A subscription to JoVE is required to view this content. Sign in or start your free trial.
A modified no-scalpel vasectomy technique reduces the postoperative recanalization rate. This protocol describes a modified no-scalpel vasectomy technique that can reduce the postoperative recanalization rate.
No-scalpel vasectomy (NSV) is a commonly used contraceptive method for males. In previous applications of this surgical method, issues such as knot detachment and postoperative recanalization resulted in a reduced contraceptive success rate after vasectomy. This new technique innovatively modifies the ligation procedure during NSV to address knot detachment and postoperative recanalization. Two ligations of the testicular end of the vas deferens and one ligation of the abdominal end are completed before transection of the vas deferens. A fourth ligation of the abdominal end is performed using the suture tails of the third ligature of the testicular end after transection of the vas deferens. The fifth ligation of the abdominal end is performed using the suture tails of the first ligature of the testicular end. These modifications strengthen the ligations and reduce the postoperative recanalization rate. Additionally, the two stumps are gathered together, creating better conditions for a possible vasovasostomy in the future, thereby achieving overall better outcomes with vasectomy.
Vasectomy is a surgical sterilization procedure for men to prevent future fertility1,2,3. It is equally effective as tubal ligation for preventing pregnancy but is simpler, safer, faster, and less expensive4. This type of surgery has lower implementation requirements, and more than 80% of vasectomies are performed in the office5. Since 1971, when Li Shunqiang et al. performed the first modified vasectomy (the no-scalpel vasectomy or NSV)6, the procedure has advanced significantly. The invention of the ext....
The surgical method described in this paper has been approved by the Ethics Committee of the West China Second University Hospital of Sichuan University, and the use of patient surgical videos has been authorized. Informed consent was obtained from the patients, and their data was used for presentation. The consumables and equipment used for this study are listed in the Table of Materials.
1. Preparation for operation
From January 2021 to August 2023, 58 vasectomies were performed at this hospital. All 58 patients had at least one child with their spouses before undergoing vasectomy. Although the modification involved more surgical steps compared to NSV, it did not significantly increase the difficulty of the operations. As a result, all 58 vasectomies were successfully completed without any unsuccessful operations. Patients were followed up regularly by telephone. Follow-up ended when the PVSA demonstrated less than 2,00,000 sperm/mL.......
The gold standard for vasectomy is ligation with mucosal cautery13, but not all operating rooms have electrocautery equipment. Therefore, this modification technique achieved ideal surgical results by ligating the vas deferens five times with non-absorbable silk sutures, without the need for electrocautery equipment. It has been documented that applying excessive pressure to the vas with sutures can create ischemia and sloughing of the ligated stump, leading to recanalization. This may explain som.......
The authors would like to thank the West China Second University Hospital of Sichuan University for providing cases and medical records related to this work. There is no funding support for this study.
....Name | Company | Catalog Number | Comments |
3-0 silk braided non-absorbable suture | Johnson & Johnson Medical (China) Ltd. | SA84G | 15 × 60cm |
5-0 Coated VICRYL Plus (Polyglactin 910) Synthetic Absorbable Suture | Ethicon.Inc. | VCP433H | 13 mm 1/2c (70cm) |
Dissecting clamp | Xinhua Surgical Instruments Co., Ltd. | ZJ197R | 125 mm |
Extracutaneous vas deferens fixation ring clamp | Xinhua Surgical Instruments Co., Ltd. | ZJ196R | 140 mm |
Scissors | Xinhua Surgical Instruments Co., Ltd. | ZC344R | 140 mm |
SPSS 23.0 | IBM |
Explore More Articles
This article has been published
Video Coming Soon
ABOUT JoVE
Copyright © 2024 MyJoVE Corporation. All rights reserved