Résumé

A protocol involving integrated concentration, enrichment, and end-point colorimetric detection of foodborne pathogens in large volumes of agricultural water is presented here. Water is filtered through Modified Moore Swabs (MMS), enriched with selective or non-selective media, and detection is performed using paper-based analytical devices (µPAD) imbedded with bacterial-indicative colorimetric substrates.

Résumé

This protocol describes rapid colorimetric detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from large volumes (10 L) of agricultural waters. Here, water is filtered through sterile Modified Moore Swabs (MMS), which consist of a simple gauze filter enclosed in a plastic cartridge, to concentrate bacteria. Following filtration, non-selective or selective enrichments for the target bacteria are performed in the MMS. For colorimetric detection of the target bacteria, the enrichments are then assayed using paper-based analytical devices (µPADs) embedded with bacteria-indicative substrates. Each substrate reacts with target-indicative bacterial enzymes, generating colored products that can be detected visually (qualitative detection) on the µPAD. Alternatively, digital images of the reacted µPADs can be generated with common scanning or photographic devices and analyzed using ImageJ software, allowing for more objective and standardized interpretation of results. Although the biochemical screening procedures are designed to identify the aforementioned bacterial pathogens, in some cases enzymes produced by background microbiota or the degradation of the colorimetric substrates may produce a false positive. Therefore, confirmation using a more discriminatory diagnostic is needed. Nonetheless, this bacterial concentration and detection platform is inexpensive, sensitive (0.1 CFU/ml detection limit), easy to perform, and rapid (concentration, enrichment, and detection are performed within approximately 24 hr), justifying its use as an initial screening method for the microbiological quality of agricultural water.

Introduction

It is important that foodborne disease agents are detected rapidly and preferably in field-based settings in order to reduce the burden of foodborne disease. Common strategies to detect foodborne bacterial pathogens include biochemical profiling, selective and differential culturing, immunological isolation and detection, and molecular detection. However, these methods are hampered by sporadic contamination, small sample sizes tested, the often low concentrations of the foodborne pathogenic bacteria, require long processing times, and/or are not applicable for field settings. Further, compounds in many food matrices are inhibitory to detection and diagnostic applications. In order to improve the likelihood of microbial detection, the United States Food and Drug Administration has suggested that testing agricultural water (such as wash water and irrigation water) which either comes in contact with a large surface area of fresh produce or serves as a vehicle for produce contamination is a viable alternative to direct testing of food1. Even so, the often low natural pathogen-burden coupled with the dilution effect of the representative agricultural water sample makes sample preparation methods for pathogen concentration essential. Such a method would require sampling large volumes of water (≥10 L), adequate pathogen-concentration, and compatibility with downstream detection strategies.

Modified Moore swabs (MMS) are inexpensive, simple, and rugged devices used for concentrating bacteria from large volumes (≥10 L) of water2-4. The MMS consists of a plastic cassette filled with gauze, which serves as a coarse filter for large volumes of water pumped through the cassette using a peristaltic pump. The MMS is a non-discriminatory method of bacterial concentration (≥10 fold concentration) that captures organic and inorganic particulate material including microorganisms in processed liquid samples. It is likely that the excellent efficacy of concentration of target microorganisms by the MMS can be explained by the fact that microorganisms are expected to be attached to the silt-clay fraction or organic micro-aggregates of the suspended solids3. The rugged design of the MMS allows for overcoming most shortcomings associated with other filtration methods for capture and concentration of bacteria from water, such as clogging of filters, inability to process large volumes, filter samples with high turbidity, and high costs. For these reasons, the FDA is recommending that MMS’s be incorporated into official procedures for environmental and produce-related sample collection procedures5.

Here, a method is described for the concentration, enrichment, and detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from agricultural waters. A MMS is used for concentration of bacteria, and also serves as a vessel for selective or non-selective bacterial enrichment. Bacterial detection is achieved biochemically using paper-based analytical devices (µPADs)6. µPADs can be manufactured as fluidic networks or spot tests using a variety of methods including photolithography, inkjet printing, stamping, and wax printing7-11. Examples of fluidic designs can be dendritic channel patterns where the sample is deposited in the center and subsequently flows to distal reservoirs or single channel patterns in which the sample or substrate are pulled from the outer reservoirs of the channel by capillary action into the center12. For this protocol, we have chosen to employ for 7-mm-diameter wax-paper spot arrays imbedded with chromogenic substrates that can be processed by enzymes indicative of the microorganisms tested here: Chlorophenol red β-D-galactopyranoside (CPRG) and 5-bromo-4-chloro-3-indolyl β-D-glucuronide (X-Gluc) for detection of β-galactosidase and β-glucuronidase produced by E. coli; 5-bromo-6-chloro-3-indolyl caprylate (magenta caprylate) for the detection of C8-esterase produced by Salmonella spp.; and 5-bromo-4-chloro-3-indolyl-myo-inositol phosphate (X-InP) for detection of phosphatidylinositol-specific phospholipase C (PI-PLC) produced by L. monocytogenes6. Thus, the presence of a particular bacterium can be observed visually without the need for complex equipment or data interpretation. The specificity and sensitivity of the enzyme-based colorimetric µPAD detection of these specific target bacteria has been previously explored6. In addition, the sensitivity of the integrated concentration-detection method for these target bacteria was evaluated by spiking of large volumes of water with pre-determined levels of microorganisms (unpublished data and Bisha et al.13).

Protocole

1. Concentration of Bacteria from Large Volumes of Agricultural Water Using MMS

  1. MMS Preparation
    1. Cut a rectangular section of 4-ply cheesecloth measuring 40 x 12 cm.
    2. Fold the cheesecloth along both axes to obtain a rectangle of 20 x 6 cm.
    3. Roll the cheesecloth tightly along its long axis to form a cylindrical swab of approximately 6 cm tall and 3 cm in diameter.
    4. Autoclave the cheesecloth swab in aluminum foil, do not autoclave the cassette. Decontaminate the cassette by soaking it for 30 min in 10% household bleach, and deactivate the residual chlorine by soaking the cassette for 15 min in a sodium thiosulfate pentahydrate (Na2S2O3·5H2O) solution (50 mg/L prepared in sterile water).
    5. Insert the swab into the MMS cassette.
      NOTE: If the non-disposable version of the MMS cassette is used, start with a 4-ply sheet of cheesecloth measuring 80 x 22 cm, fold it to 40 x 11 cm and roll it to form a cylinder approximately 11 cm tall and 6 cm in diameter.
    6. Assemble the MMS.
    7. Attach vinyl tubing to spigots on both sides of the MMS, ensuring the tubing fully adheres to the spigots, and fix tubing into the peristaltic pump. Ensure that the tubing upstream of the peristaltic pump is of sufficient length for sampling.
  2. Concentration of Bacteria
    1. Sample at least 10 L of agricultural water by running the peristaltic pump at high speed.
    2. After sampling is complete, withdraw the peristaltic pump inlet from the water sample and continue running the pump until no effluent water is observed exiting the MMS.
    3. If a manifold is used to run several samples at the same time, collect the effluent of each MMS, and when 10 L is filtered through a single MMS close the valve for that particular MMS and continue running the pump.
      1. When sampling is completed, withdraw the peristaltic pump inlet from the agricultural water, open all the valves of the manifold, and continue running the pump until no effluent water is observed exiting the MMSs.
  3. When concentration has been completed for all MMSs, carefully remove the vinyl tubing from the MMS spigots and cap the spigots on both sides of the MMS. Tightly capped MMS can be stored for up to 12 hr before adding enrichment media.

2. MMS Enrichment and Sample Preparation

  1. Enrichment
    1. Unscrew the lid of the MMS, and aseptically add 20 ml of the appropriate sterile enrichment broth. Use one MMS for each selective enrichment. Alternatively, perform a non-selective enrichment to propagate all three target bacteria in the same sample.
      NOTE: If the non-disposable version of the MMS cassette is used, aseptically remove cheesecloth filter from the cassette and place in a sterile bag before adding 225 ml of the appropriate enrichment media.
      1. For enrichment of E. coli, add 20 ml of buffered peptone water (BPW) supplemented with 8 mg/L of vancomycin hydrochloride.
      2. For enrichment of Salmonella spp., add 20 ml of BPW supplemented with the Salmonella supplement (4 ml/L).
      3. For enrichment of L. monocytogenes, add 20 ml of VIDAS UP Listeria (LPT) broth.
      4. For simultaneous non-selective enrichment for all three microorganisms using a single MMS, use universal preenrichment broth (UPB).
    2. Screw the lid of the MMS back on tightly. Ensure that the spigots are tightly capped to avoid spills and possible contamination during enrichment.
    3. Incubate the MMS for up to 18-24 hr in a shaking incubator at 200 rpm. Use 42 °C for E. coli and Salmonella spp. selective enrichments. Use 30 °C for L. monocytogenes selective enrichment, and use 37 °C for non-selective enrichment.
  2. Sample Preparation
    1. When incubation has completed, remove the MMS from the incubator, uncap one of the spigots, and gently dispense about 0.5 ml into a 1.5 ml microcentrifuge tube. Alternatively, unscrew the MMS and pipette out 0.5 ml of overnight enrichment.
      NOTE: If the not-disposable version of the MMS cassette is used, pipette 0.5 ml of enrichment from the bag.
    2. For colorimetric analysis of E. coli selective enrichment, or for the analysis of the non-selective enrichments, sonicate 0.5 ml of enrichment at 5 W, 22 kHz for 20 sec using a probe sonicator.

3. Preparation and Embedding of Colorimetric Substrates in µPADs

  1. Prepare enough µPADs for each sample and target tested. To detect E. coli prepare CPRG and X-Gluc µPADs, for Salmonella spp. detection prepare MC µPADs, and for L. monocytogenes detection prepare X-InP µPADs.
    1. Prepare HEPES buffer [0.1 M HEPES with 0.1% Bovine Serum Albumin (BSA)] for the colorimetric substrates and adjust the pH of the buffer according to the substrate that is going to be used: pH 7.5 for preparation of CPRG or X-Gluc, pH 9 for MC, and pH 7 for X-InP.
    2. Prepare stock solutions of the substrates in the pH adjusted HEPES buffer at concentrations of 3 mM (CPRG), 62.5 mM (X-Gluc), 15 mM (MC), 100 mM (X-InP). Protect the stock solutions from light.
    3. Place the µPADs inside a sterile Petri dish, then imbed the µPAD microspot with 24 µl of each substrate stock solution.

4. Detection and Data Analysis

  1. Detection
    1. Add 6 µl of the enriched sample to each appropriate µPAD microspot contained in a Petri dish.
    2. Place the cover back on the Petri dish and seal it with Parafilm.
    3. Incubate the sample with the µPAD at 37 °C for up to 3 hr to allow for color development and drying of the microspots.
  2. Visual Examination of the Results
    1. Perform detection by simple visual inspection of the color changes of the µPADs.
      NOTE: Typically, strong reactions that produce definitive color changes are expected following 18-24 hr of enrichment, which should obviate the need for further clarification and should be considered positive.
    2. Determine the presence of an E. coli positive sample by observing microspots imbedded with CPRG change from yellow to red-violet and microspots imbedded with X-Gluc change from colorless to blue-green.
    3. Determine the presence of a L. monocytogenes positive sample by observing microspots imbedded with X-InP change from colorless to indigo.
    4. Determine the presence of a Salmonella spp. positive sample by observing microspots imbedded with MC change from colorless to purple-mauve.
  3. Software Aided Data Analysis
    NOTE: Conducted to clearly determine whether weak reactions are positive or negative and to enable a semi-quantitative analysis of the results.
    1. Allow the µPADs to fully dry.
    2. Scan the µPAD using a flat-bed scanner.
    3. Use ImageJ software to process the image.
      1. "Open” scanned image to be analyzed in ImageJ located under the “File” tab on the main menu (or press “Clt+O”).
      2. Invert the image selecting “Invert” located under the “Edit” tab on the main menu (or press “Clt+Shift+I”).
      3. Use the “Analyze” tab on the main menu and select “Set Measurements…” to select the reported measurements analyzed.
      4. Make sure that the “Mean grey intensity,” “Limit to threshold,” and “Display label” boxes are checked, and press “OK.” This sets how the software analyzes each area selected and how it reports it.
      5. Use the “Oval” tool to draw a circle that outlines the area that you want to measure within.
      6. Under the “Analyze” tab select “Measure,” (or press “Clt+M”). The software will measure the average grey intensity within the area defined and report it in a pop-up screen that can be copied and pasted to excel for further analysis.
        NOTE: For more accurate analyses, at least two technical replicates of each sample should be performed.

Résultats

As described in this protocol, concentration of bacteria using the MMS (Figure 1) can be performed within approximately 15-20 min. The MMS in constructed from acrylonitrile butadiene styrene (ABS) in two separate components; a lid and a cartridge both with an integrated spigot assembly into which a cylindrical cheesecloth swab is inserted (Figure 1A). Both components are then screwed together forming the MMS (Figure 1B). MMS-based processing is driven by a battery-powere...

Discussion

This protocol describes an integrated method for detecting E. coli, Salmonella spp., and L. monocytogenes in agricultural water. Here, MMS concentration of bacteria from large volumes (10 L) of agricultural water, is coupled with bacterial enrichment, and bacterial-indicative colorimetric detection using µPADs. The MMS procedure can cope with high particulate content in the water samples while concentrating the bacteria 10-fold, is robust and simple enough for field applications by minimal...

Déclarations de divulgation

The authors have nothing to disclose.

Remerciements

We gratefully acknowledge funding for this project from the USDA National Institute of Food and Agriculture grants 2009-01208 and 2009-01984.

matériels

NameCompanyCatalog NumberComments
Agricultural waterIrrigation water, produce wash water, well water, etc.
Vinyl tubingWilmarBN-CVT1005 1/4" inner diameter,  3/8" outer diameter, available at:  http://www.wilmar.com
Modified Moore Swab cartridge Lumiere Diagnostics11 ½ cm in length and 4 ½ cm in width, available at:  http://www.lumierediagnostics.com.  Alternativelly, a non-disposable version of the cartridge can be used (refer to the text)
CheeseclothChesapeake Wiper & Supply, Inc.CC90Grade #90, 44 x 36 weave, available at:  www.raglady.com
Household BleachVariousSodium hypochlorite concentration approx. 6%
Sodium thiosulphate 5-hydrateMallinckrodt Baker Inc8100-04
ManifoldBuilt in-houseOptional, device can be constructed from PVC pipes and appropriate fittings
Peristaltic pumpMicron MetersRPP1300Available at:  http://www.micronmeters.com
Serological pipetteVariousDisposable, 10 ml
Universal preenrichment brothDifco223510
Buffered peptone waterDifco218105
Salmonella supplementBiomérieux Industry42650http://www.biomerieux-usa.com
VIDAS UP Listeria (LPT) BrothBiomérieux Industry410848http://www.biomerieux-usa.com
VancomycinSigma-Aldrich861987http://www.sigmaaldrich.com
Pipet-AidVariousDrummond DP-110 used here
Shaking incubatorVariousExcella E25, New Brunswick Scientific used here
Micropipette Various10 μl, 1 ml
Micropipette tipsVariousBarrier, 10 μl, 1 ml
1.5 microcentrifuge tubesVariousRNase- and DNase-free
Probe sonicatorQ Sonica LLCXL-2000 series
µPADsAvant Wax printed 7 mm diameter circles, with 4 pt line thickness. Contact Dr. Charles Henry for additional information
HEPES [N-(2-Hydroxyethyl)piperazine-N′-2-ethanesulfonic acid]Sigma-AldrichH3375
Bovine serum albuminSigma-AldrichA8022
Chlorophenol red-galactopyranoside (CPRG)Sigma-Aldrich59767
5-Bromo-4-chloro-3-indolyl-β-D-glucuronide (X-Gluc)Sigma-AldrichB8174
5-bromo-6-chloro-3 indolylcaprylate (magenta caprylate) Sigma-Aldrich53451
5-Bromo-4-chloro-myo-inositol phosphate (X-InP) Sigma-Aldrich38896
Petri dishes, polystyrene 100 mm by 15 mmVariousSterile
Flat bed scannerVariousXerox USB scanner
ImageJ softwareNational Institutes of Healthhttp://rsb.info.nih.gov/ij/

Références

  1. . . Guidance for industry: Guide to minimize microbial food safety hazards for fresh fruits and vegetables. , (1998).
  2. Bisha, B., Pérez-Méndez, A., Danyluk, M. D., Goodridge, L. D. Evaluation of Modified Moore swabs and continuous flow centrifugation for concentration of Salmonella and Escherichia coli O157:H7 from large volumes of water). J Food Prot. 74, 1934-1937 (2011).
  3. Sbodio, A., Maeda, S., Lopez-Velasco, G., Suslow, T. V. Modified Moore swab optimization and validation in capturing E. coli O157:H7 and Salmonella enterica in large volume field samples of irrigation water. Food Res Int. 51, 654-662 (2013).
  4. McEgan, R., et al. Detection of Salmonella spp. from large volumes of water by modified Moore swabs and tangential flow filtration. Lett Appl Microbiol. 56, 88-94 (2013).
  5. . . Solicitation Number: FDA-SS-1116253. , (2013).
  6. Jokerst, J. C., et al. Development of a paper-based analytical device for colorimetric detection of select foodborne pathogens. Analytical Chemistry. 84, 2900-2907 (1021).
  7. Martinez, A. W., Phillips, S. T., Butte, M. J., Whitesides, G. M. Patterned paper as a platform for inexpensive, low-volume, portable bioassays. Angew Chem Int Edit. 46, 1318-1320 (2007).
  8. Martinez, A. W., Phillips, S. T., Wiley, B. J., Gupta, M., Whitesides, G. M. FLASH: A rapid method for prototyping paper-based microfluidic devices. Lab on a Chip. 8, 2146-2150 (1039).
  9. Abe, K., Suzuki, K., Citterio, D. Inkjet-printed microfluidic multianalyte chemical sensing paper. Analytical Chemistry. 80, 6928-6934 (1021).
  10. Cheng, C. M., et al. Millimeter-scale contact printing of aqueous solutions using a stamp made out of paper and tape. Lab on a Chip. 10, 3201-3205 (1039).
  11. Lu, Y., Shi, W. W., Jiang, L., Qin, J. H., Lin, B. C. Rapid prototyping of paper-based microfluidics with wax for low-cost, portable bioassay. Electrophoresis. 30, 1497-1500 (2009).
  12. Charles, S., Henry, L. D. G., Jana, C. Jokerst Rapid detection of pathogens using paper devices. US patent. , (2012).
  13. Bisha, B., et al. T10-06 Colorimetric paper-based detection of Salmonella spp. and Escherichia coli from artificially contaminated irrigation river water. , (2012).

Réimpressions et Autorisations

Demande d’autorisation pour utiliser le texte ou les figures de cet article JoVE

Demande d’autorisation

Explorer plus d’articles

Keywords Colorimetric DetectionPaper based DetectionEscherichia ColiSalmonella SppListeria MonocytogenesAgricultural WaterModified Moore SwabsEnrichmentPaper based Analytical DevicesColorimetric SubstratesBacterial EnzymesMicrobiological Quality

This article has been published

Video Coming Soon

JoVE Logo

Confidentialité

Conditions d'utilisation

Politiques

Recherche

Enseignement

À PROPOS DE JoVE

Copyright © 2025 MyJoVE Corporation. Tous droits réservés.