Method Article
We describe a novel technique for heterotopic abdominal heart-lung transplantation (HAHLT) in rats. The transplant configuration results in a partially loaded graft circulation, allowing direct functional assessment. This model may be employed for acute or chronic studies of function and immunologic status of the transplanted graft.
Herein, we describe a novel technique for heterotopic abdominal heart-lung transplantation (HAHLT) in rats. The configuration of the transplant graft involves anastomosis of donor inferior vena cava (IVC) to recipient IVC, and donor ascending aorta (Ao) to recipient abdominal Ao. The right upper and middle lung lobes are preserved and function as conduits for blood flow from right heart to left heart.
There are several advantages to using this technique, and it lends itself to a broad range of applications. Because the graft is transplanted in a configuration that allows for dyamic volume-loading, cardiac function may be directly assessed in vivo. The use of pressure-volume conductance catheters permits characterization of load-dependent and load-independent hemodynamic parameters. The graft may be converted to a loaded configuration by applying a clamp to the recipient’s infra-hepatic IVC. We describe modified surgical techniques for both donor and recipient operations, and an ideal myocardial protection strategy. Depending on the experimental aim, this model may be adapted for use in both acute and chronic studies of graft function, immunologic status, and variable ventricular loading conditions. The conducting airways to the transplanted lung are preserved, and allow for acute lung re-ventilation. This facilitates analysis of the effects of the mixed venous and arterial blood providing coronary perfusion to the graft.
A limitation of this model is its technical complexity. There is a significant learning curve for new operators, who should ideally be mentored in the technique. A surgical training background is advantageous for those wishing to apply this model. Despite its complexity, we aim to present the model in a clear and easily applicable format. Because of the physiologic similarity of this model to orthotopic transplantation, and its broad range of study applications, the effort invested in learning the technique is likely to be worthwhile.
The first rodent model of heterotopic abdominal heart transplantation (HAHT) was described by Abbott and colleagues in 19641. This technique, and subsequent modifications have been widely applied to characterize transplant graft function and immunologic status. The majority of HAHT techniques described involve a non-volume loaded heart2,3. Models of HAHT involving volume-loaded ventricles have been described, but they are frequently limited in one or more respects.
Heterotopic abdominal heart-lung transplantation (HAHLT) with a volume-loaded left ventricle (LV) has been described previously. Chen and colleagues4, and subsequently Ibrahim and colleagues5 described HAHLT with a single aorto-aortic (donor ascending to recipient abdominal aorta) anastomosis. The only volume load presented to the ventricle in this circulation is the coronary venous return. Asfour and colleagues described a HAHT technique in which the lung circuit was eliminated by anastomosing donor pulmonary artery (PA) to donor left atrium (LA)6. In this circulation, venous inflow to right ventricle (RV) occurs via a donor SVC to recipient IVC anastomosis, and the subsequent LV load is ejected into the aorto-aortic anastomosis. Cardiac function was partially assessed in vivo, and also in vitro using a Langendorff rig. Figueiredo and colleagues described a HAHLT model similar to our own7, but in mice. Venous inflow to the RV occurs via donor SVC to recipient IVC anastomosis. Blood subsequently passes through the single lung circulation and LV load is ejected into the aorto-aortic anastomosis. Cardiac function in their study was assessed by magnetic resonance imaging (MRI). Wen and colleagues described a unique HAHT technique in which the LV is loaded by means of a recipient aorta to donor LA anastomosis8. The LV, therefore, fills at systemic pressures. Cardiac function, and whether LV stroke volume is ejected antegradely in their model was not assessed.
Many of the techniques referenced above involve non-physiologic LV loading conditions, including the techniques whose partial LV load is represented only by coronary venous return. On the other hand, many techniques do approach physiologic LV loading. The majority of these techniques, as with the technique of Asfour and colleagues, omit the pulmonary circulation and utilize a donor PA to donor LA anastomosis6,9. The circulation described by Galinanes and colleagues10 employs a direct recipient cava to donor LA anastomosis, omitting the pulmonary circulation and the right heart. Yokoyama and colleagues achieve the same effect by ligating the donor PA and creating an interatrial communication in the donor heart (omitting donor lung and right heart circulations)11. The circulation of Maruyama and colleagues12 involves an anastomosis between donor left PA and recipient Ao, which permits LV filling via the pulmonary circulation as a conduit, but effectively excludes the right heart.
In cases where near physiologic loading conditions were met, we advance the technique of HAHLT in 2 major respects. First, to our knowledge, the exact configuration we report has not been described in rats. It is possibly the most versatile circulation for investigators wishing to study the physiology, structure, and immunology of the transplanted heart-lung graft. Second, we describe how the function of the transplant graft can be directly characterized in vivo. For this application, pressure-volume conductance catheters can be introduced directly into the LV apex of the transplant graft, which allows for complete cardiac functional characterization.
The technique described here can be applied to both acute and chronic studies of transplant graft function, while the functional assessment may be performed either in vivo or in vitro. We present a model in which the loading conditions can be near physiologic, however the degree of ventricular loading may be manipulated both acutely and chronically by diverting venous return towards or away from the graft. Afterload conditions can also be manipulated. Because the lung and its airway are retained in this transplant configuration, investigators can re-ventilate the donor lung acutely. Uniquely, lung re-ventilation changes the composition of blood perfusing the transplant coronary arteries. Under non-ventilated conditions, blood ejected from the donor aorta is deoxygenated, and mixes with oxygenated blood in the recipient aorta. Under acutely ventilated conditions, ejected blood becomes oxygenated. Thus, transplant graft function can be compared under ventilated and non-ventilated conditions, and also under variably loaded conditions.
The protocol below describes important modifications to previously described HAHLT donor and recipient operations. It also describes an optimal technique for protecting the transplant graft throughout the period of ischemia (time between donor explant and recipient implant). Advantages of this technique include physiologic conditions potentially approaching that of an orthotopically transplanted graft, and a wide range of investigative applications. An important limitation is its technical complexity. With adequate mentoring and practice, the advantages of this technique will likely outweigh the challenges in adopting it.
すべての動物を飼育し、実験動物の管理と使用のための国家と制度ガイドラインに従って世話しました。このプロトコルの倫理承認は、ブリティッシュコロンビア州の動物管理委員会の大学によって付与されました。 300との間体重の雄、SDラット - 450 gが、このプロトコルのために使用しました。
1.ドナー操作
心肺移植片の調製
注:この手順のこの部分を完了しながら、アシスタントが受信者のげっ歯類を麻酔し、移植片移植の準備をする必要があります。
3.受信者の操作
上記のHAHLT技術は、高度な技術であり、詳細には細心の注意が必要です。 表1のハイライト失敗手順対成功に関連付けられており、技術的な問題のトラブルシューティングを行うためのガイドとして使用することができる重要な要因のいくつか。
受信者の大動脈がアンクランプされた後、グラフト冠状動脈は酸素を豊富に含んだ血液でいっぱいに見られるべ?...
ここに記載の技術の成功は、いくつかの要因に基づいて予測されます。それらの中のキーは、両方のドナーとレシピエント動物の安定性を確保し、安全かつ最小限の血液損失に関連付けられている細心の手術技術を採用し、均一なグラフト冷却との完全な心停止停止を確保し、総虚血時間を最小限に抑え、かつ適切に移植片を脱気されます。上記認めたように、技術者の技術的な複雑さは、?...
著者らは、開示することは何もありません。
マーク·J·カーンズは(医師とカナダの外科医のロイヤルカレッジオブを通じて受賞)UBC臨床医研究者プログラムからの支援を受け、UBC 4YF博士フェローシップ。
ジョン·H·ボイドは、ナショナルSanitorium協会と保健研究奨学生のためのマイケルスミス財団です。 CIHRを通じて資金調達。著者らは、灌流機器のセットアップやメンテナンスとの支援のために博士M.アラードとリチャードWamboldtに感謝したいと思います。
Name | Company | Catalog Number | Comments |
Celsior Cardioplegic Soution | Genzyme | The solution is kept on ice throughout the procedure. We prepare our own solution, with slight modifications. | |
Rodent Ventilator | Harvard Apparatus | Model 683 | |
Vital Sign Monitor | Nonin | Model 9847V | Displays SpO2 and heart rate. |
IV Cannulae | Jelco | 3063 | 24 - 26 G x 3/4" cannulae. |
IV Tubing | CareFusion | MP9259-C | Short-length connector tubing (18 cm). |
Surgical Clips | Teleflex Medical | 001204 | Horizon titanium ligating clips. |
Sutures | Ethicon, Sharpoint | LA54G, AK-0107 | 3-0 silk reel, and 9-0 prolene suture (single-armed, DR5 needle). |
Surgical Instruments | Not Applicable | Not Applicable | The instruments used are generic, and can be purchased from any surgical supply company. |
このJoVE論文のテキスト又は図を再利用するための許可を申請します
許可を申請This article has been published
Video Coming Soon
Copyright © 2023 MyJoVE Corporation. All rights reserved