A subscription to JoVE is required to view this content. Sign in or start your free trial.
The protocol described here provides the basics of spine sonoanatomy and a quick, straightforward method for performing ultrasound-guided neuraxial anesthesia. Additionally, two handheld devices that enhance portability are presented, one of which uses pattern recognition software to aid in epidural space localization.
Neuraxial anesthesia is one of the few remaining forms of regional anesthesia that relies on palpation and tactile feedback techniques to facilitate catheterization into the epidural space. Over two decades ago, spine ultrasonography was demonstrated to provide reliable guidance for locating the epidural space. Compared to the palpation technique, preprocedural ultrasonography has been shown to result in fewer needle punctures and fewer traumatic procedures, particularly in patients with abnormal or distorted spine anatomy (e.g., scoliosis, obesity). Despite its utility, the ultrasound-guided neuraxial technique is still marginally used, even for patients with abnormal anatomy. Some experts attribute this to cost, a relatively high success rate without ultrasound, and a lack of technical expertise, which is often tied to formal education and regular practice. Several proponents of the ultrasound technique emphasize that proficiency requires practice on patients with normal spine anatomy, though this training may not be as challenging as once thought. This protocol was designed to help all providers learn the basics of lumbar spine anatomy and how to apply this knowledge clinically. Through a series of videos, we will provide step-by-step instructions for performing neuraxial ultrasonography and offer practical tips for troubleshooting in cases of difficult anatomy.
Lumbar epidural analgesia provides the dual benefit of providing effective labor analgesia and the best way of avoiding the use of general anesthesia1. The latter has been associated with anesthetic and surgical complications as well as an increased risk of postpartum depression2,3. Hence, it is not surprising that anesthesiologists have evaluated many techniques over the years to decrease the incidence of epidural catheter failures. Several techniques (e.g., combined spinal and dural puncture epidural) evaluated over the years have been shown to reduce the incidence of epidural cathete....
All procedures involving human participants in the study were conducted in accordance with the ethical standards of the institutional guidelines for research and the 1964 Declaration of Helsinki, including its later amendments or comparable ethical standards. The protocol was developed based on input from previously published articles in the academic literature30,31,32. Imaging studies were conducted on the authors themselves fo.......
The main results from this research have focused on image quality and proficiency in performing ultrasound-guided neuraxial anesthesia. When comparing the quality of images from the BU to those of a mid-range ultrasound machine, it was determined that the former is a good alternative for obtaining spine anatomy images26. In terms of proficiency, in a prospective cohort analysis, first attempt success rate (defined as the number of skin needle punctures), number of needle passes (defined as the num.......
The main findings of this research are that the use of US-guided neuraxial anesthesia results in an overall increased first-attempt success. That is, fewer needle attempts and passes are needed to identify the epidural space29. The abovementioned findings are in agreement with those of several meta-analysis studies when comparing preprocedural US-guided neuraxial anesthesia to the landmark technique7,8,9<.......
One of the authors (Antonio Gonzalez) is conducting a research project that is funded by the Butterfly Network. This author has provided his opinion and helped with the creation of educational material for Rivanna Medical (work not funded by the company).
We thank our fellows and residents who encourage us to keep up with our ever-changing practice.
....Name | Company | Catalog Number | Comments |
ACCURO | Rivanna Medical | NA | Described throughout the manuscript as the automated device |
Butterfly iQ+ | Butterfly Network | iQ+ | Described throughout the manuscript as the handheld device |
Traditional ultrasound | SonoSite | SonositePX | Select a low-frequency (2-5 MHZ) curvilinear probe if utilizing a traditional ultrasound device. |
Request permission to reuse the text or figures of this JoVE article