Summary

This protocol presents the clinical application of a 24 G cannula and 3-0 polypropylene suture as a simple and effective method for the exploration of the vas deferens.

Abstract

The goal of this article is to present the application of a 24 G cannula and 3-0 polypropylene suture as a simple method for the exploration of the vas deferens. During the exploration of the vas deferens, a 24 G cannula needle was used to puncture it. The fluid in the smear confirmed the presence of sperm, to determine whether or not there was concomitant obstruction at the junction of the epididymis and the vas deferens. Then, a 3-0 polypropylene suture (this suture specification has the advantages of a smooth surface, robust quality, and can be passed through a 24 G cannula needle) was passed through the cannula needle to probe the location of the obstructed site. With this technique, exploration of the vas deferens could be more targeted and accurate.

Introduction

Microsurgical vasovasostomy (MVV) is a common treatment for vas deferens obstruction after herniorrhaphy in childhood1,2. The site of obstruction cannot be identified preoperatively, and it is not clear whether sperm are present in the vas deferens or not. This may lead to difficulty in selecting the incision and injury to the vas deferens during semi-open exploration, which decreases the success rate of anastomosis, prolongs the operation time, and increases the risk of abdominal exploration3,4.

Injury to the vas deferens ....

Protocol

All methods described here were approved by the Ethics Committee of Union Hospital Tongji Medical College, Huazhong University of Science and Technology. We obtained the patient's consent to use his surgical footage as a video after the procedure.

1. Instruments for operation

  1. Ensure the availability of a surgical microscope system, microsurgical instrument, and microscopic bipolar electrocoagulation.

2. Preparation for o.......

Representative Results

There were 67 patients enrolled in the study. As shown in Table 1, the mean age of the patients was 28.8 ± 3.7 years (range: 23-45 years). The time since herniorrhaphy was 24.5 ± 3.2 years (range: 21-43 years). The female partners were 25.2 ± 3.2 years (range: 23-42 years) years old. A total of 11 (16.4%) patients had pain in the scrotum. Four patients (6.0%) were underweight (BMI < 18.5 kg/m2), 53 (79.1%) had normal weight (BMI 18.5-24.9 kg/m2), eight (11.9%) wer.......

Discussion

As mentioned before, the location of the vas deferens stump cannot be determined at the inguinal incision, which requires exploration of the original inguinal incision. In this study, we can use this simple operation to determine the site of obstruction and make surgical decisions. If the site of obstruction is in the original incision, MVV can be considered. If the vas deferens injury is not found in the inguinal canal, we can use lapa-VV or SV.

When pasty fluid without sperm was found and th.......

Acknowledgements

We thank ZHZ for the conception and design of the study. JW and YPZ performed and supervised the operation. YH, YBX, SL contributed to data analysis. JW and WJL prepared the draft of the video. All authors participated in the revision of the manuscript. All authors read and approved the final manuscript.

....

Materials

NameCompanyCatalog NumberComments
0.9% sodium chloride solutionGuangdong Otsuka Pharmaceutical Co. LTD 21M1204 Inject into the vas deferens
1% iodophorGuangzhou Qingfeng Disinfection Products Co., LTD Q/QFXD2Skin disinfection
24G cannula needleSuzhou Linhua Medical Instrument Co., LTD20193141896Size:24G, Type:Pen type, with wings, with injection port, Y type
3-0 monofilament polypropyleneCovidien Medical Equipment international trading (Shanghai) Co., LTDDOL2861yTaper Point, Size 3-0, Blue, 36", Needle V-20, 1/2 Circle
5 mL syringe Kindly Medical, Shanghai K20210826Inject 0.9% sodium chloride solution into the vas deferens
F16 Catheter Guangzhou Weili Co., Ltd 20190612Drainage of urine
micro haemostatic forcepsShanghai Medical Instrument (Group) Co., LTD.W40350Used in surgical procedures
micro scissorsShanghai Medical Instrument (Group) Co., LTD.WA1010Used in surgical procedures
micro tweezersShanghai Medical Instrument (Group) Co., LTD.WA1020Used in surgical procedures
Olympus microscopeOlympus CorporationScipu0011584×N.A.0.10 W.D.22.0mm     10×N.A.0.25 W.D.10.5mm       40×N.A.0.65 W.D.0.56mm     100×N.A.1.25 W.D.0.13mm 
Operating microscope system Carl Zeiss Co., Ltd OPMI VARIO 700

References