Podsumowanie

Here a novel region of interest analysis protocol based on sorting best-fit ellipses assigned to regions of positive signal within two-dimensional time lapse image sequences is demonstrated. This algorithm may enable investigators to comprehensively analyze physiological Ca2+ signals with minimal user input and bias.

Streszczenie

Intracellular Ca2+ signals are commonly studied with fluorescent Ca2+ indicator dyes and microscopy techniques. However, quantitative analysis of Ca2+ imaging data is time consuming and subject to bias. Automated signal analysis algorithms based on region of interest (ROI) detection have been implemented for one-dimensional line scan measurements, but there is no current algorithm which integrates optimized identification and analysis of ROIs in two-dimensional image sequences. Here an algorithm for rapid acquisition and analysis of ROIs in image sequences is described. It utilizes ellipses fit to noise filtered signals in order to determine optimal ROI placement, and computes Ca2+ signal parameters of amplitude, duration and spatial spread. This algorithm was implemented as a freely available plugin for ImageJ (NIH) software. Together with analysis scripts written for the open source statistical processing software R, this approach provides a high-capacity pipeline for performing quick statistical analysis of experimental output. The authors suggest that use of this analysis protocol will lead to a more complete and unbiased characterization of physiologic Ca2+ signaling.

Wprowadzenie

Ca2+ is a ubiquitous second messenger signaling molecule and cytosolic Ca2+ levels are highly regulated. Intracellular Ca2+ signals are complex and include isolated transients, oscillations, and propagating waves1-4. Spatial and temporal control of Ca2+ is thought to underlie physiological signal specificity, and therefore the analysis of Ca2+ signal patterns is of considerable interest to investigators in multiple fields5.

Ca2+ indicator dyes such as Fluo-4 and Fura-2 are commonly employed to measure intracellular Ca2+ signals with fluorescence microscopy5-12. Typically, temporal Ca2+ signals are evaluated as time-dependent changes in mean fluorescence within a user-defined area, or region of interest (ROI)5,6,13-16. Currently, manual ROI analysis is both time consuming and labor intensive because it requires users to identify many ROIs and perform repetitive computations17-19. These techniques may also be subject to considerable user error, including introduction of artificial signal modes and exclusion of low amplitude or diffuse signals18,20.

Automated ROI detection algorithms have previously been implemented using a variety of statistical approaches to determine optimal ROI placement, but they have generally been limited to analysis of line scan or pseudo-line scan images, which restricts analysis to a single spatial dimension in time17,19-22. Additionally, many existing algorithms are not adequate to encompass the diversity of Ca2+ release events which range from periodic, localized transients to propagating waves23,24. Comprehensive evaluation of physiological Ca2+ signals is often further complicated by the presence of significant image artifact that confounds signal to noise discrimination in many experimental systems.

Previously, an automated ROI detection algorithm solution to Ca2+ signal transient detection, implemented as a plugin for NIH ImageJ software (National Institutes of Health, Bethesda, MD), was developed and validated25,26. This algorithm, called LC_Pro, was designed to identify and analyze ROIs encompassing Ca2+ signal transients in two-dimensional time lapse image sequences. Here a practical experimental protocol and representative demonstration of an application of the algorithm in porcine coronary artery endothelium is provided, with additional postprocessing using the open source statistical processing software R to generate usable graphical output.

Protokół

1. Vessel Dissection and Imaging

  1. Harvest tissue from domestic juvenile pigs as described in Martens et al27. Place harvested swine right ventricles into a polydimethylsiloxane (PDMS) bottom dissection dish containing HEPES buffered physiological saline solution (PSS).
    1. With the aid of a stereomicroscope, dissect and remove a segment of the left anterior descending coronary artery (~8 mm length, 0.5 mm diameter) from surrounding tissue using forceps and spring scissors by removing the vessel segment from the surrounding cardiac tissue layers. NOTE: Take care to not puncture the vessel wall.
    2. Place a PDMS block (1 x 0.5 x 0.5 cm) into the dissection dish, and use a needle to pin it to the bottom. Cut an approximately 40 μm diameter tungsten wire into twelve ~0.3 cm length segments, forming micropins, and place these in the dish. Using forceps, secure one end of the vessel segment to the block with a micropin.
    3. Carefully insert small spring scissors into the vessel lumen, and cut longitudinally down one side of the vessel to open it completely. Orient the opened vessel segment with the endothelium up.
    4. Use the remaining micropins to secure the borders of the opened vessel segment to block such that the vessel forms a flat rectangle. NOTE: Micropin tops should be bent to 90° and inserted until flush with the block surface. Care should be taken to stretch the vessel preparation without overstretching; final width should be ~1.5x the starting unstretched width.
    5. Prepare a small volume (~1 ml) of Fluo-4 AM loading solution by mixing Fluo-4 AM (10 µM) dissolved in DMSO with pluronic (0.03 %) in a HEPES buffered PSS (containing in mM: 134 NaCl, 6 KCl, 1 MgCl, 10 HEPES, 10 glucose), and insert the entire block into the loading solution for approximately 40 min at room temperature in the dark.
    6. After loading, wash the block in HEPES buffered PSS for 5-10 min.
    7. Mount the block onto 50-100 µm thick spacers in a coverglass bottom chamber containing HEPES buffered PSS. NOTE: Metal pins can be used as spacers and ensure the vessel segment is facing down and not touching the spacers.
    8. Place the chamber on the stage of an inverted microscope equipped for confocal imaging, and focus on the endothelial cell layer.
    9. Capture time lapse image sequences of basal relative fluorescence for ~3 min at 20X magnification and a frame rate of ~8 frames per sec using confocal image sequence aquisition software.
    10. After ~ 3 min of recording basal fluorescence, replace HEPES buffered PSS solution with the same volume (~1 ml) of Substance P (100 pM) dissolved in HEPES buffered PSS, and record for an addtional 3 min.

2. Automated Analysis

  1. Render image sequence(s) of fluorescent calcium activity from confocal acquisition software as 8 bit, grayscale '.tif' format files with no scale information.
  2. Open ImageJ, click 'open' in the file menu, and select the appropriate image sequence in the explorer window to view the image sequence(s) in ImageJ.
  3. Determine an appropriate ROI diameter by using the rectangular ROI tool to estimate the upper and lower boundaries of the spatial spread of activity within the image sequence(s). NOTE: The mean rectangular diameter is a suitable choice for ROI diameter.
  4. Create a new folder on the computer hard drive, and add the image sequence(s) into the folder directory.
  5. In ImageJ, click the 'plugins' window, then click 'LC_Pro' to start the analysis.
  6. Enter the ROI diameter value and select the filter threshold value (either 0.05 or 0.01).
  7. Click the 'drug treatment' checkbox and enter the time point values immediately before and after the drug was added (in seconds).
  8. Click 'ok', and enter the image sequence directory into the file explorer window.

3. Graphical Output

  1. Download R version 3.0.2 from http://www.r-project.org/.
  2. Open the 32 bit version of R.
  3. Click “file”, then 'open script' and select the 'traceplot.R' R script for generating graphical experimental reports.
  4. Install the calibrate, and gplots packages by selecting 'packages', 'install packages', and selecting the appropirate packages.
  5. Click 'file', then 'change directory' command, and use the explorer window to select the directory that corresponds to the LC_Pro analysis output.
  6. Click on the script window and then the 'run all' command to run the script.

Wyniki

A custom algorithm, LC_Pro, was developed and implemented in order to perform automated analysis of Ca2+ dynamics on confocal image sequences. As depicted in Figure 1, the algorithm utilizes sequential processing modules that A) detect and track sites of dynamic Ca2+ change above statistical (p < 0.01) noise, B) define regions of interest (ROI) automatically at active site centers, and C) calculate average fluorescence intensities at ROIs to determine specific event parameters. ...

Dyskusje

Decoding complex Ca2+ signals at the cellular and multicellular level will require rigorous experimental and analytical approaches. Here, an approach is described in which time resolved confocal image sequences of Ca2+ dependent fluorescence are subjected to an automated analysis that identifies and quantifies statistically relevant Ca2+ signals within intact cellular fields In the specific case presented, an artery segment was isolated from pig heart, pinned opened to expose the endothel...

Ujawnienia

The authors have nothing to disclose.

Podziękowania

This work was supported in part by National Institutes of Health Grants HL-085887, HL-092992, S10RR027535, and MOP-93676.

Materiały

NameCompanyCatalog NumberComments
Dissection dishFisher Sci#08-772-70
Polydimethylsiloxane (PDMS)Fisher Sci#NC9644388elastomer kit, must be molded into dishes
HEPES-buffered PSSSigma#H3375-250GHEPES acid
StereomicroscopeNikon Inst.#MNA42000
ForcepsFine Science Tools#11223-20
Spring scissorsFine Science Tools15003-08
Tungsten wireScientific Inst Svcs#406
Fluo-4 AMLife Tech.#F-14201
Pluronic F-127Life Tech.#P3000MP
Metal pinsFine Science Tools#26002-10
Cover-glass bottom chamberCustom designed
Spinning disc confocal microscopePerkin ElmerRS-3
ImageJ softwaredownload at: http://rsbweb.nih.gov/ij/download.html
LC_Pro plugin for imageJdownload at: http://rsbweb.nih.gov/ij/plugins/lc-pro/index.html
R softwaredownload at: http://www.r-project.org/
R traceplot scriptdownload at: https://docs.google.com/file/d/0B-PSp1D9e2fjV3NIcGppUzkxdEk/edit?usp=sharing

Odniesienia

  1. Berridge, M. J. Inositol trisphosphate and calcium signalling. Nature. 361 (6410), 315-325 (1993).
  2. Berridge, M. J., et al. The versatility and universality of calcium signalling. Nat Rev Mol Cell Biol. 1 (1), 11-21 (2000).
  3. Delisle, S. The four dimensions of calcium signalling in Xenopus oocytes. Cell Calcium. 12 (2-3), 217-227 (1991).
  4. Dupont, G., et al. Calcium dynamics: spatio-temporal organization from the subcellular to the organ level. Int Rev Cytol. 261, 193-245 (2007).
  5. Hayashi, H., Miyata, H. Fluorescence imaging of intracellular Ca2. J Pharmacol Toxicol Methods. 31 (1), 1-10 (1994).
  6. Barreto-Chang, O. L., Dolmetsch, R. E. Calcium imaging of cortical neurons using Fura-2 AM. J Vis Exp. 23, (2009).
  7. Hong, J. H., et al. Intracellular calcium spikes in rat suprachiasmatic nucleus neurons induced by BAPTA-based calcium dyes. PloS One. 5 (3), (2010).
  8. Kuga, N., et al. Large-scale calcium waves traveling through astrocytic networks in vivo. J Neurosci. 31 (7), 2607-2614 (2011).
  9. Mumtaz, S., et al. The mechanism of agonist induced Ca2+ signalling in intact endothelial cells studied confocally in in situ arteries. Cell Calcium. 49 (1), 66-77 (2011).
  10. Paredes, R. M., et al. Chemical calcium indicators. Methods. 46 (3), 143-151 (2008).
  11. Silei, V., et al. Measurement of intracellular calcium levels by the fluorescent Ca2+ indicator Calcium-Green. Brain Res Brain Res Protoc. 5 (2), 132-134 (2000).
  12. Simpson, A. M. Fluorescent measurement of [Ca2+]c: basic practical considerations. Methods Mol Biol. 937, 3-36 (2006).
  13. Gaspers, L. D., Thomas, A. P. Calcium signaling in liver. Cell Calcium. (3-4), 329-342 (2005).
  14. Hellman, B., et al. Cytoplasmic Ca2+ oscillations in pancreatic ß-cells. Biochem Biophys Acta. 1113 (3-4), 295-305 (1992).
  15. Kansui, Y., et al. Enhanced spontaneous Ca2+ events in endothelial cells reflect signalling through myoendothelial gap junctions in pressurized mesenteric arteries. Cell Calcium. 44 (2), 135-146 (2008).
  16. Tatsumi, H., et al. Measurement of the intracellular calcium concentration in guinea-pig myenteric neurons by using fura-2. Brain res. 451 (1-2), 371-375 (1988).
  17. Lorenz, J. J., et al. Pixel-based criteria-oriented analysis of time-lapse Ca2+-fluorescence images. J Neurosci Meth. 127 (2), 157-166 (2003).
  18. Mukamel, E. A., et al. Automated analysis of cellular signals from large-scale calcium imaging data. Neuron. 63 (6), 747-760 (2009).
  19. Reidl, J., et al. Independent component analysis of high-resolution imaging data identifies distinct functional domains. Neuroimage. 34 (1), 94-108 (2007).
  20. Wegner, F., et al. Automated detection of elementary calcium release events using the á trous wavelet transform. Biophys J. 90 (6), 2151-2163 (2006).
  21. Cheng, H., et al. Amplitude distribution of calcium sparks in confocal images: theory and studies with an automatic detection method. Biophys J. 76 (2), 606-617 (1999).
  22. Picht, E., et al. SparkMaster: automated calcium spark analysis with ImageJ. Am J Physiol Cell Physiol. 293 (3), (2007).
  23. Abramoff, M. D., et al. Image processing with ImageJ. Biophoton Int. 11, 36-42 (2004).
  24. Francis, M., et al. Automated region of interest analysis of dynamic Ca2+ signals in image sequences. Am J Physiol Cell Physiol. 303 (3), (2012).
  25. Qian, X., et al. Recruitment of dynamic endothelial Ca2+ signals by the TRPA1 channel activator AITC in rat cerebral arteries. Microcirculation. 20 (2), 138-148 (2013).
  26. Taylor, M. S., et al. Dynamic Ca2+ signal modalities in the vascular endothelium. Microcirculation. 19 (5), 423-429 (2012).
  27. Martens, C. J., et al. Mucous solids and liquid secretion by airways: studies with normal pig, cystic fibrosis human, and non-cystic fibrosis human bronchi. Am J Physiol Lung Cell Mol Physiol. 301 (2), (2011).

Przedruki i uprawnienia

Zapytaj o uprawnienia na użycie tekstu lub obrazów z tego artykułu JoVE

Zapytaj o uprawnienia

Przeglądaj więcej artyków

Based On The Given TextThe Key Keywords Are Automated AnalysisDynamic Ca2 SignalsImage SequencesIntracellular Ca2 SignalsFluorescent Ca2 Indicator DyesMicroscopy TechniquesRegion Of Interest ROI DetectionOne dimensional Line ScanTwo dimensional Image SequencesEllipsesNoise FilteringCa2 Signal ParametersAmplitudeDurationSpatial SpreadImageJRStatistical Analysis

This article has been published

Video Coming Soon

JoVE Logo

Prywatność

Warunki Korzystania

Zasady

Badania

Edukacja

O JoVE

Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone