Aby wyświetlić tę treść, wymagana jest subskrypcja JoVE. Zaloguj się lub rozpocznij bezpłatny okres próbny.
Untargeted metabolomics provides a hypothesis generating snapshot of a metabolic profile. This protocol will demonstrate the extraction and analysis of metabolites from cells, serum, or tissue. A range of metabolites are surveyed using liquid-liquid phase extraction, microflow ultraperformance liquid chromatography/high-resolution mass spectrometry (UPLC-HRMS) coupled to differential analysis software.
Here we present a workflow to analyze the metabolic profiles for biological samples of interest including; cells, serum, or tissue. The sample is first separated into polar and non-polar fractions by a liquid-liquid phase extraction, and partially purified to facilitate downstream analysis. Both aqueous (polar metabolites) and organic (non-polar metabolites) phases of the initial extraction are processed to survey a broad range of metabolites. Metabolites are separated by different liquid chromatography methods based upon their partition properties. In this method, we present microflow ultra-performance (UP)LC methods, but the protocol is scalable to higher flows and lower pressures. Introduction into the mass spectrometer can be through either general or compound optimized source conditions. Detection of a broad range of ions is carried out in full scan mode in both positive and negative mode over a broad m/z range using high resolution on a recently calibrated instrument. Label-free differential analysis is carried out on bioinformatics platforms. Applications of this approach include metabolic pathway screening, biomarker discovery, and drug development.
Due to recent technological advances in the field of HRMS, untargeted, hypothesis-generating metabolomics approaches have become a feasible approach to analysis of complex samples.1 Mass spectrometers capable of 100,000 resolution facilitating routine low part per million (ppm) mass accuracy have become widely available from multiple vendors.2,3 This mass accuracy allows greater specificity and confidence in a preliminary assignment of analyte identity, isotopic pattern recognition, and adduct identification.4 When coupled with an appropriate extraction procedure and high-performance LC or UPLC, complex mixtures can be analyzed with additional specificity derived from retention time data.5 UPLC possesses greater chromatographic efficiency and allows greater sensitivity, resolution and analysis time making a greater coverage of the metabolome possible.6 The resulting large datasets can be integrated into any of multiple differential analysis software and mined for useful patterns or individual analytes of interest.7,8,9,10,11 Putative hits can be initially identified using a combination of peak detection algorithms, accurate mass based chemical formula prediction, fragmentation prediction, and chemical database searching. This approach allows prioritization of targets for time-consuming complete structural identification or for development of more sensitive and more specific stable isotope dilution UPLC/selected or multiple reaction monitoring/MS studies that are the current gold standard methods for quantification.12
The varying nature of biological samples has led to optimization of extraction protocols for urine13, cells14, serum15, or tissue16. This protocol features extractions for cells, serum, and tissue. Where appropriate, comments and additional references have been included for modifications of the procedure to address inclusion of stable isotopes, or for inclusion of especially unstable metabolites.
1. Sample Extraction from Cells
2. Sample Extraction from Serum
3. Sample Extraction from Tissue
4. Re-suspension and Filtration of Samples for UPLC
5. UPLC Setup
6. Mass Spectrometer Setup
7. Differential Analysis
The results presented show selected data from a 6-hr treatment of SH-SY5Y glioblastoma cells with the pesticide and mitochondrial complex I inhibitor rotenone. For brevity, only the organic phase positive mode data is presented. The samples were processed and analyzed as described above (Figure 1, Table 1, Table 2) and loaded onto two differential analysis platforms for label-free quantification, SIEVE and XCMS online. Although a large number of hits (Figure 2, Figure 3)...
Untargeted metabolomics offers a powerful tool for investigating endogenous or xenobiotic biotransformations, or capturing a metabolic profile from a sample of interest. The output of the technique scales with the resolution and sensitivity of the technology used to separate and analyze the sample, the ability to deal with the large datasets generated, and the ability to mine the dataset for useful information (e.g. accurate mass database searching). Recently, this has been facilitated by advances in high resolu...
Authors have nothing to disclose.
We acknowledge support of NIH grants P30ES013508 and 5T32GM008076. We also thank Thermo Scientific for access to SIEVE 2.0 and Drs. Eugene Ciccimaro and Mark Sanders of Thermo Scientific for useful discussions.
Name | Company | Catalog Number | Comments |
Reagent | |||
Phosphate Buffered Saline | Mediatech | 21-031-CM | |
Water (H2O) | Fisher Scientific | W7-4 | (optima) |
Acetonitrile (CH3CN) | Fisher Scientific | A996-4 | (optima) |
Methanol (CH3OH) | Fisher Scientific | A454-4 | (optima) |
Isopropanol | Fisher Scientific | A464-4 | (optima) |
Chloroform (CH3Cl) | Sigma-Aldrich | 366927 | Hazard |
Dichloromethane (CH2Cl2) | Acros Organics | 61030-1000 | To replace chloroform |
Diethyl Ether | Sigma-Aldrich | 346136 | To replace chloroform |
Formic Acid (FA) | Fisher Scientific | (optima) | |
NH4OH | Fisher Scientific | A470-250 | (optima) |
Ammonium formate (HCOONH4) | Sigma-Aldrich | 78314 | |
MicroSpin C18 Columns | Nest Group Inc | SS18V | |
Pasteur Pipettes | Fisher Scientific | 13-678-200 | |
10 ml Glass Centrifuge Tubes | Kimble Chase | 73785-10 | |
10 ml Plastic Centrifuge Tubes | CellTreat | CLS-4301-015 | |
LC Vials (glass) | Waters | 60000751CV | |
LC Inserts (glass) | Waters | WAT094171 | |
LC Vials (plastic) | Waters | 186002640 | |
0.22 μm Filters | Corning | 8169 | nylon |
2 ml Eppendorf Tubes | BioExpress | C-3229-1 | Low Retention |
Equipment | |||
High Resolution Mass Spectrometer | Thermo Scientific | LTQ XL-Orbitrap | |
HPLC/UPLC | Waters | nanoACQUITY UPLC | |
Source | Michrom | Thermo Advance Source | |
Differential Analysis Software | Thermo Scientific | SIEVE 2.0 | |
nanoACQUITY C18 BEH130 | Waters | 186003546 | 1.7 μm particle size, 150 mm x 100 μm |
Acentis Express C8 | Sigma-Aldrich | 54262 | 2.7 μm particle size, 15 cm x 200 μm |
Zapytaj o uprawnienia na użycie tekstu lub obrazów z tego artykułu JoVE
Zapytaj o uprawnieniaThis article has been published
Video Coming Soon
Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone