A subscription to JoVE is required to view this content. Sign in or start your free trial.
* These authors contributed equally
Presented here is a quantitative, clinical balance assessment method suitable for stroke patients with balance disorders.
In patients with stroke, damage to the central nervous system (CNS) can affect the postural stability and increase the risk of falling. Therefore, accurately assessing the balance is important to understand the type, extent, and causes of balance deficit, and to identify individualized interventions. Clinical assessment methods for balance function can be broadly divided into observation, scale assessment, and balance instrument testing. Here, a clinical protocol is presented for static and dynamic balance assessment in stroke patients, which includes three semiquantitative balance function scale assessments (i.e., Berg Balance Scale, Timed Up and Go Test, and Fugl-Meyer Assessment) and three quantitative instrumental balance evaluation (i.e., Stability Assessment Module, Proprioceptive Assessment Module, and Limit of Stability Module). It is recommended that clinicians consider the use of both classic clinical balance scales and instrumental balance measurements when assessing stroke patients to improve the accuracy of assessments, leading to a better individualized treatment plan.
The human body can maintain posture stability under various conditions, including internal and external disturbances1. Balance relies on sensory input, integration of the central nervous system (CNS), and motor control2. In patients with stroke, damage to the CNS can affect the ability to maintain balance3. Postural instability is an important risk factor for falls4. Approximately 70% of patients experience a fall in the first year after stroke, often with serious consequences, such as hip fracture in elderly patients5,6<....
The clinical project was approved by the Medical Ethics Association of the Fifth Affiliated Hospital of Guangzhou Medical University and has been registered at the China Clinical Trial Registration Center (No. ChiCTR1900021291) with the title “The mechanism and effect of Pro-kin system training on static and dynamic balance”.
1. Participant recruitment
Results from nine stroke patients with balance deficits are shown. The average age of the nine patients recruited in our study was 52.7 years; all of them were male. Four suffered from right hemiplegia. The average FIM-LE, TUG, and BBS values were 23.9 points, 31.8 s, and 46.8 points, respectively. The other demographic characteristics (BMI, stroke type, and onset time) are shown in Table 2. Each item score and the total scores of the BBS assessment of each of the nine stroke patients are shown in
Described is a clinical protocol for static and dynamic balance assessment in stroke patients that includes three semiquantitative balance function scale assessments (BBS, TUG, and FMA-LE) and three models of quantitative instrumental balance evaluation (Stability Assessment, Proprioceptive Assessment, and Limit of Stability). The design of this protocol was based on five main points.
First, the BBS is a 14-function-task on a 5-point scale that semiquantitatively assesses static and dynamic ba.......
The author thanks graduate student Zhencheng Guan, Wude Chen, Haidong Huang, and Qinyi Li (Guangzhou Medical University) for data collection. This study was supported by the National Natural Science Foundation for Young Scientists of China (Grant No.81902281); General Guidance Project of Guangzhou Health and Family Planning Commission (Grant No.20191A011091 and
No.20201A011108); Science and Technology Innovation Project for College Students in Guangzhou Medical University (Grant No. 2018A053), Guangzhou Key Laboratory Fund (Grant No.201905010004) and Major Industrial Technology Project of Guangzhou Science and Technology Bureau (Grant No.201902020001).
Name | Company | Catalog Number | Comments |
Electric Lifting Bed | Guangzhou Yikang Medical Equipment Industrial Co., Ltd | YK-8000 | Required for Fugl-Meyer assessment |
Percussion hammer | ICARE-MEDICAL Co., Ltd. | CRT-104 | Required for Fugl-Meyer assessment |
Prokin Balance System | Tecnobody .S.r.l, Italy | ProKin 252 | Balance evaluation and training system |
Ruler | M&G Chenguang Stationery Co.,Ltd. | AHT99112 | Required for Berg Balance Scale assessment |
Stopwatch | 95,Shenzhen Junsd Industrial Co., Ltd have been striven all the years de | JS-306 | Required for Berg Balance Scale assessment |
Explore More Articles
This article has been published
Video Coming Soon
ABOUT JoVE
Copyright © 2024 MyJoVE Corporation. All rights reserved