Summary

A protocol is presented using synthetic biology techniques to synthesize a set of bacterial biosensors for the analysis of gunshot residue, and to test the functioning of the devices for their intended use using fluorescence spectroscopy.

Abstract

MicRoboCop is a biosensor that has been designed for a unique application in forensic chemistry. MicRoboCop is a system made up of three devices that, when used together, can indicate the presence of gunshot residue (GSR) by producing a fluorescence signal in the presence of three key analytes (antimony, lead, and organic components of GSR). The protocol describes the synthesis of the biosensors using Escherichia coli (E. coli), and the analytical chemistry methods used to evaluate the selectivity and sensitivity of the sensors. The functioning of the system is demonstrated by using GSR collected from the inside of a spent cartridge casing. Once prepared, the biosensors can be stored until needed and can be used as a test for these key analytes. A positive response from all three analytes provides a presumptive positive test for GSR, while each individual device has applications for detecting the analytes in other samples (e.g., a detector for lead contamination in drinking water). The main limitation of the system is the time required for a positive signal; future work may involve studying different organisms to optimize the response time.

Introduction

A biosensor is any analytical device that uses biological components (such as proteins, nucleic acids, or whole organisms) that produce a response that can be used for the detection of a chemical substance or analyte. As an example, the coal mining industry used a biosensor for much of the 20th century to detect the presence of toxic mine gases: the canary in the coal mine1. The biological organism's (canary's) response (death or distress) to a chemical analyte (carbon monoxide) was observed by the miners in order to protect the workers. In a more modern and sophisticated example, bacteria can be altered using synthetic biology techniques to respond to the presence of a certain chemical analyte by exhibiting a specific response, such as the expression of a fluorescent protein.

Synthetic biology is a broad term that refers to the construction of biological devices and systems that do not exist naturally, or the re-design of existing biological systems for a specific purpose2. Synthetic biology is distinguished from genetic engineering by a standard methodology and the existence of standardized parts (standard synthetic biology genetic elements) that can be used to synthesize devices and systems. A part is introduced into the genome of a device, an organism such as a bacterium, to express a certain trait that will serve as an indication of function. For example, in many synthetic devices, the expression of a fluorescent protein is introduced into a single celled organism as a reporter protein. Multiple devices can be combined into a system. The genomes of microorganisms such as bacteria are easy to manipulate in this manner. Numerous examples of biosensors specific to a wide range of chemical analytes have been reported in the literature over the last decade3,4.

In this work, the MicRoboCop system is presented as an example of a biosensor designed using synthetic biology techniques with novel applications in forensic and environmental chemistry. MicRoboCop is a system of three separate devices that, when combined, will allow Escherichia coli to express red fluorescent protein (RFP) in the presence of gunshot residue (GSR) that has been collected from a person’s hands or a surface. Each of the three devices responds to a specific chemical analyte that is known to be a component of GSR5. The three analytes to which the system responds are I. 2,4,6-trinitrotoluene (TNT) and related compounds, II. lead (in the form of lead ions), and III. antimony (also in the form of ions).

GSR consists of many different chemical substances, but the three usually used to identify a residue as GSR are barium, lead, and antimony5. The standard evidentiary test for the identification of GSR is to use scanning electron microscopy (SEM) with energy dispersive X-ray fluorescence (EDX)5. SEM-EDX allows analysts to identify the unique morphology and the elemental components of GSR. Presently, there are few widely used binary presumptive tests available. One recently published presumptive test uses ion-mobility spectroscopy (IMS), which is specialized equipment that might not be available in many labs6. There are also a few color “spot” tests that can be used, though they are typically used for distance determination or for GSR identification on bullet holes and wounds5. Additionally, there has been some limited attention in the literature to electrochemical tests for GSR that employ voltammetric analysis, which has the advantage of potentially being field portable, or anodic stripping voltammetry, which is an extremely sensitive method for metallic elements7. There is very little mention in the literature of biosensors designed specifically for the purpose of detecting GSR, though some biosensors for other forensic applications have been published8.

The biological elements for each device in the MicRoboCop system, and the plasmid construction, are illustrated in Figure 1. The curved arrow in Figure 1b represents the promoter region that is activated in the presence of the analyte, the oval is the ribosomal binding site that allows translation of the reporter protein, the gray box labeled RFP is the gene that expresses red fluorescent protein, and the red octagon is the transcription termination site. All three devices will be used together as a system to detect GSR. Each device with a specific promoter (SbRFP, PbRFP, and TNT-RFP) will be incubated with the sample that is being tested and fluorescence of RFP will be measured. RFP will only be expressed if the appropriate chemical analyte is present and activates the promoter region. Three devices that respond to some of the chemical substances present in GSR have been designed and are presented in this work.

The promoters used in the three MicRoboCop devices are an arsenic and antimony sensitive promoter, SbRFP9,10, a lead sensitive promoter, PbRFP11,12 and a TNT sensitive promoter, TNT-RFP13. Because a search in the literature revealed no promoter designed to respond to barium, the TNT promoter was selected instead since this promoter is sensitive to a number of structurally related compounds (in particular, 2,4-dinitrotoluene and dinitrobenzene) that are known to be a part of the organic compounds left behind in GSR. This promoter has successfully been used to specifically detect minute quantities of TNT and 2,4-dinitrotoluene (2,4-DNT) in buried land mines13. Using the three devices together as a system, a positive test for GSR will produce fluorescence in all three devices. A fluorescence signal in only one or two devices will indicate another environmental source of the analyte(s) or in the case of the TNT promoter, activation by a compound that is not an organic compound left behind in GSR. By using all three devices together, the possibility of a false positive results due to environmental sources is minimized. Lead-free ammunition, which is gaining in popularity, still represents only about 5% of ammunition sales in the United States; hence, false negative results due to the absence of lead may be a possibility but there is still utility in a sensor that uses lead as a marker for GSR14. In addition to this specific forensic application, each device can be used separately for purposes of detecting environmental contaminants.

The protocols presented include the synthetic biology techniques used to create the devices (sensor bacteria) and the analytical techniques to check the function of the devices and analyze the fluorescence signals obtained. The protocol also includes collection of forensic evidence in the form of hand wiping to collect GSR from the hands of a suspect or swabbing to collect GSR from a surface. Results from the lead sensor device are presented as example results, along with a demonstration of a positive test for GSR using a spent cartridge casing.

Access restricted. Please log in or start a trial to view this content.

Protocol

NOTE: Synthesis of E. coli expressing RFP is presented.

1. Preparation of plasmid DNA from E. coli

  1. Thaw E.coli containing a plasmid with an RFP gene and ampicillin resistance gene and grow the E.coli on Luria Broth (LB) agar plates containing 100 µg/mL ampicillin at 37 °C for 24 h. For example, use the J10060 plasmid from the registry of standard biological parts used for synthetic biology (see Table of Materials). The J10060 plasmid includes a gene for RFP (red fluorescent protein) under the control of a pBad promoter region and an ampicillin resistance gene. Alternatively, transform E.coli (refer to step 3.2) with the plasmid prior to growth on the LB agar plates.
  2. Follow a standard miniprep protocol (see Table of Materials) to isolate DNA from 1 mL of an E. coli culture that contains the J10060 plasmid. The purpose of the following protocol is to remove the pBad promoter and replace it with the desired promoter for the device.
  3. Following the plasmid miniprep, store DNA in the freezer until ready for digestion.

2. Restriction enzyme digestion

  1. Set up the following reaction in a microcentrifuge tube for EcoRI and NheI digestion: 10 μL of J10060 plasmid DNA (isolated in step 1), 8 μL of water, and 1 μL each of EcoRI and NheI enzymes pre-mixed with 1 μL of buffer (see Table of Materials).
  2. For the promoter DNA, set up the following reaction in a microcentrifuge tube for EcoRI and NheI digestion: 10 μL of annealed promoter DNA sequences (8 μL of water, and 1 μL each of EcoRI and NheI enzymes pre-mixed with 1 μL of buffer.
    1. For Sb-, Pb-, or TNT-RFP (see Table of Materials), dissolve the oligonucleotides in buffer (30 mM HEPES, pH 7.5; 100 mM potassium acetate), incubate in equal molar concentrations, heat to 94 °C for 2 min, and gradually cool at room temperature).
  3. Mix the samples by pipetting gently up and down with the pipette set to 10 μL.
  4. Incubate for 30 min at 37 °C.
  5. Heat inactivate the enzymes at 80 °C for 5 min.
  6. Store the digested DNA in the freezer until ready for the next step.

3. Ligation and transformation

  1. Ligation
    1. Using the plasmid and promoter DNA that were double digested with EcoRI and NheI in step 2, set up the reaction mixture shown in Table 1 in a microcentrifuge tube on ice; add the T4 DNA Ligase last.
      NOTE: Table 1 shows a ligation using a molar ratio of 1:3 vector to insert for the indicated DNA sizes.
    2. Gently mix the reaction by pipetting up and down and microcentrifuge briefly.
    3. Incubate at room temperature for 10 min.
    4. Heat inactivate at 65 °C for 10 min.
  2. Transformation
    1. Thaw a tube with 20 µL of DH5-alpha Competent E. coli cells on ice until the last ice crystals disappear.
    2. Add 5 µL of plasmid DNA to the cell mixture. Carefully flick the tube 4-5 times to mix the cells and DNA.
    3. Place the mixture on ice for 2 min.
    4. Heat shock at exactly 42 °C for exactly 30 s. Do not mix.
    5. Place on ice for 2 min. Do not mix.
    6. Pipette 380 µL of room temperature SOC into the mixture. Immediately spread onto an LB agar plate containing ampicillin (100 µg/mL) and incubate overnight at 37 °C.
    7. Check the plates within 24 h for growth.
    8. Seal the plates with sealing film and store in the refrigerator until ready for next step.

4. Colony PCR

  1. Add to a PCR tube (set up 4 reaction tubes) the reaction mixtures shown in Table 2.
  2. Gently mix the reactions by pipetting up and down.
  3. Using a yellow pipette tip, scrape a colony (or very small region) of the transformed E. coli. Transfer a swipe of this E. coli onto a new LB/ampicillin/agar plate that has been sectioned off, and then insert the pipette tip into the PCR tube. Shake the pipette tip to mix the E. coli with the PCR mix. Repeat three more times for additional colonies. Transfer the PCR tubes to a PCR machine and begin thermocycling using the program shown in Table 3.
  4. Run gel electrophoresis using a 2% agarose gel in TAE to determine which colonies have the best ligation into the plasmid and grow those colonies on a new plate.
  5. Store the plates in the refrigerator until ready for testing. Prepare a liquid culture in Luria broth with 100 µg/mL ampicillin added for chemical testing.

5. DNA Sequencing

  1. For each sample, add 5 µL of plasmid, 4 µL of the sequencing primer, and 3 µL of deionized water.
  2. Place this mixture into a tube and send it for DNA sequencing (see Table of Materials).
  3. Analyze DNA sequence data to compare the expected and observed DNA sequences using DNA sequence analysis software to ensure that there is no mutation and that the genes were correctly inserted.
    NOTE: Using E. coli as a chemical sensor is presented below.

6. Preparation of E. coli cultures

  1. Prepare LB with 100 µg/mL ampicillin for liquid cultures.
  2. Prepare liquid cultures of the sensor bacteria, the positive control* bacteria and the negative control** bacteria.
    NOTE: *Positive control bacteria: E. coli containing a plasmid with the RFP gene under control of a constitutive promoter; plasmid E1010 from the registry of standard biological parts used for synthetic biology (see Table of Materials) was used in this work.
    **Negative control bacteria: E. coli containing a plasmid with the RFP gene under control of a different promoter, such as the pBad promoter (plasmid J10060 from the registry of standard biological parts used for synthetic biology (see Table of Materials)) or a plasmid that does not have the RFP gene.
  3. Place the cultures into a shaking incubator at 37 °C and 220 rpm for a minimum of 8 h, maximum of 18 h. Cloudy broth indicates bacterial growth.

7. Titrating E. coli to check function of device

NOTE: Once the sensors have been titrated to check function, this step does not need to be repeated. A positive control in the form of addition of lead, antimony, and 2,4-DNT or 1,3-dinitrobenzene (1,3-DNB) can check the function of the devices for each use without the need for the full titration.

  1. Prepare a stock solution of the analyte(s) of interest at a concentration of 10 ppm in water. If solubility is an issue, use a 50/50 water/methanol mixture.
  2. Using Table 4 as a guide, label the appropriate number of sterile culture tubes and place 2 mL of the cultured broth (from protocol step 6) into each tube.
    NOTE: In order to determine a general analytical range, do at least three different levels of an analyte with the sensor bacteria, one level with the negative control, and one level with the positive control. There should also be one tube of each of the bacteria that has no added metal (another type of negative control). To more accurately determine analytical range and limits of detection, use a larger range of analyte concentrations.
  3. Add analyte stock solution to the tubes containing 2 mL of broth as noted in Table 4, place the snap caps on the culture tube so that they are loose (to allow air flow into the tube), and vortex the culture tube.
  4. Leaving the snap caps loosely on the culture tubes, place into a shaking incubator at 220 rpm and 37 °C for at least 24 h.
  5. Remove the tubes from the incubator, snap the caps onto the tubes tightly, and store the tubes in the refrigerator until ready for fluorescence analysis.

8. Using E. coli as chemical sensor for GSR

  1. Using an ethanol-based wipe designed for removing lead (see Table of Materials), wipe all surfaces of the hands, including between the fingers. Use a separate wipe for each hand. Store the wipes in an appropriately labelled sealable baggie until analysis.
  2. For surfaces to be tested: use an alcohol-based wipe for large surfaces or a cotton swab moistened with ethanol for small surfaces.
    NOTE: To demonstrate the sensors’ response to GSR, the inside of a spent .40 caliber cartridge casing was swabbed with an ethanol moistened cotton swab.
  3. Wearing clean gloves and using scissors that have been cleaned with alcohol, cut an approximately 1 cm2 section out of the center of the wipe.
  4. Place the cut piece of the hand wipe or the cotton swab directly into a culture tube that contains 2 mL of the sensor bacteria, ensuring that it is submerged in the broth.
  5. Proceed as described above in steps 7.4 – 7.5.

9. Fluorescence analysis using portable spectrometer (see Table of Materials)

  1. Use a vortex mixer to shake the tubes.
  2. Prepare the spectrometer to collect fluorescence emission at the appropriate wavelength for your RFP variant with an excitation wavelength of 500 nm.
  3. Use the Luria broth to record a blank spectrum.
  4. Carefully transfer each supernatant to a low volume cuvette and collect the emission intensity.

10. Fluorescence analysis using 96-well plate reader (see Table of Materials)

  1. Use a vortex mixer to shake the tubes.
  2. Transfer 200 mL of the broth to a well in the well plate. Record which samples went into each well of the plate.
  3. Set up the fluorimeter to collect the emission intensity at the appropriate wavelength for the RFP variant.

11. Data analysis

  1. Using the signal obtained from all negative controls (RFP negative bacteria or sensor bacteria with no analyte added), calculate an average fluorescence signal for the background.
  2. Subtract the average background signal from each fluorescence signal obtained for the sensor bacteria to get a background corrected fluorescence intensity.
  3. Estimate the signal-to-noise (S/N) ratio by dividing the background corrected fluorescence intensity by the average background signal. If the S/N ratio is greater than 3, the test is positive.

Access restricted. Please log in or start a trial to view this content.

Results

Fluorescence spectra for the RFP variant used in this work are shown in Figure 2. These data are from the PbRFP device as it responds to lead and the TNT-RFP device as it responds to two analytes, 2,4-DNT and 1,3-DNB. This figure shows the spectrum of a negative control (no analyte added), and the spectra at two different levels of analyte added. The maximum fluorescence signal for the RFP variant used was observed at 575 nm (excitation wavelength 500 nm). The data in

Access restricted. Please log in or start a trial to view this content.

Discussion

Modifications and troubleshooting

The experiment described in Table 4 can be modified in any way appropriate to the sensors that have been designed. The most important aspect of a chemical sensor is to evaluate its sensitivity and specificity. It is beneficial to ensure that a wide range of concentrations of the analyte is analyzed to determine the useful analytical range of the sensor. It is also worth determining a maximum level of analyte for the cells. Bec...

Access restricted. Please log in or start a trial to view this content.

Disclosures

The authors have no competing financial interests or other conflicts of interest to disclose.

Acknowledgements

The authors wish to acknowledge the students at Longwood University in BIOL 324 (Genetics) and the students in CHEM 403 (Advanced Chemical Laboratory Problem Solving) who were involved in the initial preparation and testing of the antimony and lead biosensors. The idea for MicRoboCop was conceived at the GCAT SynBIO workshop (summer 2014), which is funded by NSF and Howard Hughes Medical Institute and hosted by the University of Maryland Baltimore County. The authors also acknowledge funding received from Longwood University’s Cook-Cole College of Arts and Sciences and the GCAT SynBio Alumni Grant.

Access restricted. Please log in or start a trial to view this content.

Materials

NameCompanyCatalog NumberComments
1,3-dinitrobenzene, 97%AldrichD194255-25G
2,4-dinitrotoluene, 97%Aldrich101397-5G
AgarFisher ScientificBP1423-500
AmpicillinFisher ScientificBP1760-5
Antimony, Reference Standard Solution (1000ppm ±1%/Certified)Fisher ScientificSA450-100Standard in dilute HNO3
Cut Smart BufferNew England BioLabsB7204S
Duplex BufferIntegrated DNA Technologies11-01-03-00
EcoRI-HF Restriction EnzymeNew England BioLabsR3101S
Ethanol, HPLC grade, denaturedAcros OrganicsAC611050040Solvents do not need to be HPLC grade, ACS or reagent grade will work.
Eurofins Genomics SimpleSeq DNA Sequencing KitsEurofins GenomicsSimpleSeq Kit Standard
Forward primer for colony PCRIntegrated DNA Technologies5’- GCCGCTTGAATTCGTCATATAT-3’
Forward primer for DNA sequencingIntegrated DNA Technologies5’- GTAAAACGACGGCCAGTG-3’
IBI Science High Speed Plasmid Mini-kitIBI ScientificIB47101
LB Broth, MillerFisher ScientificBP1426-500
Lead, Reference Standard Solution (1000ppm ±1%/Certified)Fisher ScientificSL21-100Standard in dilute HNO3
LeadOff Disposable Cleaning and Decon WipesHygenall45NRCNSold in canisters or individually wrapped, any alcohol based wipe will work.
Methanol, HPLC gradeFisher ScientificA452-4Solvents do not need to be HPLC grade, ACS or reagent grade will work.
NEB 5-alpha Competent E. coli cellsNew England BioLabsC2987I
NheI-HF Restriction EnzymeNew England BioLabsR3131S
Nuclease free waterNew England BioLabsB1500S
OneTaq 2X Master Mix with Standard BufferNew England BioLabsM0482S
Plasmids from the registry of standard biological parts used for synthetic biologyRegistry of Standard Biological Partshttp://parts.igem.org/Main_Page
Promoter SequencesIntegrated DNA TechnologiesSb promoter: 5’-GCATGAATTCA
GTCATATATGTTTTTGACTTATCC
GCTTCGAAGAGAGAGACACTACCT
GCAACAATCGCTAGCGCAT-3’
3’-CGTACTTAAGCTCACTATA
TACAAAAACTGAATAGGCGAAGC
TTCTCTCTCTGTGATGGACGTTG
TTAGCGATCGCGTA-5’
Pb promoter: 5’-GCATGAATTCG
TCTTGACTCTATAGTAACTAAGGG

TGTATAATCGGCAACGCG
AGCTAGCGCAT-3’
3’-CGTACTTAAGCAGAA
CTGAGATATCATTGATCTCCCACA
TCTTAGCCGTTGCGCTGCGATCGC
GTA-5’
TNT promoter: 5’GCATTCTAGAT
CAATTTATTTGAACAAGGCGGTCA
ATTCTCTTCGATTTTATCTCTCGT
AAAAAAACGTGATACTCATCACAT
CGACGAAACAACGTCACTTATACA
AAAATCACCTGCGAGAGATTAATT
GAATTCGCAT3’
3’CGTAAGATCTAGTTAA
ATAAACTTGTTCCGCCAGTTAAGA
GAAGCTAAAATAGAGAGCATTTTT
TTGCACTATGAGTAGTGTAGCTGC
TTTGTTGCAGTGAATATGTTTTTA
GTGGACGCTCTCTAATTAACTTAA
GCGTA5’
Reverse primer for colony PCRIntegrated DNA Technologies5’- GCCGCTTGAATTCGTCTAGACT- 3’
Reverse primer for DNA sequencingIntegrated DNA Technologies5’- GGAAACAGCTATGACCATG-3’
T4 DNA LigaseNew England BioLabsM0202S

References

  1. Eschner, K. "The Story of the Real Canary in the Coal Mine.". The Smithsonian Magazine. , Smithsonian Institution. (2016).
  2. The Synthetic Biology Project. , Available from: http://www.synbioproject.org/ (2019).
  3. Roda, A., et al. Progress in chemical luminescence-based biosensors: A critical review. Biosensors & Bioelectronics. 76, 164-179 (2016).
  4. He, W., Yuan, S., Zhong, W. H., Siddikee, M. A., Dai, C. C. Application of genetically engineered microbial whole-cell biosensors for combined chemosensing. Applied Microbiology and Biotechnology. 100 (3), 1109-1119 (2016).
  5. Dalby, O., Butler, D., Birkett, J. W. Analysis of Gunshot Residue and Associated Materials-A Review. Journal of Forensic Sciences. 55 (4), 924-943 (2010).
  6. Bell, S., Seitzinger, L. From binary presumptive assays to probabilistic assessments: Differentiation of shooters from non-shooters using IMS, OGSR, neural networks, and likelihood ratios. Forensic Science International. 263, 176-185 (2016).
  7. O'Mahony, A. M., Wang, J. Electrochemical Detection of Gunshot Residue for Forensic Analysis: A Review. Electroanalysis. 25 (6), 1341-1358 (2013).
  8. Vigneshvar, S., Sudhakumari, C. C., Senthilkumaran, B., Prakash, H. Recent Advances in Biosensor Technology for Potential Applications - An Overview. Frontiers in Bioengineering and Biotechnology. 4, 9(2016).
  9. Fernandez, M., Morel, B., Ramos, J. L., Krell, T. Paralogous Regulators ArsR1 and ArsR2 of Pseudomonas putida KT2440 as a Basis for Arsenic Biosensor Development. Applied and Environmental Microbiology. 82 (14), 4133-4144 (2016).
  10. Porter, S. E. G., Barber, A. E., Colella, O. K., Roach, T. D. Using Biological Organisms as Chemical Sensors: The MicRoboCop Project. Journal of Chemical Education. 95 (8), 1392-1397 (2018).
  11. Borremans, B., Hobman, J. L., Provoost, A., Brown, N. L., Van der Lelie, D. Cloning and functional analysis of the pbr lead resistance determinant of Ralstonia metallidurans CH34. Journal of Bacteriology. 183 (19), 5651-5658 (2001).
  12. Hobman, J. L., Julian, D. J., Brown, N. L. Cysteine coordination of Pb(II) is involved in the PbrR-dependent activation of the lead-resistance promoter, PpbrA, from Cupriavidus metallidurans CH34. Bmc Microbiology. 12, (2012).
  13. Yagur-Kroll, S., Amiel, E., Rosen, R., Belkin, S. Detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene by an Escherichia coli bioreporter: performance enhancement by directed evolution. Applied Microbiology and Biotechnology. 99 (17), 7177-7188 (2015).
  14. Gorman, M. "Guns in America: The Debate Over Lead Based Bullets.". Newsweek. , (2017).
  15. Yuksel, B., Ozler-Yigiter, A., Bora, T., Sen, N., Kayaalti, Z. GFAAS Determination of Antimony, Barium, and Lead Levels in Gunshot Residue Swabs: An Application in Forensic Chemistry. Atomic Spectroscopy. 37 (4), 164-169 (2016).
  16. Blakey, L. S., Sharples, G. P., Chana, K., Birkett, J. W. Fate and Behavior of Gunshot Residue-A Review. Journal of Forensic Sciences. 63 (1), 9-19 (2018).
  17. Yagur-Kroll, S., et al. Escherichia coli bioreporters for the detection of 2,4-dinitrotoluene and 2,4,6-trinitrotoluene. Applied Microbiology and Biotechnology. 98 (2), 885-895 (2014).

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Explore More Articles

Bacterial BiosensorGunshot Residue DetectionForensic ApplicationsSynthetic BiologyFluorescent ProteinPlasmid DNAEcoRINHEL EnzymesPromoter DNAT4 DNA LigasePCR ReactionE Coli TransformationLB ampicillin Agar PlateUndergraduate Research

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2025 MyJoVE Corporation. All rights reserved