, peri- and postoperative treatment of the experimental animals. Preoperative preparation of mice and rats, suitable anesthesia as well as postoperative treatment and pain management are described in detail.

Radiotelemetry is a most valuable methodological approach for measuring a variety of behavioral and physiological parameters in conscious, unrestrained animals of various sizes, particularly in the context of EEG, ECG, EMG, blood pressure, body core temperature or activity measurements 1-7. Theoretically, any species can be analyzed using implantable EEG radiotelemetry from laboratory rodents such as mice and rats to cats, dogs, pigs and primates 3,8. Even fish, reptiles and amphibians are subject to radiotelemetric investigation 9. Over the last two decades, implantable EEG radiotelemetry has proven to be valuable in the characterizat....

Log in or to access full content. Learn more about your institution’s access to JoVE content here

 Ethics Statement: All animal experimentation was performed according to the guidelines of the local and institutional Council on Animal Care (University of Bonn, BfArM, LANUV, Germany). In addition, all animal experimentation was carried out in accordance with superior legislation, e.g., the European Communities Council Directive of 24 November 1986 (86/609/EEC) or individual regional or national legislation. Specific effort is made to minimize the number of animals used and their suffering.

Log in or to access full content. Learn more about your institution’s access to JoVE content here

This section illustrates examples obtained from surface and deep, intracerebral EEG recordings. Initially it should be stated that baseline recordings under physiological conditions are mandatory prior to subsequent recordings following e.g., pharmacological treatment. Such baseline recordings may provide valuable information about functional interdependence of brain rhythmicity with different behavioral states or sleep / circadian rhythmicity. Here, we show examples of recorded .......

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Implantable EEG radiotelemetry is of central relevance as it is a non-restraining technique allowing experimental animals to perform their full repertoire of behavior1,3. This is of major interest as the telemetric approach enables not only spontaneous EEG recordings but also recordings under cognitive tasks and circadian analytical setups, such as T-maze, radial maze, water maze, sleep deprivation tasks or whenever an EEG recording is necessary or helpful during complex cognitive or motor activity.

Log in or to access full content. Learn more about your institution’s access to JoVE content here

The authors would like to thank Dr. Christina Ginkel (German Center for Neurodegenerative Diseases, DZNE), Dr. Michaela Möhring (DZNE) and Dr. Robert Stark (DZNE) for assistance in animal breeding and animal health care. This work was financially supported by the Federal Institute for Drugs and Medical Devices (Bundesinstitut für Arzneimittel und Medizinprodukte, BfArM) Bonn, Germany.

....

Log in or to access full content. Learn more about your institution’s access to JoVE content here

Name Company Catalog Number Comments
Carprofen (Rimadyl VET - InjektionA2:D43slösung) Pfizer PZN 0110208 20 ml
binocular surgical magnification microscope  Zeiss Stemi 2000 0000001003877, 4355400000000, 0000001063306, 4170530000000, 4170959255000, 4551820000000, 4170959040000, 4170959050000
bulldog serrefine F.S.T. 18051-28 28mm
cages (Macrolon) Techniplast 1264C, 1290D
cold light source Schott KL2500 LCD 9.705 202 ordered at Th.Geyer
cotton tip applicators (sterile) Carl Roth  EH12.1
Dexpanthenole (Bepanthen Wund- und Heilsalbe) Bayer PZN: 1578818
drapes (sterile) Hartmann PZN 0366787
70% ethanol Carl Roth  9065.5
0.3% / 3% hydrogene peroxide solution Sigma 95321 30% stock solution 
gloves (sterile) Unigloves 1570
dental glas ionomer cement KentDental /NORDENTA 957 321
2% glutaraldehyde solution Sigma G6257
Graefe Forceps-curved, serrated F.S.T. 11052-10
Halsey Micro Needle Holder-Tungsten Carbide F.S.T. 12500-12 12.5 cm
heat-based surgical instrument sterilizer F.S.T. 18000-50
heating pad AEG HK5510 520010 ordered at myToolStore
high-speed dental drill Adeor SI-1708
Iris scissors extra thin  F.S.T. 14058-09 9 cm
Inhalation narcotic system (isoflurane) Harvard Apparatus GmbH 34-1352, 10-1340, 34-0422, 34-1041, 34-0401, 34-1067, 72-3044, 34-0426, 34-0387, 34-0415, 69-0230
Isoflurane Baxter 250 ml PZN 6497131
Ketamine Pfizer PZN 07506004
lactated Ringer’s solution (sterile) Braun L7502
Lexar-Baby Scissors-straight, 10 cm F.S.T. 14078-10 10 cm
Nissl staining solution Armin Baack BAA31712159
non-absorbable suture material 5-0/6-0 (sterile) SABANA (Sabafil) N-63123-45
Covidien (Sofsilk) S1172, S1173
Halsey Needle Holder F.S.T. 12001-13 13 cm
pads (sterile) ReWa Krankenhausbedarf 2003/01
0.9% saline (NaCl, sterile) Braun PZN:8609255
scalpel blades with handle (sterile) propraxis 2029/10
Standard Pattern Forceps F.S.T. 11000-12, 11000-14 12 cm and 14.5 cm length
Steel and tungsten electrodes parylene coated  FHC Inc., USA) UEWLGESEANND
stereotaxic frame Neurostar 51730M ordered at Stoelting
(Stereo Drive-New Motorized Stereotaxic)
tapes (sterile) BSN medical GmbH & Co. KG 626225
TA10ETA-F20  DSI 270-0042-001X Radiofrequency transmitter 3.9 g, 
3.9 g, 1.9 cc, input voltage range ± 2.5 mV,
channel bandwidth (B) 1-200 Hz, 
nominal sampling rate (f) 1000 Hz (f = 5B)
temperature operating range 34-41 °C
warranted battery life 4 months
TL11M2-F20EET  DSI 270-0124-001X Radiofrequency transmitter 
3.9 g, 1.9 cc, input voltage range ± 1.25 mV,
channel bandwidth (B) 1-50 Hz, 
nominal sampling rate (f) 250 Hz (f = 5B)
temperature operating range 34-41 °C
warranted battery life 1.5 months
Tissue Forceps- 1x2 Teeth 12 cm F.S.T. 11021-12 12 cm length
Tungsten carbide iris scissors F.S.T. 14558-11 11.5 cm
Vibroslicer 5000 MZ Electron Microscopy Sciences 5000-005
Xylazine (Rompun) Bayer PZN: 1320422

  1. Kramer, K., et al. The use of radiotelemetry in small laboratory animals: recent advances. Contemp Top Lab Anim Sci. 40, 8-16 (2001).
  2. Kramer, K., et al. The use of telemetry to record electrocardiogram and heart rate in freely swimming rats. Methods Find Exp Clin Pharmacol. 17, 107-112 (1995).
  3. Kramer, K., Kinter, L. B. Evaluation and applications of radiotelemetry in small laboratory animals. Physiol Genomics. 13, 197-205 (2003).
  4. Kramer, K., Remie, R. Measuring blood pressure in small laboratory animals. Methods Mol Med. 108, 51-62 (2005).
  5. Kramer, K., et al. Use of telemetry to record electrocardiogram and heart rate in freely moving mice. J Pharmacol Toxicol Methods. 30, 209-215 (1993).
  6. Kramer, K., et al. Telemetric monitoring of blood pressure in freely moving mice: a preliminary study. Lab Anim. 34, 272-280 (2000).
  7. Guler, N. F., Ubeyli, E. D. Theory and applications of biotelemetry. J Med Syst. 26, 159-178 (2002).
  8. Aylott, M., Bate, S., Collins, S., Jarvis, P., Saul, J. Review of the statistical analysis of the dog telemetry study. Pharm Stat. 10, 236-249 (2011).
  9. Rub, A. M., Jepsen, N., Liedtke, T. L., Moser, M. L., Weber, E. P., 3rd, Surgical insertion of transmitters and telemetry methods in fisheries research. Am J Vet Res. 75, 402-416 (2014).
  10. Bastlund, J. F., Jennum, P., Mohapel, P., Vogel, V., Watson, W. P. Measurement of cortical and hippocampal epileptiform activity in freely moving rats by means of implantable radiotelemetry. J Neurosci Methods. 138, 65-72 (2004).
  11. Jeutter, D. C. Biomedical telemetry techniques. Crit Rev Biomed Eng. 7, 121-174 (1982).
  12. Williams, P., et al. The use of radiotelemetry to evaluate electrographic seizures in rats with kainate-induced epilepsy. J Neurosci Methods. 155, 39-48 (2006).
  13. Bertram, E. H., Lothman, E. W. Ambulatory EEG cassette recorders for prolonged electroencephalographic monitoring in animals. Electroencephalogr Clin Neurophysiol. 79, 510-512 (1991).
  14. Bertram, E. H., Williamson, J. M., Cornett, J. F., Spradlin, S., Chen, Z. F. Design and construction of a long-term continuous video-EEG monitoring unit for simultaneous recording of multiple small animals. Brain Res Brain Res Protoc. 2, 85-97 (1997).
  15. Russell, D. M., McCormick, D., Taberner, A. J., Malpas, S. C., Budgett, D. M. A high bandwidth fully implantable mouse telemetry system for chronic ECG measurement. Conf Proc IEEE Eng Med Biol Soc. , 7666-7669 (2011).
  16. Lin, D. C., Bucher, B. P., Davis, H. P., Sprunger, L. K. A low-cost telemetry system suitable for measuring mouse biopotentials. Med Eng Phys. 30, 199-205 (2008).
  17. Aghagolzadeh, M., Zhang, F., Oweiss, K. An implantable VLSI architecture for real time spike sorting in cortically controlled Brain Machine Interfaces. Conf Proc IEEE Eng Med Biol Soc. , 1569-1572 (2010).
  18. Bonfanti, A., et al. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal. Conf Proc IEEE Eng Med Biol Soc. , (2010).
  19. Chang, P., Hashemi, K. S., Walker, M. C. A novel telemetry system for recording EEG in small animals. J Neurosci Methods. 201, 106-115 (2011).
  20. Chen, H. Y., Wu, J. S., Hyland, B., Lu, X. D., Chen, J. J. A low noise remotely controllable wireless telemetry system for single-unit recording in rats navigating in a vertical maze. Med Biol Eng Comput. 46, 833-839 (2008).
  21. De Simoni, M. G., De Luigi, A., Imeri, L., Algeri, S. Miniaturized optoelectronic system for telemetry of in vivo voltammetric signals. J Neurosci Methods. 33, 233-240 (1990).
  22. Farshchi, S., Nuyujukian, P. H., Pesterev, A., Mody, I., Judy, J. W. A TinyOS-enabled MICA2-based wireless neural interface. IEEE Trans Biomed Eng. 53, 1416-1424 (2006).
  23. Gottesmann, C., Rodi, M., Rebelle, J., Maillet, B. Polygraphic recording of the rat using miniaturised telemetry equipment. Physiol Behav. 18, 337-340 (1977).
  24. Gottesmann, C., Rebelle, J., Maillet, B., Rodi, M., Rallo, J. L. Polygraphic recording in the rat by a miniaturized radiotelemetric technic. C R Seances Soc Biol Fil. 169, 1584-1589 (1975).
  25. Handoko, M. L., et al. A refined radio-telemetry technique to monitor right ventricle or pulmonary artery pressures in rats: a useful tool in pulmonary hypertension research. Pflugers Arch. 455, 951-959 (2008).
  26. Hanley, J., Zweizig, J. R., Kado, R. T., Adey, W. R., Rovner, L. D. Combined telephone and radiotelemetry of the EEG. Electroencephalogr Clin Neurophysiol. 26, 323-324 (1969).
  27. Irazoqui, P. P., Mody, I., Judy, J. W. Recording brain activity wirelessly. Inductive powering in miniature implantable neural recording devices. IEEE Eng Med Biol Mag. 24, 48-54 (2005).
  28. Lapray, D., Bergeler, J., Dupont, E., Thews, O., Luhmann, H. J. A novel miniature telemetric system for recording EEG activity in freely moving rats. J Neurosci Methods. 168, 119-126 (2008).
  29. Lee, S. B., Yin, M., Manns, J. R., Ghovanloo, M. A wideband dual-antenna receiver for wireless recording from animals behaving in large arenas. IEEE Trans Biomed Eng. 60, 1993-2004 (2013).
  30. Morrison, T., Nagaraju, M., Winslow, B., Bernard, A., Otis, B. P. A 0.5 cm(3) four-channel 1.1 mW wireless biosignal interface with 20 m range. IEEE Trans Biomed Circuits Syst. 8 (3), 138-147 (2014).
  31. Moscardo, E., Rostello, C. An integrated system for video and telemetric electroencephalographic recording to measure behavioural and physiological parameters. J Pharmacol Toxicol Methods. 62, 64-71 (2010).
  32. Mumford, H., Wetherell, J. R. A simple method for measuring EEG in freely moving guinea pigs. J Neurosci Methods. 107, 125-130 (2001).
  33. Nagasaki, H., Asaki, Y., Iriki, M., Katayama, S. Simple and stable techniques for recording slow-wave sleep. Pflugers Arch. 366, 265-267 (1976).
  34. Podgurniak, P. A simple, PC-dedicated, implanted digital PIM-radiotelemetric system. Part 2: The multichannel system. Biomed Tech (Berl). 46, 273-279 (2001).
  35. Ruedin, P., Bisang, J., Waser, P. G., Borbely, A. A. Sleep telemetry in the rat: I. a miniaturized FM--AM transmitter for EEG and EMG). Electroencephalogr Clin Neurophysiol. 44, 112-114 (1978).
  36. Ruther, P., et al. Compact wireless neural recording system for small animals using silicon-based probe arrays. Conf Proc IEEE Eng Med Biol Soc. , 2284-2287 (2011).
  37. Saito, T., Watanabe, Y., Nemoto, T., Kasuya, E., Sakumoto, R. Radiotelemetry recording of electroencephalogram in piglets during rest. Physiol Behav. 84, 725-731 (2005).
  38. Sumiyoshi, A., Riera, J. J., Ogawa, T., Kawashima, R. A mini-cap for simultaneous EEG and fMRI recording in rodents. Neuroimage. 54, 1951-1965 (2011).
  39. Sundstrom, L. E., Sundstrom, K. E., Mellanby, J. H. A new protocol for the transmission of physiological signals by digital telemetry. J Neurosci Methods. 77, 55-60 (1997).
  40. Wang, M., et al. A telemetery system for neural signal acquiring and processing. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 28, 49-53 (2011).
  41. Cotugno, M., Mandile, P., D'Angiolillo, D., Montagnese, P., Giuditta, A. Implantation of an EEG telemetric transmitter in the rat. Ital J Neurol Sci. 17, 131-134 (1996).
  42. Vogel, V., Sanchez, C., Jennum, P. EEG measurements by means of radiotelemetry after intracerebroventricular (ICV) cannulation in rodents. J Neurosci Methods. 118, 89-96 (2002).
  43. Louis, R. P., Lee, J., Stephenson, R. Design and validation of a computer-based sleep-scoring algorithm. J Neurosci Methods. 133, 71-80 (2004).
  44. Tang, X., Sanford, L. D. Telemetric recording of sleep and home cage activity in mice. Sleep. 25, 691-699 (2002).
  45. Bassett, L., et al. Telemetry video-electroencephalography (EEG) in rats, dogs and non-human primates: methods in follow-up safety pharmacology seizure liability assessments. J Pharmacol Toxicol Methods. 70, 230-240 (2014).
  46. Authier, S., et al. Video-electroencephalography in conscious non human primate using radiotelemetry and computerized analysis: refinement of a safety pharmacology model. J Pharmacol Toxicol Methods. 60, 88-93 (2009).
  47. Yee, B. K., Singer, P. A conceptual and practical guide to the behavioural evaluation of animal models of the symptomatology and therapy of schizophrenia. Cell Tissue Res. 354, 221-246 (2013).
  48. Fahey, J. R., Katoh, H., Malcolm, R., Perez, A. V. The case for genetic monitoring of mice and rats used in biomedical research. Mamm Genome. 24, 89-94 (2013).
  49. Hunsaker, M. R. Comprehensive neurocognitive endophenotyping strategies for mouse models of genetic disorders. Prog Neurobiol. 96, 220-241 (2012).
  50. Majewski-Tiedeken, C. R., Rabin, C. R., Siegel, S. J. Ketamine exposure in adult mice leads to increased cell death in C3H, DBA2 and FVB inbred mouse strains. Drug Alcohol Depend. 92, 217-227 (2008).
  51. Meier, S., Groeben, H., Mitzner, W., Brown, R. H. Genetic variability of induction and emergence times for inhalational anaesthetics. Eur J Anaesthesiol. 25, 113-117 (2008).
  52. Bonthuis, P. J., et al. Of mice and rats: key species variations in the sexual differentiation of brain and behavior. Front Neuroendocrinol. 31, 341-358 (2010).
  53. Buckmaster, P. S., Haney, M. M. Factors affecting outcomes of pilocarpine treatment in a mouse model of temporal lobe epilepsy. Epilepsy Res. , 102-153 (2012).
  54. Jonasson, Z. Meta-analysis of sex differences in rodent models of learning and memory: a review of behavioral and biological data. Neurosci Biobehav Rev. 28, 811-825 (2005).
  55. Richardson, C. A., Flecknell, P. A. Anaesthesia and post-operative analgesia following experimental surgery in laboratory rodents: are we making progress. Altern Lab Anim. 33, 119-127 (2005).
  56. Liles, J. H., Flecknell, P. A., Roughan, J., Cruz-Madorran, I. Influence of oral buprenorphine, oral naltrexone or morphine on the effects of laparotomy in the rat. Lab Anim. 32, 149-161 (1998).
  57. Liles, J. H., Flecknell, P. A. The effects of buprenorphine, nalbuphine and butorphanol alone or following halothane anaesthesia on food and water consumption and locomotor movement in rats. Lab Anim. 26, 180-189 (1992).
  58. Flecknell, P. A. Anaesthesia of animals for biomedical research. Br J Anaesth. 71, 885-894 (1993).
  59. Davis, J. A. Mouse and rat anesthesia and analgesia. Curr Protoc Neurosci. , (2008).
  60. Gargiulo, S., et al. Mice anesthesia, analgesia, and care, Part I: anesthetic considerations in preclinical research. ILAR J. 53, 55-69 (2012).
  61. Weiergraber, M., Henry, M., Hescheler, J., Smyth, N., Schneider, T. Electrocorticographic and deep intracerebral EEG recording in mice using a telemetry system. Brain Res Brain Res Protoc. 14, 154-164 (2005).
  62. Lundt, A., et al. EEG radiotelemetry in small laboratory rodents: a powerful state-of-the art approach in neuropsychiatric, neurodegenerative, and epilepsy research. Neural Plast. , (2016).

This article has been published