A subscription to JoVE is required to view this content. Sign in or start your free trial.
This protocol presents the clinical application of a 24 G cannula and 3-0 polypropylene suture as a simple and effective method for the exploration of the vas deferens.
The goal of this article is to present the application of a 24 G cannula and 3-0 polypropylene suture as a simple method for the exploration of the vas deferens. During the exploration of the vas deferens, a 24 G cannula needle was used to puncture it. The fluid in the smear confirmed the presence of sperm, to determine whether or not there was concomitant obstruction at the junction of the epididymis and the vas deferens. Then, a 3-0 polypropylene suture (this suture specification has the advantages of a smooth surface, robust quality, and can be passed through a 24 G cannula needle) was passed through the cannula needle to probe the location of the obstructed site. With this technique, exploration of the vas deferens could be more targeted and accurate.
Microsurgical vasovasostomy (MVV) is a common treatment for vas deferens obstruction after herniorrhaphy in childhood1,2. The site of obstruction cannot be identified preoperatively, and it is not clear whether sperm are present in the vas deferens or not. This may lead to difficulty in selecting the incision and injury to the vas deferens during semi-open exploration, which decreases the success rate of anastomosis, prolongs the operation time, and increases the risk of abdominal exploration3,4.
Injury to the vas deferens ....
All methods described here were approved by the Ethics Committee of Union Hospital Tongji Medical College, Huazhong University of Science and Technology. We obtained the patient's consent to use his surgical footage as a video after the procedure.
1. Instruments for operation
2. Preparation for o.......
There were 67 patients enrolled in the study. As shown in Table 1, the mean age of the patients was 28.8 ± 3.7 years (range: 23-45 years). The time since herniorrhaphy was 24.5 ± 3.2 years (range: 21-43 years). The female partners were 25.2 ± 3.2 years (range: 23-42 years) years old. A total of 11 (16.4%) patients had pain in the scrotum. Four patients (6.0%) were underweight (BMI < 18.5 kg/m2), 53 (79.1%) had normal weight (BMI 18.5-24.9 kg/m2), eight (11.9%) wer.......
As mentioned before, the location of the vas deferens stump cannot be determined at the inguinal incision, which requires exploration of the original inguinal incision. In this study, we can use this simple operation to determine the site of obstruction and make surgical decisions. If the site of obstruction is in the original incision, MVV can be considered. If the vas deferens injury is not found in the inguinal canal, we can use lapa-VV or SV.
When pasty fluid without sperm was found and th.......
We thank ZHZ for the conception and design of the study. JW and YPZ performed and supervised the operation. YH, YBX, SL contributed to data analysis. JW and WJL prepared the draft of the video. All authors participated in the revision of the manuscript. All authors read and approved the final manuscript.
....Name | Company | Catalog Number | Comments |
0.9% sodium chloride solution | Guangdong Otsuka Pharmaceutical Co. LTD | 21M1204 | Inject into the vas deferens |
1% iodophor | Guangzhou Qingfeng Disinfection Products Co., LTD | Q/QFXD2 | Skin disinfection |
24G cannula needle | Suzhou Linhua Medical Instrument Co., LTD | 20193141896 | Size:24G, Type:Pen type, with wings, with injection port, Y type |
3-0 monofilament polypropylene | Covidien Medical Equipment international trading (Shanghai) Co., LTD | DOL2861y | Taper Point, Size 3-0, Blue, 36", Needle V-20, 1/2 Circle |
5 mL syringe | Kindly Medical, Shanghai | K20210826 | Inject 0.9% sodium chloride solution into the vas deferens |
F16 Catheter | Guangzhou Weili Co., Ltd | 20190612 | Drainage of urine |
micro haemostatic forceps | Shanghai Medical Instrument (Group) Co., LTD. | W40350 | Used in surgical procedures |
micro scissors | Shanghai Medical Instrument (Group) Co., LTD. | WA1010 | Used in surgical procedures |
micro tweezers | Shanghai Medical Instrument (Group) Co., LTD. | WA1020 | Used in surgical procedures |
Olympus microscope | Olympus Corporation | Scipu001158 | 4×N.A.0.10 W.D.22.0mm 10×N.A.0.25 W.D.10.5mm 40×N.A.0.65 W.D.0.56mm 100×N.A.1.25 W.D.0.13mm |
Operating microscope system | Carl Zeiss Co., Ltd | OPMI VARIO 700 |