A subscription to JoVE is required to view this content. Sign in or start your free trial.
This study describes the application of the O-arm intraoperative imaging system in odontoid fractures.
Odontoid fractures account for a large proportion of cervical spine fractures in the elderly, causing pain in the occiput and the back of the neck and restricting neck movement. Anterior cervical screw fixation is a common surgical procedure to treat odontoid fractures. Due to the special location and complex anatomy of the odontoid, surgeons need to perform intraoperative fluoroscopies repeatedly to ensure correct screw position and avoid damage to the peripheral nerves and vessels of the odontoid. The traditional anterior cervical screw fixation is usually conducted with the assistance of a C-arm. However, compared to the C-arm, an O-arm intraoperative imaging system can provide 3D images during surgery, which improves the accuracy of screw placement. This study retrospectively analyzed patients with anterior cervical odontoid fractures treated in our hospital. The application of the O-arm intraoperative imaging system for assisting screw placement in the treatment of odontoid fractures can reduce intraoperative blood loss, operation time, and trauma to the patients.
Odontoid fracture is a common form of cervical spine fracture, accounting for approximately 20% of all cervical spine fractures. Odontoid fracture mainly occurs in adults over the age of 651. Odontoid process displacement resulting from an external force acting on the cervical spine is the main cause of odontoid process fractures. The main symptoms of odontoid fracture are pain in the occiput and the back of the neck and immobility. According to Anderson's classification2, odontoid fractures can be divided into three types. Type I and type III odontoid fractures can achieve satisfactory results with conservative trea....
This study has been approved by the Ethics Committee of the Third Hospital of Hebei Medical University. The patients signed informed consent, and the patients consented to film and allowed the investigators to use their surgical data. A total of 40 patients were included in this study.
1. Preoperative preparation
Anterior cervical screw fixations were performed in 40 patients with odontoid fractures, of whom 21 patients underwent surgeries with the assistance of the O-arm intraoperative imaging system (Group O), and 19 patients underwent surgeries with the assistance of the C-arm (Group C). Data are presented as mean (± SD). The average age of Group O was 42.86 (± 10.36) years, while the average age of Group C was 41.05 (± 9.83) years. There was no significant difference in age between the two groups of patients. B.......
Odontoid fractures are usually caused by violent injury; common symptoms are pain and limited mobility. Some patients also experience nerve compression symptoms. In some patients, the degree of fracture displacement is relatively large, and the fracture fragments compress the spinal cord and cause symptoms of paraplegia and neuralgia. Some patients with odontoid fractures also have symptoms of hand weakness and difficulty in walking. Type II odontoid fractures have poor self-healing potential and often require surgical t.......
None.
....Name | Company | Catalog Number | Comments |
Bipolar electrocoagulation tweezers | Juan'en Medical Devices Co.Ltd | BZN-Q-B-S | 1.2 mm x 190 mm |
Cannulated Lag Screws | Medtronic Sofamor Danek USA ,Inc | 873-146 | 4.0 mm x 46 mm |
High frequency active electrodes | ZhongBangTianCheng | GD-BZ | GD-BZ-J1 |
Laminectomy rongeur | Qingniu | 2054.03 | 220 x 3.0 x 130° |
Laminectomy rongeur | Qingniu | 2058.03 | 220 x 5.0 x 130° |
Pituitary rongeur | Qingniu | 2028.01 | 220 x 3.0 mm |
Pituitary rongeur | Qingniu | 2028.02 | 220 x 3.0 mm |
Surgical drainage catheter set | BAINUS MEDICAL | SY-Fr16-C | 100-400 mL |
Surgical film | 3L | SP4530 | 45 x 30 cm |