Method Article
We describe methods for large-scale recording of multiple single units and local field potential in behaving rodents with silicon probes. Drive fabrication, probe attachment to the drive and probe implantation processes are illustrated in sufficient details for easy replication.
A major challenge in neuroscience is linking behavior to the collective activity of neural assemblies. Understanding of input-output relationships of neurons and circuits requires methods with the spatial selectivity and temporal resolution appropriate for mechanistic analysis of neural ensembles in the behaving animal, i.e. recording of representatively large samples of isolated single neurons. Ensemble monitoring of neuronal activity has progressed remarkably in the past decade in both small and large-brained animals, including human subjects1-11. Multiple-site recording with silicon-based devices are particularly effective because of their scalability, small volume and geometric design.
Here, we describe methods for recording multiple single neurons and local field potential in behaving rodents, using commercially available micro-machined silicon probes with custom-made accessory components. There are two basic options for interfacing silicon probes to preamplifiers: printed circuit boards and flexible cables. Probe supplying companies (http://www.neuronexustech.com/; http://www.sbmicrosystems.com/; http://www.acreo.se/) usually provide the bonding service and deliver probes bonded to printed circuit boards or flexible cables. Here, we describe the implantation of a 4-shank, 32-site probe attached to flexible polyimide cable, and mounted on a movable microdrive. Each step of the probe preparation, microdrive construction and surgery is illustrated so that the end user can easily replicate the process.
1. Construction of the microdrive
All drives are made from the same basic elements: a moving part, which carries the electrode and a fixed part, which is anchored to the skull. An ideal microdrive allows smooth but long enough travel of the electrode in multiple small steps, is sturdy enough to prevent accidental movement of the electrode, easy to manipulate by the experimenter without interfering with the animal's behavior, small in size and light in weight. As a result of these competing requirements, different drives suite different applications.
Only 4 parts are needed to build our basic drive: a brass flat head screw, a matching nut, a plastic bridge prepared from a single row pin header and two custom-cut brass plates.
2. Preparing the silicon probe
Before fixing the probe to the drive, add extra insulation to the bonding area of the probe to prevent cerebrospinal fluid (CSF) or humidity from producing short-circuits:
To ensure that the recording sites are devoid of any debris, the probe tips need to be cleaned:
Before fixing the probe to the drive, the impedance of each recording site should be checked:
3. Affixing the probe to the microdrive
4. Preparing the skull
Prior to surgery, the reference and ground electrodes, and the parts of the on-head Faraday cage are prepared:
Surgical instruments and preparation are the same as used in many small animal surgeries. The entire surgery is done under deep isoflurane anesthesia, using aseptic conditions, according to NIH approved guidelines. Please note that the (mock) surgery shown in this video is for demonstration purposes only. For appropriate visibility and filming purposes, several preparatory steps, surgical precautions and postoperative procedures are not shown/visible or discussed.
Prior to surgery, all components and supplies should be sterilized, following appropriate procedures (see Guidelines for Survival Rodent Surgery; http://oacu.od.nih.gov/ARAC/surguide.pdf). During surgery, a sterile field on the skull is prepared and isolated by sterile drapes. At the end the surgery, a broad spectrum antibiotics is applied locally and a long-acting pain killer is given intramuscularly (e.g., buprenorphine, [Buprenex] 0.05 mg/kg). In addition, painkiller (e.g., Ibuprofen) is provided in the drinking water at approximately 60 mg/kg/24 hrs for 5 days. For proper surgical and anesthesia procedures, consult appropriate sources12.
5. Preparing the brain surface
6. Implanting the probe
At this stage, the density and orientation of cortical surface vessels are carefully evaluated. Stereotaxic coordinates should be adjusted, because the probe has to penetrate the brain in an area free from larger vessels.
For implantation, the drive assembly can be held with an alligator clip attached to the stereotaxic holder. Uninterrupted visibility of the brain surface and the tips of the probe are critical for successful penetration.
7. Building the on-head Faraday cage
8. Recording in the freely moving animal
9. Representative Results
Electrophysiological signals (local field potential and unit activity) vary depending on the recorded structure and the current behavior of the animal. Figure 1 shows examples of 32-channel CA1 hippocampal recordings while the rat is exploring an open field. Note the prominent 8 Hz (theta band) oscillation of the local field potential during exploration with superimposed spiking on multiple shanks and sites (examples of spikes indicated by arrowheads). To analyze neuronal unit activity, spikes are detected and sorted into single units using cluster analysis of their waveforms15-16.
Figure 1. CA1 Hippocampal recordings in the behaving rat using a 4 shanks x 8 sites silicon probe. Recordings are wideband and sampled at 20 000 Hz, which allows to study both local field potential oscillations (e.g. "theta" band 8 Hz rhythm) and neuronal spiking activity.
Table 1. Alternatives to reagents and equipment used. Please click here to see a larger version of this figure.
This movie illustrates the implantation procedure of silicon probes for chronic large-scale recordings in the behaving rat. Critical steps to ensure quality recordings of neuronal activity arise from the fragility of both biological (brain tissue) and technical (silicon probe) materials. Special care should be taken while handling the probe to avoid any contact of shanks with any remotely "hard" surface (for example, the shanks would break if one tried to implant them in the brain without removing the dura). Similarly, a...
No conflicts of interest declared.
Marie Curie International Outgoing Fellowship (European Union's FP/2007-2013 Grant Agreements #221834 and 254780), J.D. McDonnell Foundation, NSF Grant SBE 0542013, National Institutes of Health Grant NS034994, National Institute of Mental Health Grant MH5467 and the Howard Hughes Medical Institute (Janelia Farm Research Campus grant).
Name | Company | Catalog Number | Comments | |
Silicon probe Buzsaki32, 4 shanks x 8 sites. Packaging: flexible polyamide cable | Material | NeuroNexus Technologies | Probe: buzsaki32 Packaging: HC32 | Recording probe |
Round Brass Screw, 00-90 x 1/2 Round Brass Screws | Material | JIMorris | R0090B500 | Drive part |
Brass Hex Nut, 00-90 | Material | JIMorris | N0090B | Drive part |
Brass C260 Strip, ASTM-B36 Thickness: 0.025", Length: 12", Width: 1/2" | Material | Small Parts, Inc. | B000FMYU72 | Drive part |
Connector Header, pitch 2mm, male, single row, straigt, 36 positions | Material | Digi-Key | 2163S-36-ND | Drive part |
2-part Sylgard silicon Elastomer | Material | World Precision Instruments, Inc. | SYLG184 | To extra-insulate the probe |
Decon Contrad 70 Liquid Detergent | Reagent | Fisher Scientific | 04-355 Decon Laboratories No.:1002 | To clean the recording sites |
Impedance Conditioning Module | Equipment | FHC, Inc. | 55-70-0 | Impedance meter |
niPOD - 32 channels | Equipment | NeuroNexus Technologies | niPOD -32 | Impedance meter |
Grip Cement Industrial Grade | Material | Caulk Dentsply | 675571 (powder) 675572 (solvent) | Grip cement |
1,1’-dioctadecyl-3,3,3’,3’-tetramethylindocarbocyanine perchlorate (’DiI’; DiIC18(3)) | Reagent | Invitrogen | D282 | To stain the probe track in the brain |
Stainless Steel Machine Screw, Binding Head, Slotted Drive, #00-90, 1/8" | Material | Small Parts, Inc. | MX-0090-02B | Ground and reference screws |
Magnet wire, 20G, nylon-polyurethane coating, MW80 | Material | Small Parts, Inc. | B000IJYRP2 | Ground and reference wire |
Stainless Steel Machine Screw, Binding Head Slotted Drive, #000-120, 1/16" | Material | Small Parts, Inc. | MX-000120-01B | Anchor screws |
N-3 All purpose Flux Liquid | Reagent | La-Co (Markal) | 23512 | Allows to solder stainless-steel |
MicroGrid Precision Expanded Copper | Material | Dexmet | 3 CU6-050 FA | Copper mesh for on-head Faraday cage |
C&B-METABOND Quick! Cement System - Dentin Activator | Material | Parkell | S380 | |
C&B-METABOND Quick! Cement System - Dental cement | Material | Parkell | S380 | |
Sharp point tungsten needle and holder | Tool | Roboz Surgical Instruments Co. | RS-6064 and RS-6061 | To make the hook to lift the dura |
Carbide Bur HP 1/4 | Tool | Henry Schein | 9990013 | |
Paraffin (Granules) | Material | Fisher Scientific | P31-500 | |
Mineral Oil, Light (NF/FCC) | Material | Fisher Scientific | O121-1 | |
GC ELECTRONICS 10-114 2-Part Epoxy Adhesive | Material | Newark Inc | 00Z416 | |
Type 1 LITZ 21 AWG 40/36 Red Single Polyurethane-Nylon (MW80-C) TO 0.041"+/-0.002" OD | Material | New England Biolabs | N28-36E-400-2 | To make the cable between the headstage and the amplifier |
32-channel Very Large Scale Integration headstage, 20x gain | Equipment | Plexon | HST/32V-G20 | Headstage |
Zapytaj o uprawnienia na użycie tekstu lub obrazów z tego artykułu JoVE
Zapytaj o uprawnieniaThis article has been published
Video Coming Soon
Copyright © 2025 MyJoVE Corporation. Wszelkie prawa zastrzeżone