Summary

Glass wool filters have been used to concentrate waterborne viruses by a number of research groups around the world. Here we show a simple approach for constructing glass wool filters and demonstrate the filters are also effective in concentrating waterborne viral, bacterial and protozoan pathogens.

Abstract

The key first step in evaluating pathogen levels in suspected contaminated water is concentration. Concentration methods tend to be specific for a particular pathogen group, for example US Environmental Protection Agency Method 1623 for Giardia and Cryptosporidium1, which means multiple methods are required if the sampling program is targeting more than one pathogen group. Another drawback of current methods is the equipment can be complicated and expensive, for example the VIRADEL method with the 1MDS cartridge filter for concentrating viruses2. In this article we describe how to construct glass wool filters for concentrating waterborne pathogens. After filter elution, the concentrate is amenable to a second concentration step, such as centrifugation, followed by pathogen detection and enumeration by cultural or molecular methods. The filters have several advantages. Construction is easy and the filters can be built to any size for meeting specific sampling requirements. The filter parts are inexpensive, making it possible to collect a large number of samples without severely impacting a project budget. Large sample volumes (100s to 1,000s L) can be concentrated depending on the rate of clogging from sample turbidity. The filters are highly portable and with minimal equipment, such as a pump and flow meter, they can be implemented in the field for sampling finished drinking water, surface water, groundwater, and agricultural runoff. Lastly, glass wool filtration is effective for concentrating a variety of pathogen types so only one method is necessary. Here we report on filter effectiveness in concentrating waterborne human enterovirus, Salmonella enterica, Cryptosporidium parvum, and avian influenza virus.

Protocol

1. Preparing the Glass Wool

  1. Before and after making each batch of filters, sterilize the work area with 10% bleach solution.
  2. Put on gloves and gown. Sterilize a bucket by autoclaving at 121°C and 15 psi for at least 20 minutes. Place the glass wool in the sterile bucket.
  3. Saturate the glass wool with reverse osmosis water and let soak for 15 minutes.
  4. Drain the reverse osmosis water from the bucket.
  5. Saturate the glass wool with 1 M HCl and let soak for 15 minutes.
  6. Drain the 1 M HCl from the bucket.
  7. Rinse the glass wool with reverse osmosis water.
  8. Mix thoroughly.
  9. Check the pH using pH paper and repeat the reverse osmosis water rinse until a neutral pH is achieved.
  10. Pour off the rinse water.
  11. Saturate the glass wool with 1 M NaOH and let soak for 15 minutes.
  12. Drain the 1 M NaOH from the bucket.
  13. Repeat the reverse osmosis rinse until a neutral pH is achieved.
  14. Pour off the rinse water.
  15. Instead of a bucket, a glass wool washer can be constructed, which is similar in design to a glass pipette washer (Figure 1).
  16. Cover the glass wool completely with sterile Phosphate Buffered Saline (PBS) adjusted to pH 6.8.
  17. Use prepared glass wool immediately or store at 4°C. It can be stored for up to two weeks. Before using, make sure the pH is neutral as it will rise over time. If the pH is not neutral, re-rinse with sterile Phosphate Buffered Saline (pH 6.8).

2. Assembling the Glass Wool Filter

  1. Drill a 11/16 inch hole into the PVC caps and tap threads so the male adapter nylon fittings can be screwed into the caps. This step is necessary only for the first assembly. Thereafter, the caps can be used for years. Apply Teflon tape to the nylon fittings threads and screw to the caps.
  2. Pack the PVC pipe with small pieces of glass wool. Use a metal plunger, like a car engine valve, to pack tight. Packing does not require great force. Pack tight enough so that the glass wool stays in place and channels do not form. However, do not pack so tightly water cannot flow through the filter. When packed appropriately, a flow rate of 4 to 5 liters per minute should be attainable when the filter is attached to water taps with pressures between 40-60 psi. For the size of PVC pipe specified in this protocol, approximately 85 grams washed and packed glass wool is used per pipe. Tare the empty PVC pipe on a top-loading balance and pack with washed glass wool until the pipe mass increases 85 grams.
  3. Insert polypropylene mesh into the PVC caps with male adapter nylon fittings attached.
  4. Apply Teflon tape to the threaded portions of the PVC pipe.
  5. Screw on PVC caps to the PVC pipe and label one filter end the inflow and the other end the outflow. This is important later for the elution step. Which end is labeled inflow does not matter.
  6. Push 60 mL of sterile Phosphate Buffered Saline (pH = 6.8) into the filter using a catheter tipped syringe. Excess will come out opposite end.
  7. Wrap ends tightly with Parafilm to avoid leaking. Filters can be stored up to 30 days at 4°C.

3. Sampling

  1. Sterilize tubing used for sampling by recirculating or immersing items for 30 minutes in 0.525% NaClO (i.e., a 10% solution of standard household bleach). Follow this by draining the hypochlorite solution and neutralize with 0.05% sodium thiosulfate, made by adding 25 mL of a 2% stock anhydrous sodium thiosulfate solution to one liter of reverse osmosis water.
  2. For sample water with a pH greater than 7.5, adjust the pH to between 6.5 and 7.0 with HCl. HCl concentration can range from 0.25 M to 1 M. Four liters 0.5 M HCl is generally sufficient for two 800 liter samples, depending on the water's ambient pH and buffering capacity. Inject HCl during sampling using a peristaltic pump or Venturi (Figure 2). Adjust the pump speed or Venturi opening to achieve the target pH. Measure the pH at the sample line outlet using a field pH meter.
  3. Use a prefilter if the glass wool filter clogs from water with high turbidity. (Specifications for the prefilter and its housing are in the Materials list online.) Because pathogens can be attached to particles trapped by the prefilter it must be eluted along with the glass wool filter (see below).
  4. Adjust the flow rate to between 2 and 4 liters/minute. Typical sample volumes are between 200 and 1,500 liters.
  5. Disconnect the glass wool filter and store in a plastic sterile bag at 4°C for up to 48 hours.

4. Elution

  1. Affix the glass wool filter to a ring stand with the sample inflow end pointing downward into a polypropylene bottle. Elute opposite of the direction of sample flow.
  2. Push 80 mL of sterile 3% beef extract in 0.05 M glycine with a pH of 9.5 into the filter.
  3. Wait 15 minutes.
  4. Push another 80 mL of sterile 3% beef extract in 0.05 M glycine with a pH of 9.5 into the filter.
  5. Push air thorough the filter until foam comes out of the filter inlet.
  6. Adjust the eluate pH to between 7.0 and 7.5 with 1 M HCl.
  7. Store eluate at 4°C for up to 24 hours or at -20°C for longer periods of time.
  8. Elute the prefilter if one is used. Unscrew the top of the housing cartridge and pour off all residual water inside the housing while holding the prefilter in place with sterile gloved hands.
  9. Remove the prefilter from the housing cartridge and slip it into a 15" x 6" zip-lock bag.
  10. Pour 200 mL of sterile 3% beef extract in 0.05 M glycine with a pH of 9.5 into the bag and seal securely with the zip-lock.
  11. Invert the bagged prefilter several times to ensure the entire surface comes in contact with the beef extract.
  12. Wait 15 minutes, occasionally inverting and massaging the bagged prefilter.
  13. Open the zip-lock. Grip the bag around the prefilter tightly to squeeze out as much beef extract as possible and pull the prefilter out with sterile gloved hands,.
  14. Pour the beef extract eluate into a polypropylene bottle.
  15. Adjust the eluate pH to between 7.0 and 7.5 with 1M HCl.
  16. Store eluate at 4°C for up to 24 hours or at -20°C for longer periods of time. The prefilter eluate can be separately analyzed for pathogens or combined with the glass wool filter eluate.

5. Representative Results

PathogenWater Turbidity Level (NTU) aAmount Seeded/L b,c,d% Recovery ± 1 SDNumber Independent Trials
Enterovirus- Poliovirus Sabin III0.5 50081% ± 117
Enterovirus- Poliovirus Sabin III0.5500067% ± 128
Enterovirus- Poliovirus Sabin III215 50059% ± 327
Enterovirus- Poliovirus Sabin III215500038% ± 226
Enterovirus- Poliovirus Sabin III44750056% ± 188
Enterovirus- Poliovirus Sabin III447500063% ± 378
Cryptosporidium parvum0.5538% ± 147
Cryptosporidium parvum0.55053% ± 198
Cryptosporidium parvum215540% ± 167
Cryptosporidium parvum2155030% ±66
Cryptosporidium parvum447533% ± 138
Cryptosporidium parvum4475028% ± 118
Salmonella enterica0.5529% ± 247
Salmonella enterica0.550056% ± 168
Salmonella enterica215532% ± 247
Salmonella enterica21550034% ±116
Salmonella enterica447534% ± 188
Salmonella enterica44750031% ± 248
  1. Nephelometric Turbidity Unit
  2. Enteroviruses enumerated by qPCR as genomic copies/L
  3. C. parvum enumerated by immunofluorescence as oocysts
  4. S. enterica enumerated by culture as colony-forming-units

Table 1. Glass wool concentration with varying water turbidities and pathogen densities.

PathogenWater Sample LocationAmount Seeded/La% Recovery
Avian Influenza H5N2Sundi Lake, Anchorage Borough250042.9%
Avian Influenza H5N2Minto Flats, Fairbanks North Star Borough250036.7%
Avian Influenza H5N2Portage Valley, Anchorage Borough25007.8%
Avian Influenza H5N2Potter Marsh, Anchorage Borough250041.5%
Avian Influenza H5N2Willow Lake, Yukon-Koyukuk Borough250015.5%
  1. Measured by qPCR as genomic copies/L

Table 2. Glass wool concentration of avian influenza virus using water from five sites in Alaska.

figure-protocol-11988
Figure 1. Diagram of glass wool washer. This can be used instead of a bucket, saving time from rinsing. The concept is similar to a glass pipette washer.

figure-protocol-12258
Figure 2. Glass wool filtration with acid injection by peristaltic pump. Note the "T" connector where the pump tubing introduces acid into the sample line between the water tap and glass wool filter. pH adjustment is necessary only if the water sampled has a pH > 7.5.

Glass wool filters are effective in concentrating pathogens from water with a wide range of turbidity levels and pathogen densities (Table 1). To test this, 20 liters dechlorinated tap water was mixed with dried silt loam soil (0, 1.27, or 2.75 g/L) to achieve the desired level of turbidity and then seeded with pathogens at various densities. The water was passed through a glass wool filter, the concentrated pathogens in the eluate were enumerated, and this value was the numerator in the percent recovery calculation. The quantity of pathogens seeded into the water, that is, the denominator of the percent recovery calculation, was determined by first seeding the pathogens into a negative eluate then enumerating the pathogens. The negative eluate was prepared by passing an unseeded 20 liter sample through a filter and eluting. Quantifying the seeded pathogens in a negative eluate avoids differences in pathogen enumeration that could result from matrix differences created by the glass wool filter. The importance of this step when quantifying pathogens by qPCR is discussed in Lambertini et al.3. A 20 liter negative control sample was concentrated via glass wool filtration to determine there were no native pathogens present that could confound the percent recovery calculation. A 10 μm nominal pore size prefilter was used when the turbidity level was ≥ 215 NTU.

Poliovirus was quantified by real-time qPCR using the secondary concentration and nucleic acid extraction procedures and primers and probe described in Lambertini et al.3. Cryptosporidium parvum was quantified in the final concentrated sample volume (FCSV) created by the secondary concentration procedure for poliovirus. Oocysts were visualized by immunofluorescence (MeriFluor Cryptosporidium & Giardia Detection Kit, Meridian Life Science, Inc., Cincinnati, OH). Salmonella enterica was quantified in the FCSV by plating onto XLD agar (Remel, Lenexa, KS) and counting colony-forming-units.

Glass wool filters are effective in concentrating avian influenza viruses (Table 2). Low pathogenicity avian influenza virus (H5N2) was seeded into water from several locations in Alaska and the percent recovery calculated as described above. Secondary concentration and nucleic acid procedures were performed as for poliovirus; the virus was quantified by qPCR using the primers and probe described in Spackman et al.4

Discussion

Glass wool filters have been used by several research teams3,5,6 to concentrate human enteric viruses from a variety of water sources such as finished drinking water7, groundwater8,9, surface water10, sea water11, wastewater12, and agricultural runoff13. Here we report the filters are also effective in concentrating avian influenza virus as well as the bacterial and protozoan pathogens Salmonella enterica (serovar Typhimurium) and C...

Disclosures

No conflicts of interests declared.

Acknowledgements

We thank William T. Eckert for narrating the video. Development of the glass wool protocol was part of the Wisconsin Water And Health Trial for Enteric Risks (WAHTER Study), funded by US EPA STAR Grant R831630. Alaska samples were collected by A. Reeves, A. Ramey, and B. Meixell with financial support from USGS. Any use of trade, product, or firm names is for descriptive purposes only and does not imply endorsement by the U.S. Government.

Materials

NameCompanyCatalog NumberComments
Name of reagent or item CompanyCatalogue number
Hydrochloric acidFisher ScientificA144-500
Sodium hydroxideFisher ScientificBP359-212
Phosphate Buffered Saline
Sodium chloride
Potassium phosphate-dibasic
Potassium phosphate-monobasic

Fisher Scientific
Fisher Scientific
Fisher Scientific

BP358-212
BP363-500
BP362-500
Sodium hypochlorite i.e., household bleachThe Clorox Co. 
Sodium thiosulfate, anhydrousFisher ScientificS 475-212
Beef extract, desiccated Becton, Dickinson and Company211520
GlycineFisher ScientificG46-500
Oiled sodocalcic glass wool
Or
R-11 unfaced fiberglass insulation
Isover

Johns Manville
Bourre 725 QN


Polypropylene mesh Industrial NettingxN4510
2"x4" Sch 80 PVC threaded pipe nipple Grainger6MW35
2" Sch 40 PVC capGrainger5WDW3
Male adapter nylon fitting (1/2"x1/2") US Plastic Corp.62178
Sample bottles for eluate- 1 literFisher Scientific03-313-4F
60 mL syringeFisher ScientificNC9661991
pH stripsWhatman2614 991
Prefilter, Polypropylene, 10 inch cartridge, 10 μmMcMaster-Carr4411K75
Prefilter housingCole-ParmerS-29820-10

References

  1. US Environmental Protection Agency. Method 1623: Cryptosporidium and Giardia in Water by Filtration/IMS/FA. EPA 815-R-05-002. , (2012).
  2. Cashdollar, J. L., Dahling, D. R. Evaluation of a method to re-use electropositive cartridge filters for concentrating viruses from tap and river water. J. Virol. Methods. 132, 13-17 (2006).
  3. Lambertini, E. Concentration of enteroviruses, adenoviruses, and noroviruses from drinking water by use of glass wool filters. Appl. Environ. Microbiol. 74, 2990-2996 (2008).
  4. Spackman, E. Development of a real-time reverse transcription PCR assay for Type A influenza virus and the avian H5 and H7 hemagglutinin subtypes. J. Clin. Microbiol. 40, 3256-3260 (2002).
  5. Environment Agency. Optimisation of a new method for detection of viruses in groundwater. Report No. NC/99/40. , (2000).
  6. Vilaginés, P., Sarrette, B., Husson, G., Vilaginés, R. Glass wool for virus concentration at ambient water pH level. Water Sci. Technol. 27, 299-306 (1993).
  7. Vivier, J. C., Ehlers, M. M., Grabow, W. O. Detection of enteroviruses in treated drinking water. Water Res. 38, 2699-2705 (2004).
  8. Powell, K. L., Sililo, O. . Enteric virus detection in groundwater using a glass wool trap. In: Groundwater: Past Achievements and Future Challenges. , 813-816 (2000).
  9. Hunt, R. J., Borchardt, M. A., Richards, K. D., Spencer, S. K. Assessment of sewer source contamination of drinking water wells using tracers and human enteric viruses. Environ. Sci. Technol. 44, 7956-7963 (2010).
  10. van Heerden, J., Ehlers, M. M., Heim, A., Grabow, W. O. Prevalence, quantification and typing of adenoviruses detected in river and treated drinking water in South Africa. J. Appl. Microbiol. 99, 234-242 (2005).
  11. Vilaginés, P. Round robin investigation of glass wool method for poliovirus recovery from drinking water and sea water. Water Sci. Technol. 35, 445-449 (1997).
  12. Gantzer, C., Senouci, S., Maul, A., Levi, Y., Schwartzbrod, L. Enterovirus genomes in wastewater: concentration on glass wool and glass powder and detection by RT-PCR. J. Virol. Methods. 65, 265-271 (1997).
  13. Borchardt, M. A., Jokela, W. E., Spencer, S. K. Pathogen losses in surface water runoff from dairy manure applied to corn fields. , (2011).
  14. Deboosere, N. Development and validation of a concentration method for the detection of influenza A viruses from large volumes of surface water. Appl. Environ. Microbiol. 77, 3802-3808 (2011).
  15. Lambertini, E. Virus contamination from operation and maintenance practices in small drinking water distribution systems. J. Water Health. 9, 799-812 (2011).

Reprints and Permissions

Request permission to reuse the text or figures of this JoVE article

Request Permission

Explore More Articles

Glass Wool FiltersConcentrationWaterborne VirusesAgricultural Zoonotic PathogensPathogen LevelsSampling ProgramConcentration MethodsEquipmentVIRADEL Method1MDS Cartridge FilterFilter ElutionCentrifugationPathogen DetectionEnumerationCultural MethodsMolecular MethodsAdvantagesConstructionSampling RequirementsInexpensive Filter PartsLarge Sample VolumesSample TurbidityPortable FiltersField Sampling

This article has been published

Video Coming Soon

JoVE Logo

Privacy

Terms of Use

Policies

Research

Education

ABOUT JoVE

Copyright © 2025 MyJoVE Corporation. All rights reserved